Feasibility of continuous microvascular tissue oxygenation monitoring using discrete optical semiconductor devices

This study evaluates the potential for the use of low-cost discrete optical semiconductors, specifically light-emitting diodes (LEDs) and a photodiode, for non-invasive measurement of microvascular tissue oxygen saturation (StO<sub>2</sub>). StO<sub>2</sub> is a crucial biomarker in monitoring microvascular function and tissue viability. Spectrometer-based methods typically use complex and expensive equipment, with the cost per patient potentially amounting to hundreds of dollars. This study aims to provide understanding of tissue-light interaction with broader implications extending to applications such as photoplethysmography (PPG). Our approach involves a system that includes three specifically selected LEDs coupled with a photodiode, focusing on assessing microvascular StO<sub>2</sub>. The methodology includes several phases: in vitro calibration using a controlled deoxygenation process in a liquid tissue phantom, computational simulations to estimate the penetration depths of selected LED wavelengths, an analysis of the effects of variability in LED output on measurement accuracy, and a preliminary human study. Results from the in vitro experiments demonstrated a root mean square error of 3.9 StO<sub>2</sub>-% between a spectrometer reference and our technique. The human study including baseline, occlusion and post-occlusion StO<sub>2</sub> measurements in six volunteers resulted in 76.0, 52.6 and 77.5 StO<sub>2</sub>-%, respectively. Computational simulations confirmed the effective penetration of selected wavelengths into targeted microvascular layers. The intrinsic and external factors affecting the measurement accuracy were analyzed. The findings support the feasibility of a cost-effective, simplified, and effective system for continuous monitoring of microvascular tissue oxygenation.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2025-11-04
DOI
https://doi.org/10.1016/j.bios.2025.118163
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of continuous microvascular tissue oxygenation monitoring using discrete optical semiconductor devices

Tuukka Panula, Tarja Niemi, Matti Kaisti, Tomi Jaakola et al.
Biosensors and Bioelectronics
Optical Imaging and Spectroscopy Techniques
article

Feasibility of continuous microvascular tissue oxygenation monitoring using discrete optical semiconductor devices

Tuukka Panula, Tarja Niemi, Matti Kaisti, Tomi Jaakola, Inka Mustajoki
article en

Abstract

This study evaluates the potential for the use of low-cost discrete optical semiconductors, specifically light-emitting diodes (LEDs) and a photodiode, for non-invasive measurement of microvascular tissue oxygen saturation (StO<sub>2</sub>). StO<sub>2</sub> is a crucial biomarker in monitoring microvascular function and tissue viability. Spectrometer-based methods typically use complex and expensive equipment, with the cost per patient potentially amounting to hundreds of dollars. This study aims to provide understanding of tissue-light interaction with broader implications extending to applications such as photoplethysmography (PPG). Our approach involves a system that includes three specifically selected LEDs coupled with a photodiode, focusing on assessing microvascular StO<sub>2</sub>. The methodology includes several phases: in vitro calibration using a controlled deoxygenation process in a liquid tissue phantom, computational simulations to estimate the penetration depths of selected LED wavelengths, an analysis of the effects of variability in LED output on measurement accuracy, and a preliminary human study. Results from the in vitro experiments demonstrated a root mean square error of 3.9 StO<sub>2</sub>-% between a spectrometer reference and our technique. The human study including baseline, occlusion and post-occlusion StO<sub>2</sub> measurements in six volunteers resulted in 76.0, 52.6 and 77.5 StO<sub>2</sub>-%, respectively. Computational simulations confirmed the effective penetration of selected wavelengths into targeted microvascular layers. The intrinsic and external factors affecting the measurement accuracy were analyzed. The findings support the feasibility of a cost-effective, simplified, and effective system for continuous monitoring of microvascular tissue oxygenation.

Biosensors and BioelectronicsVol. 294
University of Turku (FI), Turku University of Applied Sciences (FI), Turku University Hospital (FI)
Openalex Percentile: Top 53%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.