Design of heat pump system for a railway train’s cabin applications utilizing R744 and R290

Abstract Among greenhouse gases, R-134a, commonly used in train HVAC systems, has a high global warming potential (GWP) of 1430. Korea is required to reduce R-134a usage by 80% by 2045, necessitating the development of eco-friendly alternatives. In this study, a heat pump system using the eco-friendly refrigerants R744 (CO₂) and R290 (propane) was designed, and the finned tube heat exchangers for trains were developed by using the EVAP-COND program. Commercial compressors were selected too. The R744 system was designed with a gas cooler outlet temperature of 35 ℃ and an evaporation temperature of 5 ℃ under transcritical operation, while the R290 system was designed with a condenser outlet temperature of 45 ℃ and an evaporation temperature of 0 ℃. The superheat values were set to 5 ℃ for R744 and 20 ℃ for R290. Performance comparison showed that the cooling COP of R744 was up to 18.9% higher than that of R290, while the COP of R290 was 3.8% lower than that of R-134a due to differences in compressor power consumption.

Authors

Institutions

Publication Details

Journal
International Journal of Air-Conditioning and Refrigeration
Published
2025-11-04
DOI
https://doi.org/10.1007/s44189-025-00082-2
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of heat pump system for a railway train’s cabin applications utilizing R744 and R290

H.R. Kim, Minji Kwon, Rin Yun
International Journal of Air-Conditioning and Refrigeration
Refrigeration and Air Conditioning Technologies
article

Design of heat pump system for a railway train’s cabin applications utilizing R744 and R290

H.R. Kim, Minji Kwon, Rin Yun
article en

Abstract

Abstract Among greenhouse gases, R-134a, commonly used in train HVAC systems, has a high global warming potential (GWP) of 1430. Korea is required to reduce R-134a usage by 80% by 2045, necessitating the development of eco-friendly alternatives. In this study, a heat pump system using the eco-friendly refrigerants R744 (CO₂) and R290 (propane) was designed, and the finned tube heat exchangers for trains were developed by using the EVAP-COND program. Commercial compressors were selected too. The R744 system was designed with a gas cooler outlet temperature of 35 ℃ and an evaporation temperature of 5 ℃ under transcritical operation, while the R290 system was designed with a condenser outlet temperature of 45 ℃ and an evaporation temperature of 0 ℃. The superheat values were set to 5 ℃ for R744 and 20 ℃ for R290. Performance comparison showed that the cooling COP of R744 was up to 18.9% higher than that of R290, while the COP of R290 was 3.8% lower than that of R-134a due to differences in compressor power consumption.

International Journal of Air-Conditioning and RefrigerationVol. 33(1)
Hanbat National University (KR), Korea Railroad Research Institute (KR)
Ministry of Science and ICT, South Korea
Openalex Percentile: Top 66%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.