Evaluation of the Safety and Efficacy of Transcatheter Closure of Perimembranous Ventricular Septal Defects with a Single Device Type: A Single-Centre Experience

<b>Background/Objective</b>: Ventricular septal defect (VSD) is the most common congenital heart anomaly, with the perimembranous subtype (pmVSD) being among the most prevalent forms. Surgical repair remains the gold standard for treatment; however, percutaneous closure has emerged as a promising alternative due to the availability of various occlusion devices. Each technique presents distinct advantages and limitations, particularly in terms of complications and long-term outcomes. We sought to evaluate the safety and mid-term outcomes of pmVSD closure employing the Nit-Occlud<sup>®</sup> Le VSD Coil within a single-centre, single-team setting. <b>Methods</b>: Of the 55 patients hospitalised for pmVSD closure, 45 children underwent the procedure with the Nit-Occlud<sup>®</sup> Le VSD device. Relevant clinical and defect-related data were collected during hospitalisation and throughout follow-up. <b>Results</b>: Among 45 patients, successful coil implantation was achieved in 41 cases (91.1%). Periprocedural complications occurred in 8 patients (17.8%), including haemolysis, transient atrioventricular block, aortic valve injury, transient ST-segment elevation and supraventricular tachycardia. Two of these complications (4.4%) were classified as severe. The occurrence of complications was significantly associated with the type of VSD shunt (<i>p</i> = 0.03). <b>Conclusions</b>: Transcatheter closure of pmVSD using the Nit-Occlud<sup>®</sup> Lê VSD Coil in young children is a feasible and safe option with careful patient selection. Patients with type C pmVSD appear to benefit the most. Nevertheless, potential complications, including haemolysis and aortic valve injury, require close monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-11-04
DOI
https://doi.org/10.3390/jcm14217822
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Safety and Efficacy of Transcatheter Closure of Perimembranous Ventricular Septal Defects with a Single Device Type: A Single-Centre Experience

Wojciech Tarała, Oksana Trębacz, Robert Sabiniewicz, Jacek Podlewski et al.
Journal of Clinical Medicine
Congenital Heart Disease Studies
article

Evaluation of the Safety and Efficacy of Transcatheter Closure of Perimembranous Ventricular Septal Defects with a Single Device Type: A Single-Centre Experience

Wojciech Tarała, Oksana Trębacz, Robert Sabiniewicz, Jacek Podlewski, Piotr Weryński, Patrycja Florek
article en

Abstract

<b>Background/Objective</b>: Ventricular septal defect (VSD) is the most common congenital heart anomaly, with the perimembranous subtype (pmVSD) being among the most prevalent forms. Surgical repair remains the gold standard for treatment; however, percutaneous closure has emerged as a promising alternative due to the availability of various occlusion devices. Each technique presents distinct advantages and limitations, particularly in terms of complications and long-term outcomes. We sought to evaluate the safety and mid-term outcomes of pmVSD closure employing the Nit-Occlud<sup>®</sup> Le VSD Coil within a single-centre, single-team setting. <b>Methods</b>: Of the 55 patients hospitalised for pmVSD closure, 45 children underwent the procedure with the Nit-Occlud<sup>®</sup> Le VSD device. Relevant clinical and defect-related data were collected during hospitalisation and throughout follow-up. <b>Results</b>: Among 45 patients, successful coil implantation was achieved in 41 cases (91.1%). Periprocedural complications occurred in 8 patients (17.8%), including haemolysis, transient atrioventricular block, aortic valve injury, transient ST-segment elevation and supraventricular tachycardia. Two of these complications (4.4%) were classified as severe. The occurrence of complications was significantly associated with the type of VSD shunt (<i>p</i> = 0.03). <b>Conclusions</b>: Transcatheter closure of pmVSD using the Nit-Occlud<sup>®</sup> Lê VSD Coil in young children is a feasible and safe option with careful patient selection. Patients with type C pmVSD appear to benefit the most. Nevertheless, potential complications, including haemolysis and aortic valve injury, require close monitoring.

Journal of Clinical MedicineVol. 14(21)
University of Agriculture in Krakow (PL), Maj Institute of Pharmacology (PL), Gdańsk Medical University (PL), University of Rzeszów (PL)
Openalex Percentile: Top 57%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.