Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor

The ring-assisted Mach-Zehnder interferometer (RA-MZI) has high sensitivity and fast optical response time, and it has been used as a label-free nanophotonic biosensor. Most RA-MZI-based biosensors, however, require chemical modification of the ring surface to immobilize biomolecules that can interact with target molecules for sensing. Here, we report a novel microfluidic-integrated RA-MZI (μFRA-MZI) where a microfluidic channel was fabricated right above the photonic ring resonator. μFRA-MZI allows for direct sample delivery to the RA-MZI without chemical modification of the ring surface and measures shifts in the resonance wavelength induced by the presence of target molecules, enabling label-free detection. In order to optimize the sensitivity of μFRA-MZI, seven devices were fabricated with varied design parameters, including the gap distance between the ring and the bus waveguide (G<sub>ring</sub>), the length of the multi-mode interferometer (L<sub>MMI</sub>), and the length of the directional coupler (L<sub>DC</sub>). Photonic characterization showed that the device with G<sub>ring</sub> = 1.2 μm, L<sub>MMI</sub> = 15.5 μm, and L<sub>DC</sub> = 13.5 μm exhibited the highest extinction ratio (ER) compared to the other six devices, consistent with the simulation-optimized design. Testing with NaCl solutions of varying concentrations yielded a bulk sensitivity of 11.48 nm/refractive index unit (RIU) and an ER of 0.41. With the potential to further improve the device's sensitivity and the ability to detect samples directly in flow without chemical modifications of the ring resonator, μFRA-MZI will provide a robust and effective approach for label-free biosensing.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-11-04
DOI
https://doi.org/10.3390/bios15110741
Citations
1
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor

Zihao Wang, Jiandi Wan, Yunju Chang, Ethan Glenn Seutter
1 citations
Biosensors
Photonic and Optical Devices
0.73
article

Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor

Zihao Wang, Jiandi Wan, Yunju Chang, Ethan Glenn Seutter
article en
1 citations

Abstract

The ring-assisted Mach-Zehnder interferometer (RA-MZI) has high sensitivity and fast optical response time, and it has been used as a label-free nanophotonic biosensor. Most RA-MZI-based biosensors, however, require chemical modification of the ring surface to immobilize biomolecules that can interact with target molecules for sensing. Here, we report a novel microfluidic-integrated RA-MZI (μFRA-MZI) where a microfluidic channel was fabricated right above the photonic ring resonator. μFRA-MZI allows for direct sample delivery to the RA-MZI without chemical modification of the ring surface and measures shifts in the resonance wavelength induced by the presence of target molecules, enabling label-free detection. In order to optimize the sensitivity of μFRA-MZI, seven devices were fabricated with varied design parameters, including the gap distance between the ring and the bus waveguide (G<sub>ring</sub>), the length of the multi-mode interferometer (L<sub>MMI</sub>), and the length of the directional coupler (L<sub>DC</sub>). Photonic characterization showed that the device with G<sub>ring</sub> = 1.2 μm, L<sub>MMI</sub> = 15.5 μm, and L<sub>DC</sub> = 13.5 μm exhibited the highest extinction ratio (ER) compared to the other six devices, consistent with the simulation-optimized design. Testing with NaCl solutions of varying concentrations yielded a bulk sensitivity of 11.48 nm/refractive index unit (RIU) and an ER of 0.41. With the potential to further improve the device's sensitivity and the ability to detect samples directly in flow without chemical modifications of the ring resonator, μFRA-MZI will provide a robust and effective approach for label-free biosensing.

BiosensorsVol. 15(11)
Rochester Institute of Technology (US), University of California, Davis (US)
Gordon and Betty Moore Foundation
Openalex Percentile: Top 22%
Photonic and Optical Devices
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.