Development and performance analysis of glass-based gas-tight RPCs for muography applications

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood and widely used, our work focuses on developing a gas-tight variant specifically tailored for a broad range of muography applications, with key design goals including portability, robustness, autonomy, versatility, safety, and cost-effectiveness. Our RPC detectors are designed with various configurations, each featuring unique characteristics and performance attributes. We investigate the temporal evolution of the surface resistivity of glass electrodes, as well as the detector efficiency at varying voltages and thresholds, over a span of several months. These RPCs have been utilized in a small-scale feasibility study on muon absorption using lead blocks. This article is part of the Proceedings of the International Muography Workshop 2024 held in Santa Fe, New Mexico, USA.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2025-11-04
DOI
https://doi.org/10.1063/5.0275200
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and performance analysis of glass-based gas-tight RPCs for muography applications

S. Basnet, R. M. I. D. Gamage, A. Samalan, Vishal Kumar et al.
Journal of Applied Physics
Particle Detector Development and Performance
article

Development and performance analysis of glass-based gas-tight RPCs for muography applications

S. Basnet, R. M. I. D. Gamage, A. Samalan, Vishal Kumar, Marwa Al Moussawi, R. Karnam, E. Cortina, B. Mohanty, ANDREA GIAMMANCO, Sumaira Ikram, Vipul Kashyap, P. Demin, M. Tytgat
article en

Abstract

To achieve high-resolution muography of compact targets in scenarios with complex logistical constraints, we are developing a portable muon detector system utilizing glass Resistive Plate Chambers (RPCs). Although RPCs are well understood and widely used, our work focuses on developing a gas-tight variant specifically tailored for a broad range of muography applications, with key design goals including portability, robustness, autonomy, versatility, safety, and cost-effectiveness. Our RPC detectors are designed with various configurations, each featuring unique characteristics and performance attributes. We investigate the temporal evolution of the surface resistivity of glass electrodes, as well as the detector efficiency at varying voltages and thresholds, over a span of several months. These RPCs have been utilized in a small-scale feasibility study on muon absorption using lead blocks. This article is part of the Proceedings of the International Muography Workshop 2024 held in Santa Fe, New Mexico, USA.

Journal of Applied PhysicsVol. 138(17)
HOGENT University of Applied Sciences and Arts (BE), Vrije Universiteit Brussel (BE), National Institute of Science Education and Research (IN), Ghent University Hospital (BE), Ghent University (BE), Interuniversity Institute for High Energies (BE), UCLouvain (BE)
Openalex Percentile: Top 85%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.