QUANTITATIVE ASSESSMENT OF HEAVY METAL CONTENT IN “HIBISCUS MICRANTHUS LINN”

The heavy metal analysis of Hibiscus Micranthus was conducted using the Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) instrument, employing a precise and robust methodology. Approximately 20 mg of the plant sample was subjected to microwave-assisted digestion using ultrapure nitric acid, ensuring complete breakdown of the matrix over a 45-minute digestion period. The digested sample was then diluted to a final volume of 50 mL for analysis. To guarantee accurate quantification, calibration standards of arsenic, cadmium, mercury, and lead were prepared at concentrations ranging from 2 µg/mL to 10 µg/mL, which established high linearity for each respective metal, with correlation coefficients exceeding 0.996. The ICP-OES instrument was optimized with an RF power setting of 1.2 kW, a plasma gas flow rate of 12 L/min, and a nebulizer gas flow rate of 0.70 L/min to enhance the sensitivity and reproducibility of detection. Analytical results indicated that the levels of all tested heavy metals arsenic, cadmium, mercury, and lead—were below the detection limits of the instrument, signifying negligible or non-detectable contamination in the Hibiscus Micranthus sample. This outcome confirms the sample's safety for pharmaceutical or herbal applications, minimizing concerns related to heavy metal toxicity. The study further validated the analytical procedure by documenting calibration curves and linearity graphs, reinforcing the reliability of the method used. Overall, this ICPOES-based evaluation establishes a trustworthy framework for heavy metal determination in herbal materials, contributing critical insights into the quality control of Hibiscus Micranthus and endorsing its continued use where safety is paramount. The results are significant for researchers and manufacturers focused on ensuring contaminant-free botanical products through advanced instrumental techniques.

Authors

Institutions

Publication Details

Journal
PARIPEX INDIAN JOURNAL OF RESEARCH
Published
2025-10-15
DOI
https://doi.org/10.36106/paripex/0804830
Primary Topic
Hibiscus Plant Research Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QUANTITATIVE ASSESSMENT OF HEAVY METAL CONTENT IN “HIBISCUS MICRANTHUS LINN”

S. Mahalakshmi, M. Loganayagi, Vinod Kumar Maheswari, V. R. Ravikkumar et al.
PARIPEX INDIAN JOURNAL OF RESEARCH
Hibiscus Plant Research Studies
article

QUANTITATIVE ASSESSMENT OF HEAVY METAL CONTENT IN “HIBISCUS MICRANTHUS LINN”

S. Mahalakshmi, M. Loganayagi, Vinod Kumar Maheswari, V. R. Ravikkumar, K. P. Boovizhi, R. Sathiya, c Srikeerthivasan.
article en

Abstract

The heavy metal analysis of Hibiscus Micranthus was conducted using the Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) instrument, employing a precise and robust methodology. Approximately 20 mg of the plant sample was subjected to microwave-assisted digestion using ultrapure nitric acid, ensuring complete breakdown of the matrix over a 45-minute digestion period. The digested sample was then diluted to a final volume of 50 mL for analysis. To guarantee accurate quantification, calibration standards of arsenic, cadmium, mercury, and lead were prepared at concentrations ranging from 2 µg/mL to 10 µg/mL, which established high linearity for each respective metal, with correlation coefficients exceeding 0.996. The ICP-OES instrument was optimized with an RF power setting of 1.2 kW, a plasma gas flow rate of 12 L/min, and a nebulizer gas flow rate of 0.70 L/min to enhance the sensitivity and reproducibility of detection. Analytical results indicated that the levels of all tested heavy metals arsenic, cadmium, mercury, and lead—were below the detection limits of the instrument, signifying negligible or non-detectable contamination in the Hibiscus Micranthus sample. This outcome confirms the sample's safety for pharmaceutical or herbal applications, minimizing concerns related to heavy metal toxicity. The study further validated the analytical procedure by documenting calibration curves and linearity graphs, reinforcing the reliability of the method used. Overall, this ICPOES-based evaluation establishes a trustworthy framework for heavy metal determination in herbal materials, contributing critical insights into the quality control of Hibiscus Micranthus and endorsing its continued use where safety is paramount. The results are significant for researchers and manufacturers focused on ensuring contaminant-free botanical products through advanced instrumental techniques.

PARIPEX INDIAN JOURNAL OF RESEARCH
Rhodes College (US), Strode College (GB)
Openalex Percentile: Top 58%
Hibiscus Plant Research Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.