Novel PEEK fabrication using fused strand deposition reduces inflammation and enhances MSC differentiation promoting bone growth and implant osseointegration

Spine fusion devices fabricated from polyether ether ketone (PEEK) using traditional machining or with surface pores created by salt leaching result in a fibrous connective tissue interface. To overcome this limitation, we used fused strand deposition (FSD), which elevates fused filament fabrication (FFF) or fused deposition modeling (FDM) to generate a first-of-its-kind PEEK implant with an architecture designed to mimic trabecular bone. We examined the responses of human bone marrow stromal cells (MSCs) and macrophages isolated from the femurs of C57/Bl6 male mice to the additively manufactured porous PEEK (PP) and porous PEEK coated with HA (PP-HA) to determine if these modifications would improve cell response compared to solid PEEK (SP). PP and PP-HA constructs had similar 3D architectures but differed in hydrophilicity (PP-HA > PP). MSCs and macrophages were cultured on PP, PP-HA, and SP, and osteoblast differentiation and M1/M2 polarization were assessed. MSCs attached to the SP surface and the PP and PP-HA fibers, and synthesized osteoblast proteins in a surface-dependent manner. Notably, MSCs and macrophages produced VEGF mRNA and protein on PP-HA at levels higher than those on PP or SP. Macrophages grown on PP and PP-HA exhibited reduced expression of pro-inflammatory cytokines compared to cells on SP and increased levels of anti-inflammatory cytokines, but they did not exhibit a distinct M1 or M2 phenotype. These results show that additive manufacturing of a unique, fully porous PEEK implant using FSD, results in a surface that promotes MSC differentiation and decreases the pro-inflammatory response of macrophages to the surface, suggesting that PP and PP-HA implants will improve regeneration and eventually osseointegration in vivo. Importantly, the mechanisms involved are not the same as would be expected when testing Ti6Al4V substrates under the same experimental conditions and may have been obscured if the cells had been cultured using osteogenic media (OM). We correlated our in vitro findings with the clinical use of PP-HA implants in four patients, each of whom was treated with a different bone graft material; in all cases, fusion was achieved.

Authors

Institutions

Publication Details

Journal
Biomaterials
Published
2025-11-04
DOI
https://doi.org/10.1016/j.biomaterials.2025.123833
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel PEEK fabrication using fused strand deposition reduces inflammation and enhances MSC differentiation promoting bone growth and implant osseointegration

Erik M. Erbe, Dmitry Pestov, Eleanor L. Sabalewski, Barbara D. Boyan et al.
1 citations
Biomaterials
Bone Tissue Engineering Materials
0.67
article

Novel PEEK fabrication using fused strand deposition reduces inflammation and enhances MSC differentiation promoting bone growth and implant osseointegration

Erik M. Erbe, Dmitry Pestov, Eleanor L. Sabalewski, Barbara D. Boyan, Kevin T. Foley, Massimo F. Bertino, Randall F. Dryer, Zvi Schwartz, T. M. Reith, Abdullah M. Jawad, Brian C. Verrelli, David J. Cohen, Paul Slosar, J. S. Deng, Jonathan T. Dillon, Timothy D Bassett, Curtis S. Harrod
article en
1 citations

Abstract

Spine fusion devices fabricated from polyether ether ketone (PEEK) using traditional machining or with surface pores created by salt leaching result in a fibrous connective tissue interface. To overcome this limitation, we used fused strand deposition (FSD), which elevates fused filament fabrication (FFF) or fused deposition modeling (FDM) to generate a first-of-its-kind PEEK implant with an architecture designed to mimic trabecular bone. We examined the responses of human bone marrow stromal cells (MSCs) and macrophages isolated from the femurs of C57/Bl6 male mice to the additively manufactured porous PEEK (PP) and porous PEEK coated with HA (PP-HA) to determine if these modifications would improve cell response compared to solid PEEK (SP). PP and PP-HA constructs had similar 3D architectures but differed in hydrophilicity (PP-HA > PP). MSCs and macrophages were cultured on PP, PP-HA, and SP, and osteoblast differentiation and M1/M2 polarization were assessed. MSCs attached to the SP surface and the PP and PP-HA fibers, and synthesized osteoblast proteins in a surface-dependent manner. Notably, MSCs and macrophages produced VEGF mRNA and protein on PP-HA at levels higher than those on PP or SP. Macrophages grown on PP and PP-HA exhibited reduced expression of pro-inflammatory cytokines compared to cells on SP and increased levels of anti-inflammatory cytokines, but they did not exhibit a distinct M1 or M2 phenotype. These results show that additive manufacturing of a unique, fully porous PEEK implant using FSD, results in a surface that promotes MSC differentiation and decreases the pro-inflammatory response of macrophages to the surface, suggesting that PP and PP-HA implants will improve regeneration and eventually osseointegration in vivo. Importantly, the mechanisms involved are not the same as would be expected when testing Ti6Al4V substrates under the same experimental conditions and may have been obscured if the cells had been cultured using osteogenic media (OM). We correlated our in vitro findings with the clinical use of PP-HA implants in four patients, each of whom was treated with a different bone graft material; in all cases, fusion was achieved.

BiomaterialsVol. 328
Louisiana Department of Education (US), Virginia Commonwealth University (US), Semmes Murphey Foundation (US), AZ Technology (United States) (US), Dermatology Specialists (US), Central Texas Spine Institute (US), MD Informatics (United States) (US)
Openalex Percentile: Top 25%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.