<b>A New Green CFIA/MZT System for Spectrophotometric Determination of Anthranilic Acid</b>

Anthranilic acid (AA) was determined in pure material via a new system of the CFIA method that involves less chemical consumption (μL), is rapid, semiautomated, simple, and accurate. Two reactions of the AA were conducted; the first, with 4-amino antipyrine and potassium periodate as the oxidizing agent, yielded a pinkish-violet colored product, which was measured at λmax 550 nm. The second reaction, using 2,2`-bipyridine with FeCl3, produced a Pinkish-red product, which was measured at λmax 521 nm. Other chemical and physical factors that affect the stability of the complex products in the suggested process include flow rate, reagent concentration, sample volume, dispersion, and reaction coil. The linearity ranges were (10-400) and (5-150) µg.mL-1, the average recovery percentages were 100.995 and 100.974, while the error percentages were 0.995 and 0.974, respectively. The detection limit values were 1.63 and 0.69 μg.mL-1, respectively. A relative standard deviation of 0.28% and 0.65% was observed, and the sample throughput was 80 and 90 samples/hour, respectively. The devised approach was tested against the conventional method and was shown to be more sensitive. Moreover, a t-test was used to contrast "true value" with "practical value". At the 95% confidence level, it was found that the values were not significantly different.

Authors

Institutions

Publication Details

Journal
Ibn AL- Haitham Journal For Pure and Applied Science
Published
2025-10-20
DOI
https://doi.org/10.30526/38.4.4155
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Green CFIA/MZT System for Spectrophotometric Determination of Anthranilic Acid

Jehan Sh. Hussien, Bushra B. Qassim
Ibn AL- Haitham Journal For Pure and Applied Science
Analytical Methods in Pharmaceuticals
article

A New Green CFIA/MZT System for Spectrophotometric Determination of Anthranilic Acid

Jehan Sh. Hussien, Bushra B. Qassim
article en

Abstract

Anthranilic acid (AA) was determined in pure material via a new system of the CFIA method that involves less chemical consumption (μL), is rapid, semiautomated, simple, and accurate. Two reactions of the AA were conducted; the first, with 4-amino antipyrine and potassium periodate as the oxidizing agent, yielded a pinkish-violet colored product, which was measured at λmax 550 nm. The second reaction, using 2,2`-bipyridine with FeCl3, produced a Pinkish-red product, which was measured at λmax 521 nm. Other chemical and physical factors that affect the stability of the complex products in the suggested process include flow rate, reagent concentration, sample volume, dispersion, and reaction coil. The linearity ranges were (10-400) and (5-150) µg.mL-1, the average recovery percentages were 100.995 and 100.974, while the error percentages were 0.995 and 0.974, respectively. The detection limit values were 1.63 and 0.69 μg.mL-1, respectively. A relative standard deviation of 0.28% and 0.65% was observed, and the sample throughput was 80 and 90 samples/hour, respectively. The devised approach was tested against the conventional method and was shown to be more sensitive. Moreover, a t-test was used to contrast "true value" with "practical value". At the 95% confidence level, it was found that the values were not significantly different.

Ibn AL- Haitham Journal For Pure and Applied ScienceVol. 38(4)
University of Baghdad (IQ)
University of Baghdad
Openalex Percentile: Top 63%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

<b>A New Green CFIA/MZT System for Spectrophotometric Determination of Anthranilic Acid</b> — Jehan Sh. Hussien, Bushra B. Qassim · Ibn AL- Haitham Journal For Pure and Applied Science (2025) | TGRS Research Map | TGRS