Portable mixed reality navigation system for neurosurgery: a clinical feasibility study

This study aimed to develop a portable mixed reality navigation (PMRN) system for neurosurgery and assess its feasibility, providing design insights for the optimization and wider adoption of mixed reality navigation. The PMRN system linked a head-mounted display (HMD) and a portable laptop via a router, forming a local network. Active infrared tracking enabled real-time localization of a custom surgical probe. Accuracy was first tested in a laboratory using simulation models, then evaluated in a prospective clinical study of 42 patients with intracranial lesions. Clinically, the probe of a traditional optical navigation (TON) system was placed at PMRN-localized targets, and the Euclidean distance between the two systems was measured to quantify localization error. Doctors also subjectively assessed the alignment of mixed reality holograms with patient anatomy to evaluate reliability. In laboratory testing, two doctors each performed 10 simulated head model localizations, with an average time of under 5 min. The times decreased with practice and stabilized at approximately 3.5 min. The maximum fiducial registration error (FRE) and target registration error (TRE) were 2.5 mm and 2.3 mm, respectively, with no significant difference between doctors. In the clinical study (n = 42 patients), the mean localization time was 4.3 ± 1.0 min, the FRE was 2.2 ± 0.7 mm, and the TRE was 1.7 ± 0.5 mm. Doctors rated the hologram-patient alignment as satisfactory in 40 cases (95%); the remaining two cases showed a 3 mm deviation, which was attributed to slight patient movement or reduced device performance in low-battery mode. The PMRN system is portable, easy to use, and achieves millimeter-level accuracy in neurosurgical procedures with high surgeon satisfaction. It meets the needs of most routine operations but requires further refinement for submillimeter-precision procedures. These results confirm its clinical feasibility and support its further development and adoption in mixed reality neurosurgical navigation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-04
DOI
https://doi.org/10.1038/s41598-025-24603-6
Citations
1
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
1.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable mixed reality navigation system for neurosurgery: a clinical feasibility study

Xin Gao, Xiaojun Li, Gang Chen, Zhanxiang Wang et al.
1 citations
Scientific Reports
Augmented Reality Applications
1.28
article

Portable mixed reality navigation system for neurosurgery: a clinical feasibility study

Xin Gao, Xiaojun Li, Gang Chen, Zhanxiang Wang, Zhongjie Shi, Shujie Sun, Yilong Peng
article en
1 citations

Abstract

This study aimed to develop a portable mixed reality navigation (PMRN) system for neurosurgery and assess its feasibility, providing design insights for the optimization and wider adoption of mixed reality navigation. The PMRN system linked a head-mounted display (HMD) and a portable laptop via a router, forming a local network. Active infrared tracking enabled real-time localization of a custom surgical probe. Accuracy was first tested in a laboratory using simulation models, then evaluated in a prospective clinical study of 42 patients with intracranial lesions. Clinically, the probe of a traditional optical navigation (TON) system was placed at PMRN-localized targets, and the Euclidean distance between the two systems was measured to quantify localization error. Doctors also subjectively assessed the alignment of mixed reality holograms with patient anatomy to evaluate reliability. In laboratory testing, two doctors each performed 10 simulated head model localizations, with an average time of under 5 min. The times decreased with practice and stabilized at approximately 3.5 min. The maximum fiducial registration error (FRE) and target registration error (TRE) were 2.5 mm and 2.3 mm, respectively, with no significant difference between doctors. In the clinical study (n = 42 patients), the mean localization time was 4.3 ± 1.0 min, the FRE was 2.2 ± 0.7 mm, and the TRE was 1.7 ± 0.5 mm. Doctors rated the hologram-patient alignment as satisfactory in 40 cases (95%); the remaining two cases showed a 3 mm deviation, which was attributed to slight patient movement or reduced device performance in low-battery mode. The PMRN system is portable, easy to use, and achieves millimeter-level accuracy in neurosurgical procedures with high surgeon satisfaction. It meets the needs of most routine operations but requires further refinement for submillimeter-precision procedures. These results confirm its clinical feasibility and support its further development and adoption in mixed reality neurosurgical navigation.

Scientific ReportsVol. 15(1)
Xiamen University (CN), First Affiliated Hospital of Xiamen University (CN), Shanghai International Medical Center (CN), Zhuhai People's Hospital (CN), Shanghai Xuhui Central Hospital (CN), Jiangmen Central Hospital (CN)
Openalex Percentile: Top 15%
Augmented Reality Applications
1.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.