Collaborative optimization of dynamic early warning and control in desulphurization process via integration of causal inference and temporal features

Abstract The inherent time‐lag effects, nonlinear dependencies, and dynamic coupling mechanisms in desulphurization processes pose significant challenges to precise quality prediction and proactive control. This study presents a novel collaborative optimization framework integrating causal inference with temporal feature engineering to achieve dynamic early warning and intelligent control. Methodologically, we first develop a multi‐modal time‐lag estimation approach combining dynamic time warping, Granger causality tests, and time‐delayed mutual information, resolving temporal asynchrony between process variables through dynamic programming and information‐theoretic analysis. Building upon this, a dynamic autoregressive latent variable model (DALM) with Bayesian estimation is established to capture cross‐variable interaction dynamics, enhanced by a long short‐term memory (LSTM)‐based architecture with attention mechanisms for nonlinear temporal dependency modelling. The proposed early‐warning system synergizes anomaly detection (isolation forest/one‐class SVM/autoencoder triad) with NOTEARS‐optimized causal graphs, achieving 93.1% prediction accuracy (AUC = 0.98) through multi‐feature fusion of temporal patterns, causal drivers, and multivariate anomalies. For control optimization, formulate a hybrid MPC strategy incorporating warning‐adaptive penalty terms, demonstrating 89.2% warning probability alignment with quality deviations while the concentrations of SO 2 /H 2 S are kept within a fixed range through restricted reactor feed flow adjustment. Validations confirm the framework reduces unplanned shutdowns by 37% compared to conventional PID control, with R 2 = 0.9144 for SO 2 and 0.9114 for H 2 S concentration predictions. This work provides a systematic solution addressing temporal‐causal decoupling challenges in complex chemical processes, significantly advancing intelligent optimization in pollution control systems.

Authors

Institutions

Publication Details

Journal
The Canadian Journal of Chemical Engineering
Published
2025-11-03
DOI
https://doi.org/10.1002/cjce.70140
Citations
1
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Collaborative optimization of dynamic early warning and control in desulphurization process via integration of causal inference and temporal features

Bozhi Yang, He Li, Xiaofei Gu
1 citations
The Canadian Journal of Chemical Engineering
Fault Detection and Control Systems
1.21
article

Collaborative optimization of dynamic early warning and control in desulphurization process via integration of causal inference and temporal features

Bozhi Yang, He Li, Xiaofei Gu
article en
1 citations

Abstract

Abstract The inherent time‐lag effects, nonlinear dependencies, and dynamic coupling mechanisms in desulphurization processes pose significant challenges to precise quality prediction and proactive control. This study presents a novel collaborative optimization framework integrating causal inference with temporal feature engineering to achieve dynamic early warning and intelligent control. Methodologically, we first develop a multi‐modal time‐lag estimation approach combining dynamic time warping, Granger causality tests, and time‐delayed mutual information, resolving temporal asynchrony between process variables through dynamic programming and information‐theoretic analysis. Building upon this, a dynamic autoregressive latent variable model (DALM) with Bayesian estimation is established to capture cross‐variable interaction dynamics, enhanced by a long short‐term memory (LSTM)‐based architecture with attention mechanisms for nonlinear temporal dependency modelling. The proposed early‐warning system synergizes anomaly detection (isolation forest/one‐class SVM/autoencoder triad) with NOTEARS‐optimized causal graphs, achieving 93.1% prediction accuracy (AUC = 0.98) through multi‐feature fusion of temporal patterns, causal drivers, and multivariate anomalies. For control optimization, formulate a hybrid MPC strategy incorporating warning‐adaptive penalty terms, demonstrating 89.2% warning probability alignment with quality deviations while the concentrations of SO 2 /H 2 S are kept within a fixed range through restricted reactor feed flow adjustment. Validations confirm the framework reduces unplanned shutdowns by 37% compared to conventional PID control, with R 2 = 0.9144 for SO 2 and 0.9114 for H 2 S concentration predictions. This work provides a systematic solution addressing temporal‐causal decoupling challenges in complex chemical processes, significantly advancing intelligent optimization in pollution control systems.

The Canadian Journal of Chemical Engineering
Changzhou Institute of Technology (CN), Anyang Normal University (CN)
Openalex Percentile: Top 15%
Fault Detection and Control Systems
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.