Impact Of Four Registration Strategies On Virtual Occlusal Records’ Accuracy

To compare four registration strategies' impact on virtual occlusal records (VOR) accuracy in mandibular free-end edentulism with multiple missing teeth. A typodont model with missing teeth (46, 48, 35-38) was mounted on a semi-adjustable articulator in maximal intercuspal position (MIP). Twelve steel balls (diameter=0.5 mm) were attached at reference positions (16-46, 13-43, 23-33, 25-35, 26-36, and 27-37). Reference datasets were scanned using a laboratory scanner (inEox X5). Four registration strategies were applied using the intraoral scanner (Medit i700): left-side registration (GroupL), right-side registration (GroupR), bilateral registration (GroupB), and anterior-side registration (GroupA). Randomization was performed to minimize bias in strategy sequence. Each strategy was repeated 10 times, generating four VOR datasets. Geomagic Control software measured linear distances and calculated deviations from reference scan. Non-normal data distribution was confirmed, and Kruskal-Wallis tests analyzed accuracy and precision (α = 0.05). Both the scanning strategy and the linear distance positions significantly impacted the VOR accuracy. In mandibular distal extension areas (D2535, D2636, D2737), GroupL and GroupB demonstrated similar performance (P > 0.05), whereas both significantly outperformed GroupR (P < 0.05); conversely, in regions D1343 and D1646, GroupB and GroupR showed superior accuracy over GroupL (P < 0.05) . GroupB achieved the highest trueness (deviations ≤150 μm) across all positions. VOR accuracy decreased significantly in mandibular free-end partial edentulism, risking occlusal vertical dimension underestimation. With Medit i700, bilateral registration achieves the highest VOR accuracy, and warrants clinical application.

Authors

Institutions

Publication Details

Journal
International Dental Journal
Published
2025-10-01
DOI
https://doi.org/10.1016/j.identj.2025.105669
Primary Topic
Temporomandibular Joint Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact Of Four Registration Strategies On Virtual Occlusal Records’ Accuracy

Jiehua Tian, Yuanliang Huang, Yuqi Han, Yupeng Mei
International Dental Journal
Temporomandibular Joint Disorders
article

Impact Of Four Registration Strategies On Virtual Occlusal Records’ Accuracy

Jiehua Tian, Yuanliang Huang, Yuqi Han, Yupeng Mei
article en

Abstract

To compare four registration strategies' impact on virtual occlusal records (VOR) accuracy in mandibular free-end edentulism with multiple missing teeth. A typodont model with missing teeth (46, 48, 35-38) was mounted on a semi-adjustable articulator in maximal intercuspal position (MIP). Twelve steel balls (diameter=0.5 mm) were attached at reference positions (16-46, 13-43, 23-33, 25-35, 26-36, and 27-37). Reference datasets were scanned using a laboratory scanner (inEox X5). Four registration strategies were applied using the intraoral scanner (Medit i700): left-side registration (GroupL), right-side registration (GroupR), bilateral registration (GroupB), and anterior-side registration (GroupA). Randomization was performed to minimize bias in strategy sequence. Each strategy was repeated 10 times, generating four VOR datasets. Geomagic Control software measured linear distances and calculated deviations from reference scan. Non-normal data distribution was confirmed, and Kruskal-Wallis tests analyzed accuracy and precision (α = 0.05). Both the scanning strategy and the linear distance positions significantly impacted the VOR accuracy. In mandibular distal extension areas (D2535, D2636, D2737), GroupL and GroupB demonstrated similar performance (P > 0.05), whereas both significantly outperformed GroupR (P < 0.05); conversely, in regions D1343 and D1646, GroupB and GroupR showed superior accuracy over GroupL (P < 0.05) . GroupB achieved the highest trueness (deviations ≤150 μm) across all positions. VOR accuracy decreased significantly in mandibular free-end partial edentulism, risking occlusal vertical dimension underestimation. With Medit i700, bilateral registration achieves the highest VOR accuracy, and warrants clinical application.

International Dental JournalVol. 75
Peking University (CN)
Openalex Percentile: Top 61%
Temporomandibular Joint Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact Of Four Registration Strategies On Virtual Occlusal Records’ Accuracy — Jiehua Tian, Yuanliang Huang, et al. · International Dental Journal (2025) | TGRS Research Map | TGRS