Assessment of thyroid counter accuracy using Caesium −137 and Europium −152 and personnel effective dose

Occupational exposure to unsealed radionuclides in nuclear medicine and industrial environments underscores the critical need for precise internal dose assessments to ensure radiation protection and regulatory compliance. The thyroid is particularly susceptible during radioiodine (I-131) treatment, underscoring the need for reliable monitoring systems. This study evaluates the reliability of the WBC-T ORTEC thyroid counter, a crucial system for occupational dosimetry. This system comprises of 2" × 2″ NaI(Tl) detector with lead-lined copper shielding, which makes it stable and sensitive. The study's originality is its robust and systematic method for validating results. This method combines background analysis, quality control testing, chi-square reliability checks, and an in-depth investigation at the Minimum Detectable Activity (MDA). This study examined a variety of geometries, acquisition times, and energies. It used Cs-137 (662 keV) and Eu-152 (121–1408 keV) as reference sources for energy calibration. The source is mounted inside a neck phantom. Background measurements, conducted in both open and closed laboratory settings, consistently produced coefficients of variation below 5 %, thereby validating the system's reproducibility. Quality control trials utilising Cs-137 over several sessions demonstrated percentage deviations within the ±5 % tolerance stipulated by international standards. Using longer acquisition times, up to 1800 s, helped reduce background variability and improve measurement accuracy. The results of the chi-square test showed stable values (4.47–4.58), which fell within the manufacturer's approved range (4.1–14.7). This confirmed statistical reliability and compliance with Poisson expectations. MDA findings demonstrated a strong relationship with counting duration and the distance between the detector and phantom, with optimal sensitivity recorded at closer geometries and extended acquisition periods. At the energy peaks of this study, the observed MDAs are attributed to improved intrinsic detection efficiency, while increased photon energy and distance diminish sensitivity. Assessments of linearity and consistency further confirmed robust long-term stability. The assessments confirmed that the WBC-T ORTEC thyroid counter demonstrates notable reliability, stability and sensitivity under optimised measurement conditions. Notably, the validated performance directly supports its application in occupational settings for detecting thyroidal I-131 uptake in nuclear medicine personnel. By enabling accurate activity quantification and subsequent committed practical dose estimation, the system ensures compliance with regulatory dose limits, thereby reinforcing its suitability for routine monitoring of personnel.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2025-11-03
DOI
https://doi.org/10.1016/j.jrras.2025.102051
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of thyroid counter accuracy using Caesium −137 and Europium −152 and personnel effective dose

Zuhal Y. Hamd, R.S. Omar, Norsyahidah Mohd Hidzir, Mayeen Uddin Khandaker et al.
Journal of Radiation Research and Applied Sciences
Radiation Dose and Imaging
article

Assessment of thyroid counter accuracy using Caesium −137 and Europium −152 and personnel effective dose

Zuhal Y. Hamd, R.S. Omar, Norsyahidah Mohd Hidzir, Mayeen Uddin Khandaker, Nazreen Ismail, Nora Almuqbil, Musalmah Mazlan, Anees Ahmad
article en

Abstract

Occupational exposure to unsealed radionuclides in nuclear medicine and industrial environments underscores the critical need for precise internal dose assessments to ensure radiation protection and regulatory compliance. The thyroid is particularly susceptible during radioiodine (I-131) treatment, underscoring the need for reliable monitoring systems. This study evaluates the reliability of the WBC-T ORTEC thyroid counter, a crucial system for occupational dosimetry. This system comprises of 2" × 2″ NaI(Tl) detector with lead-lined copper shielding, which makes it stable and sensitive. The study's originality is its robust and systematic method for validating results. This method combines background analysis, quality control testing, chi-square reliability checks, and an in-depth investigation at the Minimum Detectable Activity (MDA). This study examined a variety of geometries, acquisition times, and energies. It used Cs-137 (662 keV) and Eu-152 (121–1408 keV) as reference sources for energy calibration. The source is mounted inside a neck phantom. Background measurements, conducted in both open and closed laboratory settings, consistently produced coefficients of variation below 5 %, thereby validating the system's reproducibility. Quality control trials utilising Cs-137 over several sessions demonstrated percentage deviations within the ±5 % tolerance stipulated by international standards. Using longer acquisition times, up to 1800 s, helped reduce background variability and improve measurement accuracy. The results of the chi-square test showed stable values (4.47–4.58), which fell within the manufacturer's approved range (4.1–14.7). This confirmed statistical reliability and compliance with Poisson expectations. MDA findings demonstrated a strong relationship with counting duration and the distance between the detector and phantom, with optimal sensitivity recorded at closer geometries and extended acquisition periods. At the energy peaks of this study, the observed MDAs are attributed to improved intrinsic detection efficiency, while increased photon energy and distance diminish sensitivity. Assessments of linearity and consistency further confirmed robust long-term stability. The assessments confirmed that the WBC-T ORTEC thyroid counter demonstrates notable reliability, stability and sensitivity under optimised measurement conditions. Notably, the validated performance directly supports its application in occupational settings for detecting thyroidal I-131 uptake in nuclear medicine personnel. By enabling accurate activity quantification and subsequent committed practical dose estimation, the system ensures compliance with regulatory dose limits, thereby reinforcing its suitability for routine monitoring of personnel.

Journal of Radiation Research and Applied SciencesVol. 18(4)
Princess Nourah bint Abdulrahman University (SA), Korea University (KR), Daffodil International University (BD), Malaysian Nuclear Agency (MY), Sunway University (MY), National University of Malaysia (MY)
Openalex Percentile: Top 53%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.