Effective Visualization of the Intracranially Implanted Neurosurgical Devices with Photon-counting Detector Computed Tomography:A Technical Note

Photon-counting detector computed tomography (PCD-CT) allows for attainment of images with excellent spatial resolution at reduced radiation doses. However, practical utility of this diagnostic modality in neurosurgery is still not defined well. Herein, the authors report their initial experience with the use of postoperative PCD-CT (helical pitch, 0.85;gantry rotation time, 0.5 s;tube voltage, 120 kV) in a single-acquisition high-resolution mode with the iterative metal artifact reduction and attainment of the reconstructed images with slice thickness of 0.2 mm for assessment of the shunt valve pressure adjustment system and endovascular flow-diverting stent. In both cases, intracranially implanted neurosurgical devices were effectively visualized. J. Med. Invest. 72 : 463-466, August, 2025.

Authors

Institutions

Publication Details

Journal
The Journal of Medical Investigation
Published
2025-01-01
DOI
https://doi.org/10.2152/jmi.72.463
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effective Visualization of the Intracranially Implanted Neurosurgical Devices with Photon-counting Detector Computed Tomography:A Technical Note

Tatsuya Hoshino, Tadasuke Tominaga, Hanako Morisawa, Takakazu Kawamata et al.
The Journal of Medical Investigation
Advanced X-ray and CT Imaging
article

Effective Visualization of the Intracranially Implanted Neurosurgical Devices with Photon-counting Detector Computed Tomography:A Technical Note

Tatsuya Hoshino, Tadasuke Tominaga, Hanako Morisawa, Takakazu Kawamata, Naohisa Miura, Takahiro Yokoyama, Suguru Nakamura
article en

Abstract

Photon-counting detector computed tomography (PCD-CT) allows for attainment of images with excellent spatial resolution at reduced radiation doses. However, practical utility of this diagnostic modality in neurosurgery is still not defined well. Herein, the authors report their initial experience with the use of postoperative PCD-CT (helical pitch, 0.85;gantry rotation time, 0.5 s;tube voltage, 120 kV) in a single-acquisition high-resolution mode with the iterative metal artifact reduction and attainment of the reconstructed images with slice thickness of 0.2 mm for assessment of the shunt valve pressure adjustment system and endovascular flow-diverting stent. In both cases, intracranially implanted neurosurgical devices were effectively visualized. J. Med. Invest. 72 : 463-466, August, 2025.

The Journal of Medical InvestigationVol. 72(3.4)
Tokyo Women's Medical University Adachi Medical Center (JP), Mie Chuo Medical Center (JP), Tokyo Women's Medical University (JP)
Tokyo Women's Medical University
Openalex Percentile: Top 68%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.