Dosimetric Impact of Air Gaps in High-Dose-Rate Contact Interventional Radiotherapy (Modern Brachytherapy) for Non-Melanoma Skin Cancer of the Ear

<b>Background/Objectives:</b> The anatomical complexity of the auricular region poses a unique challenge for contact interventional radiotherapy (IRT, modern brachytherapy), especially in maintaining close conformity between the applicator and skin surface. Air gaps can arise due to the irregular shape of the ear, potentially compromising dose coverage. This study evaluates the dosimetric impact of air gaps in HDR IRT for non-melanoma skin cancer (NMSC) of the ear. <b>Methods:</b> Ten patients treated with contact IRT using alginate as supporting material were retrospectively analyzed. Treatment plans were recalculated using both the TG-43 and the TG-186 formalism. CTV coverage and organ-at-risk dose parameters were evaluated within the two formalisms. <b>Results:</b> CTV coverage was comparable between algorithms (mean V95% 96.2% vs. 94.4%, V100% 89.6% vs. 86.7%, and V150% 2.6% vs. 2.5% for TG-43 vs. TG-186; <i>p</i> > 0.05), while the ipsilateral eye D2cc decreased from 4.0% (TG-43) to 3.2% (TG-186). In silico simulations showed that increasing air gaps reduced skin dose progressively (up to ~15% at 5 mm), whereas alginate thickness produced only a mild dose increase (<5%) across the tested range. Overall, small air pockets (<1 mm) did not substantially alter global dosimetric metrics, although local underdosage may occur at gap locations. <b>Conclusions:</b> This study underscores the importance of accounting for material heterogeneities and geometric uncertainties in anatomically complex regions through advanced dose calculation algorithms.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-11-03
DOI
https://doi.org/10.3390/jcm14217790
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Impact of Air Gaps in High-Dose-Rate Contact Interventional Radiotherapy (Modern Brachytherapy) for Non-Melanoma Skin Cancer of the Ear

Bruno Fionda, Valentina Lancellotta, Maria Vaccaro, Francesca Greco et al.
Journal of Clinical Medicine
Advanced Radiotherapy Techniques
article

Dosimetric Impact of Air Gaps in High-Dose-Rate Contact Interventional Radiotherapy (Modern Brachytherapy) for Non-Melanoma Skin Cancer of the Ear

Bruno Fionda, Valentina Lancellotta, Maria Vaccaro, Francesca Greco, Gabriele Ciasca, Francesco Pastore, Marco De Spirito, Elisa Placidi, Antonio Napolitano, Maria Concetta La Milia, Luca Tagliaferri, Enrico Rosa, Pierpaolo Dragonetti
article en

Abstract

<b>Background/Objectives:</b> The anatomical complexity of the auricular region poses a unique challenge for contact interventional radiotherapy (IRT, modern brachytherapy), especially in maintaining close conformity between the applicator and skin surface. Air gaps can arise due to the irregular shape of the ear, potentially compromising dose coverage. This study evaluates the dosimetric impact of air gaps in HDR IRT for non-melanoma skin cancer (NMSC) of the ear. <b>Methods:</b> Ten patients treated with contact IRT using alginate as supporting material were retrospectively analyzed. Treatment plans were recalculated using both the TG-43 and the TG-186 formalism. CTV coverage and organ-at-risk dose parameters were evaluated within the two formalisms. <b>Results:</b> CTV coverage was comparable between algorithms (mean V95% 96.2% vs. 94.4%, V100% 89.6% vs. 86.7%, and V150% 2.6% vs. 2.5% for TG-43 vs. TG-186; <i>p</i> > 0.05), while the ipsilateral eye D2cc decreased from 4.0% (TG-43) to 3.2% (TG-186). In silico simulations showed that increasing air gaps reduced skin dose progressively (up to ~15% at 5 mm), whereas alginate thickness produced only a mild dose increase (<5%) across the tested range. Overall, small air pockets (<1 mm) did not substantially alter global dosimetric metrics, although local underdosage may occur at gap locations. <b>Conclusions:</b> This study underscores the importance of accounting for material heterogeneities and geometric uncertainties in anatomically complex regions through advanced dose calculation algorithms.

Journal of Clinical MedicineVol. 14(21)
Università Cattolica del Sacro Cuore (IT), Università degli Studi eCampus (IT), Agostino Gemelli University Polyclinic (IT), Advanced Radiation Therapy (United States) (US), Bambino Gesù Children's Hospital (IT)
Università Cattolica del Sacro Cuore
Openalex Percentile: Top 58%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.