An Exploratory Study on Vertical Extension with Inter-Story Isolation as a Sustainable Integrated Seismic and Energy Retrofit Strategy

The sustainable rehabilitation of existing buildings is essential to achieve urban resilience, resource efficiency and seismic risk reduction. This study investigates an integrated retrofit strategy that combines vertical extension with inter-story isolation to simultaneously enhance seismic performance and energy efficiency, creating additional usable space without additional land consumption. The inter-story isolation mechanism reduces seismic demand by decoupling a new and existing structure and introducing beneficial damping effects, whereas vertical extension improves a building’s envelope to reduce energy demands for heating and cooling. A tailored design methodology for integrated intervention is presented, according to which, for the structural part, a two-degrees-of-freedom dynamic model is adopted to design the characteristics of the isolation layer. The methodology is applied to a case-study building located in L’Aquila, Italy, where two alternative vertical extensions, one rigid and one lightweight, are analyzed. Time-history analyses and energy simulations for annual primary energy demand are carried out to assess the structural and thermal performance of the integrated retrofit. The results indicate that the proposed solution can reduce top-floor acceleration by up to 35%, inter-story drift by 30–35%, base shear by over 30% and primary energy demand by 11%, demonstrating its effectiveness in improving both seismic safety and energy performance. The main novelty of this study lies in the systematic integration of inter-story isolation with building envelope enhancement through vertical extension, offering a unified design framework that merges structural and energy retrofitting objectives into a single sustainable intervention.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-10-31
DOI
https://doi.org/10.3390/su17219713
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Exploratory Study on Vertical Extension with Inter-Story Isolation as a Sustainable Integrated Seismic and Energy Retrofit Strategy

Filippo Busato, Rosaria Parente, Michela Basili
Sustainability
Seismic Performance and Analysis
article

An Exploratory Study on Vertical Extension with Inter-Story Isolation as a Sustainable Integrated Seismic and Energy Retrofit Strategy

Filippo Busato, Rosaria Parente, Michela Basili
article en

Abstract

The sustainable rehabilitation of existing buildings is essential to achieve urban resilience, resource efficiency and seismic risk reduction. This study investigates an integrated retrofit strategy that combines vertical extension with inter-story isolation to simultaneously enhance seismic performance and energy efficiency, creating additional usable space without additional land consumption. The inter-story isolation mechanism reduces seismic demand by decoupling a new and existing structure and introducing beneficial damping effects, whereas vertical extension improves a building’s envelope to reduce energy demands for heating and cooling. A tailored design methodology for integrated intervention is presented, according to which, for the structural part, a two-degrees-of-freedom dynamic model is adopted to design the characteristics of the isolation layer. The methodology is applied to a case-study building located in L’Aquila, Italy, where two alternative vertical extensions, one rigid and one lightweight, are analyzed. Time-history analyses and energy simulations for annual primary energy demand are carried out to assess the structural and thermal performance of the integrated retrofit. The results indicate that the proposed solution can reduce top-floor acceleration by up to 35%, inter-story drift by 30–35%, base shear by over 30% and primary energy demand by 11%, demonstrating its effectiveness in improving both seismic safety and energy performance. The main novelty of this study lies in the systematic integration of inter-story isolation with building envelope enhancement through vertical extension, offering a unified design framework that merges structural and energy retrofitting objectives into a single sustainable intervention.

SustainabilityVol. 17(21)
Mercatorum University (IT)
Openalex Percentile: Top 66%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Exploratory Study on Vertical Extension with Inter-Story Isolation as a Sustainable Integrated Seismic and Energy Retrofit Strategy — Filippo Busato, Rosaria Parente, et al. · Sustainability (2025) | TGRS Research Map | TGRS