An Integrated Approach for Power Quality Monitoring in Transmission and Distribution Systems: The Italian Scenario

This paper presents an integrated approach to power quality monitoring across Italian transmission and distribution systems. The proposed methodology combines datasets from the Italian transmission system operator, Terna, and from the QuEEN monitoring system developed by RSE, which collects power quality information in terms of voltage events and variations on medium voltage busbars in primary substations. The integration enables a unified SQL-based database architecture that supports advanced statistical analysis and cross-layer event correlation. Two case studies are presented considering a 14-years observation period: i) the evaluation of the selectivity of the protection systems carried out by analyzing the number of load disconnections per failure; ii) the investigation of the correlation between high voltage outages and medium voltage interruptions recorded by QuEEN measurement units. Results highlight a gradual decreasing trend in system selectivity and a significant match between high and medium voltage events, highlighting the benefits brought by an integrated monitoring for reliability assessment and predictive maintenance.

Authors

Institutions

Publication Details

Published
2025-09-24
DOI
https://doi.org/10.1109/amps66841.2025.11219908
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Integrated Approach for Power Quality Monitoring in Transmission and Distribution Systems: The Italian Scenario

Sergio Toscani, Alessandra Moschetti, Liliana Tenti, Christian Laurano et al.
Power Systems Fault Detection
article

An Integrated Approach for Power Quality Monitoring in Transmission and Distribution Systems: The Italian Scenario

Sergio Toscani, Alessandra Moschetti, Liliana Tenti, Christian Laurano, Riccardo Chiumeo, Michele Zanoni, Massimo Volta, Loredana Cristaldi
article en

Abstract

This paper presents an integrated approach to power quality monitoring across Italian transmission and distribution systems. The proposed methodology combines datasets from the Italian transmission system operator, Terna, and from the QuEEN monitoring system developed by RSE, which collects power quality information in terms of voltage events and variations on medium voltage busbars in primary substations. The integration enables a unified SQL-based database architecture that supports advanced statistical analysis and cross-layer event correlation. Two case studies are presented considering a 14-years observation period: i) the evaluation of the selectivity of the protection systems carried out by analyzing the number of load disconnections per failure; ii) the investigation of the correlation between high voltage outages and medium voltage interruptions recorded by QuEEN measurement units. Results highlight a gradual decreasing trend in system selectivity and a significant match between high and medium voltage events, highlighting the benefits brought by an integrated monitoring for reliability assessment and predictive maintenance.

Ricerca sul Sistema Energetico (Italy) (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 59%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.