A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

• A co-simulation framework was developed to evaluate performance of a cooling blanket. • The framework integrates a building thermal model, a non-uniform and transient thermal comfort model, and a cooling blanket model. • The cooling blanket reduced thermal discomfort hours by up to 95.3 % with only 129.7 Wh of electricity use per day. • Huge energy-saving potential of cooling the human body directly instead of the entire building. Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Authors

Institutions

Publication Details

Journal
Building and Environment
Published
2025-11-03
DOI
https://doi.org/10.1016/j.buildenv.2025.113925
Citations
1
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Nathaniel Jones, Yilin Jiang, X. Zhang, Sumanjeet Kaur et al.
1 citations
Building and Environment
Geothermal Energy Systems and Applications
0.36
article

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Nathaniel Jones, Yilin Jiang, X. Zhang, Sumanjeet Kaur, Tianzhen Hong, Kaiyu Sun, Hui Zhang
article en
1 citations

Abstract

• A co-simulation framework was developed to evaluate performance of a cooling blanket. • The framework integrates a building thermal model, a non-uniform and transient thermal comfort model, and a cooling blanket model. • The cooling blanket reduced thermal discomfort hours by up to 95.3 % with only 129.7 Wh of electricity use per day. • Huge energy-saving potential of cooling the human body directly instead of the entire building. Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Building and EnvironmentVol. 288
Lawrence Berkeley National Laboratory (US), Arup Group (United States) (US), University of California, Berkeley (US)
Openalex Percentile: Top 37%
Geothermal Energy Systems and Applications
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.