Monitoring Vaccine-Induced Antibody Levels Using Carbon Nanotube-Based Field-Effect Transistors

Vaccines are powerful public health tools to protect against emerging infectious pathogens. Multiple vaccine doses are typically required to achieve robust protection that is often mediated by the induction of pathogen-specific antibodies. Thus, monitoring the levels of vaccine-induced antibodies in immunized individuals is crucial to ensuring vaccine effectiveness and compliance. However, existing antibody-detection techniques are resource- and time-inefficient, highlighting the need for improved technologies for monitoring vaccine-induced antibody levels. Here, we developed a field-effect transistor (FET) biosensor platform based on antigen-functionalized semiconducting single-walled carbon nanotubes (SWCNTs) for the rapid and convenient detection of pathogen-specific antibodies. Our antibody sensor platform was designed to produce robust signals with a high signal-to-noise ratio upon antigen-antibody interactions altering the electrical conductivity of interconnected SWCNTs. Key physicoelectrochemical characteristics of our SWCNT FET biosensor were validated by atomic force microscopy (AFM), scanning electron microscopy (SEM), Raman spectroscopy, and FET measurements. Robust and rapid antibody detection capability of our SWCNT FET biosensor platform was demonstrated by measuring virus-specific antibodies (e.g., anti-hemagglutinin (anti-HA), anti-SARS-CoV-2 nucleocapsid (anti-N), and anti-SARS-CoV-2 spike (anti-S) antibodies) in different systems. Our nanoelectronic sensor platform was able to detect these antibodies in a wide linear concentration range of 100 ag/mL to 100 ng/mL. Owing to the direct attachment of the corresponding antigens to SWCNTs, desirable limits of detection of 0.20 and 20.6 ag/mL were obtained for the detection of anti-HA and anti-S antibodies, respectively. Together, our SWCNT FET biosensor platform offers a next-generation antibody detection technology capable of low-cost, rapid, accessible, and convenient monitoring of vaccine-induced antibodies.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-11-03
DOI
https://doi.org/10.1021/acs.analchem.5c03817
Primary Topic
Nanowire Synthesis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Vaccine-Induced Antibody Levels Using Carbon Nanotube-Based Field-Effect Transistors

Alexander Star, Amir Amiri, Ashish Dhayani, Louis D. Falo et al.
Analytical Chemistry
Nanowire Synthesis and Applications
article

Monitoring Vaccine-Induced Antibody Levels Using Carbon Nanotube-Based Field-Effect Transistors

Alexander Star, Amir Amiri, Ashish Dhayani, Louis D. Falo, Stephen C. Balmert, Wenting Shao, Emrullah Korkmaz, Zidao Zeng
article en

Abstract

Vaccines are powerful public health tools to protect against emerging infectious pathogens. Multiple vaccine doses are typically required to achieve robust protection that is often mediated by the induction of pathogen-specific antibodies. Thus, monitoring the levels of vaccine-induced antibodies in immunized individuals is crucial to ensuring vaccine effectiveness and compliance. However, existing antibody-detection techniques are resource- and time-inefficient, highlighting the need for improved technologies for monitoring vaccine-induced antibody levels. Here, we developed a field-effect transistor (FET) biosensor platform based on antigen-functionalized semiconducting single-walled carbon nanotubes (SWCNTs) for the rapid and convenient detection of pathogen-specific antibodies. Our antibody sensor platform was designed to produce robust signals with a high signal-to-noise ratio upon antigen-antibody interactions altering the electrical conductivity of interconnected SWCNTs. Key physicoelectrochemical characteristics of our SWCNT FET biosensor were validated by atomic force microscopy (AFM), scanning electron microscopy (SEM), Raman spectroscopy, and FET measurements. Robust and rapid antibody detection capability of our SWCNT FET biosensor platform was demonstrated by measuring virus-specific antibodies (e.g., anti-hemagglutinin (anti-HA), anti-SARS-CoV-2 nucleocapsid (anti-N), and anti-SARS-CoV-2 spike (anti-S) antibodies) in different systems. Our nanoelectronic sensor platform was able to detect these antibodies in a wide linear concentration range of 100 ag/mL to 100 ng/mL. Owing to the direct attachment of the corresponding antigens to SWCNTs, desirable limits of detection of 0.20 and 20.6 ag/mL were obtained for the detection of anti-HA and anti-S antibodies, respectively. Together, our SWCNT FET biosensor platform offers a next-generation antibody detection technology capable of low-cost, rapid, accessible, and convenient monitoring of vaccine-induced antibodies.

Analytical ChemistryVol. 97(49)
University of Pittsburgh (US), Southern California Clinical and Translational Science Institute (US), McGowan Institute for Regenerative Medicine (US)
Openalex Percentile: Top 69%
Nanowire Synthesis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.