Analysis of Positive and Negative Lightning Impulse Discharge Characteristics in Long Air Gaps

Lightning is a common cause of failure in high-voltage transmission lines. This paper uses physical models of positive and negative discharges to analyze the differences in discharge characteristics between rod–plane and conductor–tower gaps. It also explores the influence of different tower structures on the discharge process. The simulation results show that negative leaders develop in a stepped manner and progress rapidly, while positive leaders develop continuously and progress more slowly. Under the same lightning impulse voltage level, negative discharges exhibit higher breakdown voltages. The development speed of positive discharges is mainly influenced by the applied voltage, while negative discharges are less affected by the applied voltage. For the same gap distance, the 50% breakdown voltages in the conductor–tower model are significantly higher than those in the rod–plane model for both polarities. Additionally, under shorter gap conditions, negative discharges may not show distinct stepped characteristics. This study provides theoretical guidance and practical references for lightning protection design and engineering applications in high-voltage transmission lines.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-10-31
DOI
https://doi.org/10.3390/en18215746
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Positive and Negative Lightning Impulse Discharge Characteristics in Long Air Gaps

Ruifeng Zhu, Yun Zhang, Yuxi Dong, Xinru Li et al.
Energies
Lightning and Electromagnetic Phenomena
article

Analysis of Positive and Negative Lightning Impulse Discharge Characteristics in Long Air Gaps

Ruifeng Zhu, Yun Zhang, Yuxi Dong, Xinru Li, J.F. Nie, Jiachen Gao, Zhenxin Zhong
article en

Abstract

Lightning is a common cause of failure in high-voltage transmission lines. This paper uses physical models of positive and negative discharges to analyze the differences in discharge characteristics between rod–plane and conductor–tower gaps. It also explores the influence of different tower structures on the discharge process. The simulation results show that negative leaders develop in a stepped manner and progress rapidly, while positive leaders develop continuously and progress more slowly. Under the same lightning impulse voltage level, negative discharges exhibit higher breakdown voltages. The development speed of positive discharges is mainly influenced by the applied voltage, while negative discharges are less affected by the applied voltage. For the same gap distance, the 50% breakdown voltages in the conductor–tower model are significantly higher than those in the rod–plane model for both polarities. Additionally, under shorter gap conditions, negative discharges may not show distinct stepped characteristics. This study provides theoretical guidance and practical references for lightning protection design and engineering applications in high-voltage transmission lines.

EnergiesVol. 18(21)
Hunan University (CN), China Southern Power Grid (China) (CN)
China Southern Power Grid
Openalex Percentile: Top 78%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Positive and Negative Lightning Impulse Discharge Characteristics in Long Air Gaps — Ruifeng Zhu, Yun Zhang, et al. · Energies (2025) | TGRS Research Map | TGRS