Retrofitting for Energy Efficiency Improvement Using Kinetic Façades in Residential Buildings: A Case Study from Saudi Arabia

Kinetic façades represent a climate-responsive design solution that improves building adaptability by responding to seasonal needs such as daylighting and shading. They offer an attractive retrofit strategy that improves both the esthetics and environmental performance of buildings. This study investigated the integration of an origami-inspired kinetic façade into a student dormitory building located in Dhahran, Saudi Arabia. Using numerical simulations, 35 façade configurations were analyzed under varying conditions of façade orientations, closure ratios (from 5% to 95%), and cavity depths (from 20 cm to 100 cm). The findings highlight the critical impact of kinetic façade design characteristics on daylight availability and solar exposure and the required trade-off between these two variables. In this context, this study observed that at higher façade closure ratios, increasing cavity depth could effectively mitigate daylight reduction by promoting reflected daylight penetration inside the cavity. As for heat gains and cooling load reduction, mid-range façade closure, 50 cm in this study, achieved balanced performance across the three examined orientations. However, the southern façade showed slightly higher efficiency compared to the eastern and western façades, which achieved lower cooling reductions and showed a similar UDI compromise. Thus, a dynamic façade operation is recommended, where higher closure ratios could be applied during peak solar hours on the east in the morning and the west in the afternoon to maximize cooling savings, while moderate closure ratios can be maintained on the south to preserve daylight. Future work should incorporate real-time climatic data and smart control technologies to further optimize kinetic façade performance.

Authors

Institutions

Publication Details

Journal
Eng—Advances in Engineering
Published
2025-10-31
DOI
https://doi.org/10.3390/eng6110292
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrofitting for Energy Efficiency Improvement Using Kinetic Façades in Residential Buildings: A Case Study from Saudi Arabia

Ziad Ashour, Ahmed Abd El Fattah, Omar S. Asfour, Taufiq I. Ismail et al.
Eng—Advances in Engineering
Building Energy and Comfort Optimization
article

Retrofitting for Energy Efficiency Improvement Using Kinetic Façades in Residential Buildings: A Case Study from Saudi Arabia

Ziad Ashour, Ahmed Abd El Fattah, Omar S. Asfour, Taufiq I. Ismail, Godman O. Agbo
article en

Abstract

Kinetic façades represent a climate-responsive design solution that improves building adaptability by responding to seasonal needs such as daylighting and shading. They offer an attractive retrofit strategy that improves both the esthetics and environmental performance of buildings. This study investigated the integration of an origami-inspired kinetic façade into a student dormitory building located in Dhahran, Saudi Arabia. Using numerical simulations, 35 façade configurations were analyzed under varying conditions of façade orientations, closure ratios (from 5% to 95%), and cavity depths (from 20 cm to 100 cm). The findings highlight the critical impact of kinetic façade design characteristics on daylight availability and solar exposure and the required trade-off between these two variables. In this context, this study observed that at higher façade closure ratios, increasing cavity depth could effectively mitigate daylight reduction by promoting reflected daylight penetration inside the cavity. As for heat gains and cooling load reduction, mid-range façade closure, 50 cm in this study, achieved balanced performance across the three examined orientations. However, the southern façade showed slightly higher efficiency compared to the eastern and western façades, which achieved lower cooling reductions and showed a similar UDI compromise. Thus, a dynamic façade operation is recommended, where higher closure ratios could be applied during peak solar hours on the east in the morning and the west in the afternoon to maximize cooling savings, while moderate closure ratios can be maintained on the south to preserve daylight. Future work should incorporate real-time climatic data and smart control technologies to further optimize kinetic façade performance.

Eng—Advances in EngineeringVol. 6(11)
King Fahd University of Petroleum and Minerals (SA)
King Fahd University of Petroleum and Minerals
Openalex Percentile: Top 65%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.