Dynamic Cerebral Perfusion Electrical Impedance Tomography: A Neuroimaging Technique for Bedside Cerebral Perfusion Monitoring During Mannitol Dehydration
Mannitol dehydration is routinely used to prevent and treat cerebral damage after total aortic arch replacement (TAAR), but existing neuroimaging technologies cannot achieve bedside real-time quantitative assessment of its impact on cerebral perfusion in different patients. This study applied dynamic cerebral perfusion electrical impedance tomography (DCP-EIT), a non-invasive neuroimaging technique, for bedside cerebral perfusion monitoring in TAAR patients during dehydration. Seventeen patients with normal neurological function and nineteen with neurological dysfunction (ND) were enrolled. The variation patterns and differences in perfusion impedance, images, and the relative ratios (RY) of mean perfusion velocity (MV), height of systolic wave (Hs), inflow volume velocity (IV), and angle between the ascending branch and baseline (A<sub>ab</sub>) were analyzed. Results showed DCP-EIT could visualize cerebral perfusion changes, with detected poorly perfused regions showing good consistency with ischemic areas identified by computed tomography (CT). RY of normal patients fluctuated around 0.97-1.04, with no significant difference from baseline. RY of ND patients peaked at 14-20 min after dehydration and remained higher than baseline even at 100 min (<i>p</i> < 0.001). DCP-EIT holds potential to optimize individualized cerebral protection strategies for other cerebral damage scenarios and neurocritical care.
Authors
- Lihua Hou (ORCID: https://orcid.org/0000-0003-3644-2612)
- Yitong Guo (ORCID: https://orcid.org/0000-0003-3531-2103)
- Zhenxiao Jin (ORCID: https://orcid.org/0000-0003-0586-816X)
- Weixun Duan (ORCID: https://orcid.org/0000-0003-4475-7067)
- Canhua Xu (ORCID: https://orcid.org/0000-0003-0728-3544)
- Weice Wang (ORCID: https://orcid.org/0009-0003-5584-1210)
- Rong Zhao (ORCID: https://orcid.org/0009-0009-4276-9823)
- Mingxu Zhu (ORCID: https://orcid.org/0009-0007-1574-4108)
- Xuetao Shi (ORCID: https://orcid.org/0000-0002-3552-9479)
- Yu Wang (ORCID: https://orcid.org/0009-0004-8005-2827)
Institutions
- Northwestern Polytechnical University (CN)
- Tang Du Hospital (CN)
- Xijing Hospital (CN)
- Air Force Medical University (CN)
Publication Details
- Journal
- Bioengineering
- Published
- 2025-10-31
- DOI
- https://doi.org/10.3390/bioengineering12111187
- Primary Topic
- Electrical and Bioimpedance Tomography
- Type
- article
- Field-Weighted Citation Impact
- 0.00