3D-Printed Microneedles with Controlled Structures for Drug Delivery Study in an Ex Vivo Model

MN arrays are highly beneficial for transdermal drug delivery, primarily due to reduced pain and improved compliance. However, complex processing and restricted design freedom limit traditional fabrication. We utilized stereolithography (SLA) 3D printing as a breakthrough method to achieve the one-step production of MN arrays with customized geometries (structure, size, tip angle), enabling tunable release profiles and eliminating cumbersome manufacturing steps. After fabricating conical and grooved MN arrays and validating them in an ex vivo porcine skin model, we confirmed their functionality. Notably, the grooved design provided excellent penetration, requiring only 2.2 N of force for full insertion (at 18.92° tip angle), and demonstrated an enhanced drug loading capacity of 4.8 μg released over 2 h. These results underscore the significant potential of 3D-printed, channel-structured MN arrays as a new generation of high-performance transdermal delivery devices.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-10-31
DOI
https://doi.org/10.3390/mi16111249
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-Printed Microneedles with Controlled Structures for Drug Delivery Study in an Ex Vivo Model

Wei Dong, Fu Liu, Xiang Song, Wei Yang
Micromachines
Advancements in Transdermal Drug Delivery
article

3D-Printed Microneedles with Controlled Structures for Drug Delivery Study in an Ex Vivo Model

Wei Dong, Fu Liu, Xiang Song, Wei Yang
article en

Abstract

MN arrays are highly beneficial for transdermal drug delivery, primarily due to reduced pain and improved compliance. However, complex processing and restricted design freedom limit traditional fabrication. We utilized stereolithography (SLA) 3D printing as a breakthrough method to achieve the one-step production of MN arrays with customized geometries (structure, size, tip angle), enabling tunable release profiles and eliminating cumbersome manufacturing steps. After fabricating conical and grooved MN arrays and validating them in an ex vivo porcine skin model, we confirmed their functionality. Notably, the grooved design provided excellent penetration, requiring only 2.2 N of force for full insertion (at 18.92° tip angle), and demonstrated an enhanced drug loading capacity of 4.8 μg released over 2 h. These results underscore the significant potential of 3D-printed, channel-structured MN arrays as a new generation of high-performance transdermal delivery devices.

MicromachinesVol. 16(11)
North University of China (CN), Shanxi Medical University (CN), Second Hospital of Shanxi Medical University (CN), Beihang University (CN)
Openalex Percentile: Top 75%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

3D-Printed Microneedles with Controlled Structures for Drug Delivery Study in an Ex Vivo Model — Wei Dong, Fu Liu, et al. · Micromachines (2025) | TGRS Research Map | TGRS