Development of radioprotective side shield attached to radioprotective glasses for reducing eye lens dose of endoscopists during endoscopic retrograde cholangiopancreatography: a phantom study

The use of radioprotective glasses alone may not reduce radiation sufficiently to protect the eyes of endoscopists performing endoscopic retrograde cholangiopancreatography (ERCP). In this study, we aimed to develop a radioprotective side shield that could be attached to radioprotective glasses. Air kerma was measured at the lens surface of an endoscopist phantom using optically stimulated luminescence dosimeters in an arrangement that simulated ERCP. The protective effect of the radioprotective side shield was evaluated by changing three factors: the number of sheets to be layered from 1 to 5, the front-side length of the sheet from 6 to 10 cm, and the rear-side length of the sheet from 5 to 7 cm. By increasing the front length of the sheets to 8 cm, their rear length to 6 cm, and increasing the number of sheets to three with a lead equivalent of 0.14 ± 0.02 mmPb, the air kerma on the ocular surface could be reduced considerably; hence, these changes were implemented. This achieved a dose reduction of 48.2-87.3% compared with the use of radioprotective glasses alone, especially when the endoscopist phantom was rotated 60° and 75° from the direction directly opposite to that of the patient phantom. The results suggest that radioprotective side shields can reduce radiation exposure in the eyes of endoscopists by < 0.03 mGy in 10-min fluoroscopy under most conditions during ERCP.

Authors

Institutions

Publication Details

Journal
Radiological Physics and Technology
Published
2025-11-03
DOI
https://doi.org/10.1007/s12194-025-00983-2
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of radioprotective side shield attached to radioprotective glasses for reducing eye lens dose of endoscopists during endoscopic retrograde cholangiopancreatography: a phantom study

Kosuke Matsubara, Kazuhiro Yamaguchi, Kotaro Fukushima
1 citations
Radiological Physics and Technology
Radiation Dose and Imaging
1.36
article

Development of radioprotective side shield attached to radioprotective glasses for reducing eye lens dose of endoscopists during endoscopic retrograde cholangiopancreatography: a phantom study

Kosuke Matsubara, Kazuhiro Yamaguchi, Kotaro Fukushima
article en
1 citations

Abstract

The use of radioprotective glasses alone may not reduce radiation sufficiently to protect the eyes of endoscopists performing endoscopic retrograde cholangiopancreatography (ERCP). In this study, we aimed to develop a radioprotective side shield that could be attached to radioprotective glasses. Air kerma was measured at the lens surface of an endoscopist phantom using optically stimulated luminescence dosimeters in an arrangement that simulated ERCP. The protective effect of the radioprotective side shield was evaluated by changing three factors: the number of sheets to be layered from 1 to 5, the front-side length of the sheet from 6 to 10 cm, and the rear-side length of the sheet from 5 to 7 cm. By increasing the front length of the sheets to 8 cm, their rear length to 6 cm, and increasing the number of sheets to three with a lead equivalent of 0.14 ± 0.02 mmPb, the air kerma on the ocular surface could be reduced considerably; hence, these changes were implemented. This achieved a dose reduction of 48.2-87.3% compared with the use of radioprotective glasses alone, especially when the endoscopist phantom was rotated 60° and 75° from the direction directly opposite to that of the patient phantom. The results suggest that radioprotective side shields can reduce radiation exposure in the eyes of endoscopists by < 0.03 mGy in 10-min fluoroscopy under most conditions during ERCP.

Radiological Physics and TechnologyVol. 19(1)
Kanazawa University (JP), Kanazawa Medical University (JP), Toyota Kosei Hospital (JP), Fukui CardioVascular Center (JP)
Kanazawa University, Japan Society for the Promotion of Science
Openalex Percentile: Top 14%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.