Abstract 4367324: Artificial Intelligence ECG Model To Reduce False-Positive STEMI Alerts in the Emergency Department

Introduction: Current STEMI alert pathways triggered in the emergency department often result in high false-positive rates and frequent cancellations by cardiology. AI-based ECG analysis may improve diagnostic accuracy and resource use in suspected occlusive myocardial infarction (OMI). Objective: To evaluate the predictive performance of an AI deep learning ECG algorithm in identifying OMI among ED-triggered STEMI Alerts (SAs), including subgroup analysis in common STEMI mimic patterns of LVH and LBBB. Methods: We retrospectively analyzed ED-triggered SAs in adult patients at a large, urban, tertiary academic medical center from January 1 to October 31, 2024. Alerts were activated by ED physicians and assessed by cardiologists for emergent catheterization lab activation (CLA). Cases initiated by EMS or post-cardiac arrest were excluded. Pre-alert ECGs were analyzed by the Queen of Hearts (QoH) AI model and classified as OMI or non-OMI. True OMI was defined by either (1) an acute culprit lesion with TIMI 0–2 flow, (2) an acute non-occlusive culprit with large infarct size (hsTn >1000 ng/L), or (3) no angiography but highly elevated hsTn with a new echocardiographic wall motion abnormality. QoH model performance was compared to standard clinical interpretation, including cardiologist-determined CLA. Results: Of the 192 SAs, 29 were true OMIs, reflecting an 85% false-positive rate. Emergent CLA was performed in 32 cases, with 24 confirmed OMIs (Sn 83%, Sp 95%). Five OMIs occurred among the 160 cancelled alerts. The QoH model identified 42 cases as OMI, correctly detecting 25 of 29 (Sn 86%, Sp 89%), including 3 of the 5 missed by cardiology. Among 58 SAs with LVH, QoH identified both true OMIs (Sn 100%, Sp 95%). None of the 13 LBBB cases were OMI (Sp 92%). Conclusion: The QoH AI model has the potential to substantially reduce false-positive ED-triggered STEMI alerts and exhibited diagnostic performance comparable to cardiologist-determined CLA. Notably, QoH identified OMI cases missed by standard clinical evaluation and was highly accurate in patients with LVH—a common STEMI mimic in this population. These findings support the potential of AI-assisted ECG interpretation to enhance triage accuracy and optimize resource utilization in acute cardiac care.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4367324
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4367324: Artificial Intelligence ECG Model To Reduce False-Positive STEMI Alerts in the Emergency Department

Heba Mesbah, Stephen Boone, Adam Davis
Circulation
Cardiac Arrest and Resuscitation
article

Abstract 4367324: Artificial Intelligence ECG Model To Reduce False-Positive STEMI Alerts in the Emergency Department

Heba Mesbah, Stephen Boone, Adam Davis
article en

Abstract

Introduction: Current STEMI alert pathways triggered in the emergency department often result in high false-positive rates and frequent cancellations by cardiology. AI-based ECG analysis may improve diagnostic accuracy and resource use in suspected occlusive myocardial infarction (OMI). Objective: To evaluate the predictive performance of an AI deep learning ECG algorithm in identifying OMI among ED-triggered STEMI Alerts (SAs), including subgroup analysis in common STEMI mimic patterns of LVH and LBBB. Methods: We retrospectively analyzed ED-triggered SAs in adult patients at a large, urban, tertiary academic medical center from January 1 to October 31, 2024. Alerts were activated by ED physicians and assessed by cardiologists for emergent catheterization lab activation (CLA). Cases initiated by EMS or post-cardiac arrest were excluded. Pre-alert ECGs were analyzed by the Queen of Hearts (QoH) AI model and classified as OMI or non-OMI. True OMI was defined by either (1) an acute culprit lesion with TIMI 0–2 flow, (2) an acute non-occlusive culprit with large infarct size (hsTn >1000 ng/L), or (3) no angiography but highly elevated hsTn with a new echocardiographic wall motion abnormality. QoH model performance was compared to standard clinical interpretation, including cardiologist-determined CLA. Results: Of the 192 SAs, 29 were true OMIs, reflecting an 85% false-positive rate. Emergent CLA was performed in 32 cases, with 24 confirmed OMIs (Sn 83%, Sp 95%). Five OMIs occurred among the 160 cancelled alerts. The QoH model identified 42 cases as OMI, correctly detecting 25 of 29 (Sn 86%, Sp 89%), including 3 of the 5 missed by cardiology. Among 58 SAs with LVH, QoH identified both true OMIs (Sn 100%, Sp 95%). None of the 13 LBBB cases were OMI (Sp 92%). Conclusion: The QoH AI model has the potential to substantially reduce false-positive ED-triggered STEMI alerts and exhibited diagnostic performance comparable to cardiologist-determined CLA. Notably, QoH identified OMI cases missed by standard clinical evaluation and was highly accurate in patients with LVH—a common STEMI mimic in this population. These findings support the potential of AI-assisted ECG interpretation to enhance triage accuracy and optimize resource utilization in acute cardiac care.

CirculationVol. 152(Suppl_3)
Baylor College of Medicine (US), Friends United (US)
Openalex Percentile: Top 52%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.