Abstract 4366910: Multicenter Model to Predict Right Heart Failure After HeartMate 3 Left Ventricular Assist Device Implantation

Background: Right heart failure (RHF) is a serious complication of durable HeartMate 3 (HM3) left ventricular assist device (LVAD) therapy. We aimed to evaluate the incidence, predictors, and prognostic significance of RHF within 3 months following HM3 LVAD implantation among patients in a contemporary multicenter registry, utilizing preoperative imaging, hemodynamics, and medication variables in our analysis. Methods: Patients underwent HM3 LVAD implantation at 6 centers between 2015-2022. A multivariable logistic regression model was developed using least absolute shrinkage and selection operator (LASSO) for the variable selection process. Mechanical Circulatory Support-Academic Research Consortium definitions of early and late RHF were used. Results: Among 596 patients (median age 59 years, 25% female, 48% INTERMACS profiles 1 or 2), 195 (33%) developed RHF within 3 months of LVAD implantation. In multivariable analysis, the following preoperative variables were independently associated with an increased risk of RHF: severe right ventricular systolic dysfunction on echocardiogram (OR 1.78, p=0.036), VA ECMO (OR 3.45, p=0.002), and dobutamine use (OR 1.66, p=0.029). Additionally, standardized lower left ventricular end-diastolic diameter (OR 0.76 per SD increase, p=0.005) and higher mean pulmonary artery pressure (OR 1.23 per SD increase, p=0.032) were significantly associated with increased risk of RHF. Survival, censored for heart transplant and pump exchange, was significantly worse for patients experiencing RHF within 3 months compared to patients who did not develop this complication (75% vs. 90% at 1-year and 63% vs 71% at 4-years, p=0.003; Figure). Conclusions: RHF is common within the first 3 months of HM3 LVAD implantation and is associated with significantly greater mortality during long-term follow-up. We identified preoperative imaging, hemodynamics, and medication variables that can be used during evaluation and selection of candidates for LVAD therapy.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4366910
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4366910: Multicenter Model to Predict Right Heart Failure After HeartMate 3 Left Ventricular Assist Device Implantation

Noah Moss, Michael V. Genuardi, Arman Kilic, Omar Saeed et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4366910: Multicenter Model to Predict Right Heart Failure After HeartMate 3 Left Ventricular Assist Device Implantation

Noah Moss, Michael V. Genuardi, Arman Kilic, Omar Saeed, Himabindu Vidula, Samit Shah, Jinbo Chen, Min Zhao, Danyaal Moin
article en

Abstract

Background: Right heart failure (RHF) is a serious complication of durable HeartMate 3 (HM3) left ventricular assist device (LVAD) therapy. We aimed to evaluate the incidence, predictors, and prognostic significance of RHF within 3 months following HM3 LVAD implantation among patients in a contemporary multicenter registry, utilizing preoperative imaging, hemodynamics, and medication variables in our analysis. Methods: Patients underwent HM3 LVAD implantation at 6 centers between 2015-2022. A multivariable logistic regression model was developed using least absolute shrinkage and selection operator (LASSO) for the variable selection process. Mechanical Circulatory Support-Academic Research Consortium definitions of early and late RHF were used. Results: Among 596 patients (median age 59 years, 25% female, 48% INTERMACS profiles 1 or 2), 195 (33%) developed RHF within 3 months of LVAD implantation. In multivariable analysis, the following preoperative variables were independently associated with an increased risk of RHF: severe right ventricular systolic dysfunction on echocardiogram (OR 1.78, p=0.036), VA ECMO (OR 3.45, p=0.002), and dobutamine use (OR 1.66, p=0.029). Additionally, standardized lower left ventricular end-diastolic diameter (OR 0.76 per SD increase, p=0.005) and higher mean pulmonary artery pressure (OR 1.23 per SD increase, p=0.032) were significantly associated with increased risk of RHF. Survival, censored for heart transplant and pump exchange, was significantly worse for patients experiencing RHF within 3 months compared to patients who did not develop this complication (75% vs. 90% at 1-year and 63% vs 71% at 4-years, p=0.003; Figure). Conclusions: RHF is common within the first 3 months of HM3 LVAD implantation and is associated with significantly greater mortality during long-term follow-up. We identified preoperative imaging, hemodynamics, and medication variables that can be used during evaluation and selection of candidates for LVAD therapy.

CirculationVol. 152(Suppl_3)
Montefiore Medical Center (US), Medical University of South Carolina (US), Mount Sinai Medical Center (US), New York University (US), University of Pennsylvania (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.