Abstract 4368713: Implantable Intramyocardial Sensor for Continuous Monitoring of Ventricular Function

Background: Heart failure management increasingly requires accurate, continuous assessment of left ventricular (LV) function, including parameters such as systolic and end-diastolic pressure (LVSP, LVEDP). These metrics are typically measured intermittently using invasive catheterization, providing only point-in-time values rather than continuous hemodynamic monitoring. Currently, no established method exists for direct, long-term monitoring of LV pressures, limiting timely detection of decompensation and individualized therapy adjustment. Objective: To develop and validate an intramyocardial cardiac monitoring system enabling real-time estimation of LV function. Methods: A micro-electro-mechanical systems (MEMS) pressure sensor array was implanted into the LV free wall and integrated with a machine learning model trained to estimate intracardiac pressures from local myocardial dynamics. Validation was performed in acute swine experiments (n=3) under dobutamine stress, using intraventricular pressure-volume catheterization as the reference standard. Results: The system estimated LVSP and LVEDP with mean differences of 0.06 ± 5.3 mmHg and 0.15 ± 3.6 mmHg, respectively. Across all markers, the average coefficient of determination exceeded 0.85, indicating strong agreement. Conclusion: This MEMS-machine learning platform enables accurate, continuous estimation of LV function without the need for intra-cardiac instrumentation. Its compact design and real-time capabilities support its potential for even less invasive epicardial implementation, remote heart failure monitoring, and personalized therapy adjustment.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4368713
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4368713: Implantable Intramyocardial Sensor for Continuous Monitoring of Ventricular Function

Sigrid Schmitt, Attila Kiss, Francesco Moscato, Max Haberbusch et al.
Circulation
Cardiovascular Function and Risk Factors
article

Abstract 4368713: Implantable Intramyocardial Sensor for Continuous Monitoring of Ventricular Function

Sigrid Schmitt, Attila Kiss, Francesco Moscato, Max Haberbusch, Bruno Karl Podesser, Philipp Aigner, Peter Detemple
article en

Abstract

Background: Heart failure management increasingly requires accurate, continuous assessment of left ventricular (LV) function, including parameters such as systolic and end-diastolic pressure (LVSP, LVEDP). These metrics are typically measured intermittently using invasive catheterization, providing only point-in-time values rather than continuous hemodynamic monitoring. Currently, no established method exists for direct, long-term monitoring of LV pressures, limiting timely detection of decompensation and individualized therapy adjustment. Objective: To develop and validate an intramyocardial cardiac monitoring system enabling real-time estimation of LV function. Methods: A micro-electro-mechanical systems (MEMS) pressure sensor array was implanted into the LV free wall and integrated with a machine learning model trained to estimate intracardiac pressures from local myocardial dynamics. Validation was performed in acute swine experiments (n=3) under dobutamine stress, using intraventricular pressure-volume catheterization as the reference standard. Results: The system estimated LVSP and LVEDP with mean differences of 0.06 ± 5.3 mmHg and 0.15 ± 3.6 mmHg, respectively. Across all markers, the average coefficient of determination exceeded 0.85, indicating strong agreement. Conclusion: This MEMS-machine learning platform enables accurate, continuous estimation of LV function without the need for intra-cardiac instrumentation. Its compact design and real-time capabilities support its potential for even less invasive epicardial implementation, remote heart failure monitoring, and personalized therapy adjustment.

CirculationVol. 152(Suppl_3)
Fraunhofer Institute for Microengineering and Microsystems (DE), Medical University of Vienna (AT)
Openalex Percentile: Top 50%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.