Abstract 4360153: Adverse Events and Outcomes Among Patients with Temporary Mechanical Circulatory Support Devices Placed at Referring Versus Hub Cardiogenic Shock Centers

Introduction: Temporary mechanical support (tMCS) devices (intra-aortic balloon pump [IABP], Impella CP, Impella 5.5) are commonly used in cardiogenic shock (CS) and are often placed at regional centers (RC) to stabilize patients for transfer to a CS hub center (HC). Aims: To assess whether initial tMCS device placement for CS at an RC before transfer to HC is associated with more device-related adverse events (DRAEs) and worse outcomes than with initial device placement at a HC. Methods: All patients admitted to a single center from 8/2021 to 8/2023 with CS requiring tMCS were identified using CPT codes. Baseline characteristics, CS severity, DRAEs, and outcomes were collected. Outcomes included in-hospital mortality and “unfavorable outcome” (death prior to heart transplant, durable LVAD implant, or discharge). Patients were stratified by location of initial tMCS device placement (RC vs HC). Characteristics, DRAEs, and outcomes were compared. Multivariable logistic regression was performed to account for baseline differences. Sensitivity analyses were performed to assess consistency of results by device exposure. Results: 268 patients were included, 214 (79.9%) with initial device placed at HC and 54 (20.1%) at RC. The initial device was IABP in 54.1%, Impella CP in 28.0%, and Impella 5.5 in 17.9%. Median age was 60 (44, 67) years, 59.3% were Black, and 71.6% male (similar between groups). Compared to HC implanted patients, RC patients more commonly had non-ischemic CM (63% vs 37%, p=0.02), de novo HF-CS (41% vs 14%, p=0.02), and cardiac arrest (32% vs 11%; p<0.01) but less commonly had prior HFrEF (51% vs 69%, p=0.02) and kidney disease (9% vs 25%, p=0.01). RC implanted patients had more advanced CS (Stage E CS in 30% vs 8%; p<0.01). DRAEs were more common in RC than HC implanted patients (1.19 vs 0.46 events per patient-week on tMCS support; p<0.01)(Fig 1). RC implanted patients had higher unadjusted odds of in-hospital mortality and unfavorable outcome (Fig 2). This finding was similar after adjustment for baseline differences and CS etiology but no longer statistically significant after adjusting for CS severity and cardiac arrest. These findings were consistent in the sensitivity analyses among patients with any IABP and any Impella exposure. Conclusions: Patients with tMCS devices placed for CS at RC have more DRAEs and worse outcomes than those with initial device placed at a HC. The higher mortality in RC implanted patients may be due to greater CS severity.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4360153
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4360153: Adverse Events and Outcomes Among Patients with Temporary Mechanical Circulatory Support Devices Placed at Referring Versus Hub Cardiogenic Shock Centers

Jeffrey McMurray, Molly Silkowski, Anthony Carnicelli, Michael Varrone et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4360153: Adverse Events and Outcomes Among Patients with Temporary Mechanical Circulatory Support Devices Placed at Referring Versus Hub Cardiogenic Shock Centers

Jeffrey McMurray, Molly Silkowski, Anthony Carnicelli, Michael Varrone, Lucas Witer, Brady Gunn, Kelly Ohlrich, Ryan J. Tedford, Roxanne Mittelstaedt, Brian H. Houston, Arman Kilic, Zachary Patel, Janet D. Peller, Mathew J. Gregoski, Lindsey Bull, Stephanie Samani, Meg Ospina, Kaylen Dodson, Charlotte Marchell
article en

Abstract

Introduction: Temporary mechanical support (tMCS) devices (intra-aortic balloon pump [IABP], Impella CP, Impella 5.5) are commonly used in cardiogenic shock (CS) and are often placed at regional centers (RC) to stabilize patients for transfer to a CS hub center (HC). Aims: To assess whether initial tMCS device placement for CS at an RC before transfer to HC is associated with more device-related adverse events (DRAEs) and worse outcomes than with initial device placement at a HC. Methods: All patients admitted to a single center from 8/2021 to 8/2023 with CS requiring tMCS were identified using CPT codes. Baseline characteristics, CS severity, DRAEs, and outcomes were collected. Outcomes included in-hospital mortality and “unfavorable outcome” (death prior to heart transplant, durable LVAD implant, or discharge). Patients were stratified by location of initial tMCS device placement (RC vs HC). Characteristics, DRAEs, and outcomes were compared. Multivariable logistic regression was performed to account for baseline differences. Sensitivity analyses were performed to assess consistency of results by device exposure. Results: 268 patients were included, 214 (79.9%) with initial device placed at HC and 54 (20.1%) at RC. The initial device was IABP in 54.1%, Impella CP in 28.0%, and Impella 5.5 in 17.9%. Median age was 60 (44, 67) years, 59.3% were Black, and 71.6% male (similar between groups). Compared to HC implanted patients, RC patients more commonly had non-ischemic CM (63% vs 37%, p=0.02), de novo HF-CS (41% vs 14%, p=0.02), and cardiac arrest (32% vs 11%; p<0.01) but less commonly had prior HFrEF (51% vs 69%, p=0.02) and kidney disease (9% vs 25%, p=0.01). RC implanted patients had more advanced CS (Stage E CS in 30% vs 8%; p<0.01). DRAEs were more common in RC than HC implanted patients (1.19 vs 0.46 events per patient-week on tMCS support; p<0.01)(Fig 1). RC implanted patients had higher unadjusted odds of in-hospital mortality and unfavorable outcome (Fig 2). This finding was similar after adjustment for baseline differences and CS etiology but no longer statistically significant after adjusting for CS severity and cardiac arrest. These findings were consistent in the sensitivity analyses among patients with any IABP and any Impella exposure. Conclusions: Patients with tMCS devices placed for CS at RC have more DRAEs and worse outcomes than those with initial device placed at a HC. The higher mortality in RC implanted patients may be due to greater CS severity.

CirculationVol. 152(Suppl_3)
University of Charleston (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.