Abstract 4364510: Impella Support in Acute Severe Mitral Regurgitation With Cardiogenic Shock and Septal Injury–Related Heart Block

Background: Acute severe mitral regurgitation (MR) is a rare but life-threatening cause of cardiogenic shock, often resulting in multi-organ failure. Mechanical circulatory support (MCS) with Impella is infrequently used in this setting but may offer rapid stabilization as a bridge to surgery. However, device-related conduction system trauma remains underrecognized. Case: A 77-year-old woman with hypertension presented with acute dyspnea, new-onset atrial fibrillation, and a holosystolic murmur. Transesophageal echocardiography revealed a flail P2 scallop with acute severe MR and preserved ejection fraction. The left ventricular internal diameter was within normal limits but showed concentric hypertrophy. She developed cardiogenic shock with acute kidney and liver injury. Impella CP was initiated to augment forward flow and unload the LV using a target P-7 setting, as intra-aortic balloon pump was deemed insufficient due to its afterload-reducing mechanism. Over 48 hours, end-organ function improved markedly. During support, frequent ventricular ectopy was observed. At mitral valve replacement, septal bruising was noted despite appropriately shallow device positioning (3.2 cm), and intermittent complete heart block required temporary epicardial pacing. A permanent dual-chamber pacemaker was placed the next day due to persistent conduction issues. She recovered well and was discharged home ambulatory. Discussion: Although intra-aortic balloon pump remains the most common MCS in acute MR due to ease of use, Impella may provide superior forward flow when LV unloading is needed. While complete heart block is recognized post-mitral surgery, its preoperative onset here implicates device-induced septal injury. The patient’s small, concentrically remodeled LV may have increased septal vulnerability. Though rarely reported, conduction disturbances from axial-flow MCS have been sparsely described and may be underrecognized. Conclusion: This case highlights both the utility and risks of Impella in acute MR with cardiogenic shock. Vigilance for conduction disturbances is critical—even with proper positioning—particularly in patients with compact ventricular geometry. Early recognition and pacing readiness may be key to favorable outcomes.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4364510
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4364510: Impella Support in Acute Severe Mitral Regurgitation With Cardiogenic Shock and Septal Injury–Related Heart Block

Attila Roka, Mason Klisares, Mariam Khabsa, Amjad Kabach et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4364510: Impella Support in Acute Severe Mitral Regurgitation With Cardiogenic Shock and Septal Injury–Related Heart Block

Attila Roka, Mason Klisares, Mariam Khabsa, Amjad Kabach, Ali J. Khiabani, May Li-Jedras
article en

Abstract

Background: Acute severe mitral regurgitation (MR) is a rare but life-threatening cause of cardiogenic shock, often resulting in multi-organ failure. Mechanical circulatory support (MCS) with Impella is infrequently used in this setting but may offer rapid stabilization as a bridge to surgery. However, device-related conduction system trauma remains underrecognized. Case: A 77-year-old woman with hypertension presented with acute dyspnea, new-onset atrial fibrillation, and a holosystolic murmur. Transesophageal echocardiography revealed a flail P2 scallop with acute severe MR and preserved ejection fraction. The left ventricular internal diameter was within normal limits but showed concentric hypertrophy. She developed cardiogenic shock with acute kidney and liver injury. Impella CP was initiated to augment forward flow and unload the LV using a target P-7 setting, as intra-aortic balloon pump was deemed insufficient due to its afterload-reducing mechanism. Over 48 hours, end-organ function improved markedly. During support, frequent ventricular ectopy was observed. At mitral valve replacement, septal bruising was noted despite appropriately shallow device positioning (3.2 cm), and intermittent complete heart block required temporary epicardial pacing. A permanent dual-chamber pacemaker was placed the next day due to persistent conduction issues. She recovered well and was discharged home ambulatory. Discussion: Although intra-aortic balloon pump remains the most common MCS in acute MR due to ease of use, Impella may provide superior forward flow when LV unloading is needed. While complete heart block is recognized post-mitral surgery, its preoperative onset here implicates device-induced septal injury. The patient’s small, concentrically remodeled LV may have increased septal vulnerability. Though rarely reported, conduction disturbances from axial-flow MCS have been sparsely described and may be underrecognized. Conclusion: This case highlights both the utility and risks of Impella in acute MR with cardiogenic shock. Vigilance for conduction disturbances is critical—even with proper positioning—particularly in patients with compact ventricular geometry. Early recognition and pacing readiness may be key to favorable outcomes.

CirculationVol. 152(Suppl_3)
Creighton University (US), Washington University in St. Louis (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.