Abstract 4362750: Electrocardiogram-Based Artificial Intelligence to Improve the Efficiency of Atrial Fibrillation Screening: A VITAL-AF Trial Analysis

Background: Atrial fibrillation (AF) is common and highly morbid. AF screening may detect AF earlier and facilitate preventive measures (e.g., anticoagulation to prevent stroke). However, current AF screening approaches using a guideline age-based threshold of 65 years have shown limited yield. AF screening informed by AF risk models, including emerging artificial intelligence (AI)-based methods, may improve AF screening efficiency. Research Question: In a large AF screening trial, we sought to assess whether the effect of AF screening was higher among individuals with elevated AF risk. Methods: VITAL-AF was a cluster-randomized trial of patients aged 65 years treated at one of 16 primary care practices affiliated with Massachusetts General Hospital. Patients randomized to a screening practice underwent screening with single-lead ECG. Among individuals in VITAL-AF with 1 12-lead ECG within 3 years prior to enrollment, we estimated AF risk using three validated models derived independent of VITAL-AF: a) the Cohorts of Heart and Aging Research in Genomic Epidemiology-AF (CHARGE-AF) clinical score, b) an AI-based model utilizing 12-lead ECG alone (ECG-AI), and c) a model combining ECG-AI and CHARGE-AF (CH-AI). Discrimination of 2-year incident AF was quantified using the area under the receiver operating characteristic curve (AUROC) and average precision (AP). AF screening effect was defined as the difference in 2-year incident AF diagnosis (%) in screening versus control in the screened population across deciles of AF risk. Results: Of 30,630 VITAL-AF participants without prevalent AF, we analyzed 16,937 with available pre-trial ECG and clinical data. Each score discriminated 2-year AF risk (AUROC CHARGE-AF 0.700 [95%CI 0.654-0.739]; ECG-AI 0.780 [0.747-0.810]; CH-AI 0.781 [0.740-0.814]) (AP 0.0935 [0.0818-0.109]; 0.129 [0.111-0.154]; 0.131 [0.115-0.153]) ( Figure 1 ). An AF screening effect was observed in the top decile of CH-AI (2-year AF diagnosis rate 15.6% [13.1-19.4] in screening vs 11.9% [9.9-15.6] in control; difference 3.7% [0.3-7.1]) ( Figure 2 ). The AF screening effect was largest in the top decile of all three scores, but was numerically highest with CH-AI ( Figure 3 ). Conclusions: In VITAL-AF, the yield of AF screening appeared larger among individuals at high AF risk, particularly using a model combining clinical factors and AI-based ECG analysis. Future trials should assess whether risk-informed AF screening improves outcomes.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4362750
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4362750: Electrocardiogram-Based Artificial Intelligence to Improve the Efficiency of Atrial Fibrillation Screening: A VITAL-AF Trial Analysis

Daniel E. Singer, Leila H. Borowsky, Sachin J. Shah, Shaan Khurshid et al.
Circulation
ECG Monitoring and Analysis
article

Abstract 4362750: Electrocardiogram-Based Artificial Intelligence to Improve the Efficiency of Atrial Fibrillation Screening: A VITAL-AF Trial Analysis

Daniel E. Singer, Leila H. Borowsky, Sachin J. Shah, Shaan Khurshid, Steven A. Lubitz, Sam Friedman, Steven J. Atlas, Patrick T. Ellinor, Mahnaz Maddah, Yu Hao Chang, Natasha Vedage
article en

Abstract

Background: Atrial fibrillation (AF) is common and highly morbid. AF screening may detect AF earlier and facilitate preventive measures (e.g., anticoagulation to prevent stroke). However, current AF screening approaches using a guideline age-based threshold of 65 years have shown limited yield. AF screening informed by AF risk models, including emerging artificial intelligence (AI)-based methods, may improve AF screening efficiency. Research Question: In a large AF screening trial, we sought to assess whether the effect of AF screening was higher among individuals with elevated AF risk. Methods: VITAL-AF was a cluster-randomized trial of patients aged 65 years treated at one of 16 primary care practices affiliated with Massachusetts General Hospital. Patients randomized to a screening practice underwent screening with single-lead ECG. Among individuals in VITAL-AF with 1 12-lead ECG within 3 years prior to enrollment, we estimated AF risk using three validated models derived independent of VITAL-AF: a) the Cohorts of Heart and Aging Research in Genomic Epidemiology-AF (CHARGE-AF) clinical score, b) an AI-based model utilizing 12-lead ECG alone (ECG-AI), and c) a model combining ECG-AI and CHARGE-AF (CH-AI). Discrimination of 2-year incident AF was quantified using the area under the receiver operating characteristic curve (AUROC) and average precision (AP). AF screening effect was defined as the difference in 2-year incident AF diagnosis (%) in screening versus control in the screened population across deciles of AF risk. Results: Of 30,630 VITAL-AF participants without prevalent AF, we analyzed 16,937 with available pre-trial ECG and clinical data. Each score discriminated 2-year AF risk (AUROC CHARGE-AF 0.700 [95%CI 0.654-0.739]; ECG-AI 0.780 [0.747-0.810]; CH-AI 0.781 [0.740-0.814]) (AP 0.0935 [0.0818-0.109]; 0.129 [0.111-0.154]; 0.131 [0.115-0.153]) ( Figure 1 ). An AF screening effect was observed in the top decile of CH-AI (2-year AF diagnosis rate 15.6% [13.1-19.4] in screening vs 11.9% [9.9-15.6] in control; difference 3.7% [0.3-7.1]) ( Figure 2 ). The AF screening effect was largest in the top decile of all three scores, but was numerically highest with CH-AI ( Figure 3 ). Conclusions: In VITAL-AF, the yield of AF screening appeared larger among individuals at high AF risk, particularly using a model combining clinical factors and AI-based ECG analysis. Future trials should assess whether risk-informed AF screening improves outcomes.

CirculationVol. 152(Suppl_3)
Broad Institute (US), Newton Wellesley Hospital (US), Massachusetts General Hospital (US)
Openalex Percentile: Top 51%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.