Abstract 4373460: Clinical Effectiveness of Cerebral Embolic Protection (CEP) Devices During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

Introduction: Patients undergoing Transcatheter Aortic Valve Replacement/Implantation (TAVR/TAVI) are at risk of periprocedural cerebrovascular events. Cerebral Embolic Protection (CEP) devices have been developed to reduce the incidence of stroke and improve short-term outcomes in this population. This meta-analysis aimed to evaluate the safety and efficacy of CEP devices in patients undergoing TAVR/TAVI. Methods: A comprehensive literature search was conducted using PubMed, Cochrane Library, and ClinicalTrials.gov to identify relevant randomized controlled trials using keywords like “Transcatheter aortic valve replacement” or “Transcatheter aortic valve implantation” and “Cerebral Embolic Protection device”. After screening and eligibility assessment, 6 articles were included from an initial pool of 157 records. Meta-analysis was performed using RevMan 5.4 software. Quality assessment was performed using the Cochrane Risk of Bias tool. Results: Final analysis included 11,600 patients to investigate the relative effect of CEP devices versus no protection on different efficacy and safety outcomes in patients undergoing TAVR/TAVI. The pooled analysis demonstrated a non-significant reduction in the risk of stroke within 30 days in the CEP group compared to the control group (RR=0.81; 95% CI 0.61 to 1.07; p=0.14, I2 =14%). The use of CEP was not associated with a significant difference in all-cause mortality (RR=0.89; 95% CI 0.50 to 1.58; p=0.68, I2=18%), disabling stroke (RR=0.53; 95% CI 0.26 to 1.07; p=0.08, I2=44%) and non-disabling stroke (RR=0.92; 95% CI 0.61 to 1.39; p=0.69, I2=0%) within 30 days. Safety outcomes showed no significant differences between CEP and control groups in terms of major vascular complications (RR=0.98; 95% CI 054 to 1.77; p=0.95, I2 =50%), major or life-threatening bleeding (RR=0.67; 95% CI 0.26 to 1.78; p=0.43, I2 =64%), and acute kidney injury (RR=1.16; 95% CI 0.92 to 1.47; p=0.20, I2=0%). Discussion: CEP devices may reduce the risk of disabling stroke in patients undergoing TAVR/TAVI; however, the reduction did not reach statistical significance. Additionally, there was no significant benefit observed in all-cause mortality or other efficacy and safety outcomes. These findings highlight the need for larger, high-quality trials to better clarify the clinical value of CEP devices in this setting.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4373460
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4373460: Clinical Effectiveness of Cerebral Embolic Protection (CEP) Devices During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

Mohamed S. Hassaan, Haji Abdul Rehman Akhter, Dhiran Sivasubramanian, Momina Khalid et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4373460: Clinical Effectiveness of Cerebral Embolic Protection (CEP) Devices During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis

Mohamed S. Hassaan, Haji Abdul Rehman Akhter, Dhiran Sivasubramanian, Momina Khalid, Kevin Italiya
article en

Abstract

Introduction: Patients undergoing Transcatheter Aortic Valve Replacement/Implantation (TAVR/TAVI) are at risk of periprocedural cerebrovascular events. Cerebral Embolic Protection (CEP) devices have been developed to reduce the incidence of stroke and improve short-term outcomes in this population. This meta-analysis aimed to evaluate the safety and efficacy of CEP devices in patients undergoing TAVR/TAVI. Methods: A comprehensive literature search was conducted using PubMed, Cochrane Library, and ClinicalTrials.gov to identify relevant randomized controlled trials using keywords like “Transcatheter aortic valve replacement” or “Transcatheter aortic valve implantation” and “Cerebral Embolic Protection device”. After screening and eligibility assessment, 6 articles were included from an initial pool of 157 records. Meta-analysis was performed using RevMan 5.4 software. Quality assessment was performed using the Cochrane Risk of Bias tool. Results: Final analysis included 11,600 patients to investigate the relative effect of CEP devices versus no protection on different efficacy and safety outcomes in patients undergoing TAVR/TAVI. The pooled analysis demonstrated a non-significant reduction in the risk of stroke within 30 days in the CEP group compared to the control group (RR=0.81; 95% CI 0.61 to 1.07; p=0.14, I2 =14%). The use of CEP was not associated with a significant difference in all-cause mortality (RR=0.89; 95% CI 0.50 to 1.58; p=0.68, I2=18%), disabling stroke (RR=0.53; 95% CI 0.26 to 1.07; p=0.08, I2=44%) and non-disabling stroke (RR=0.92; 95% CI 0.61 to 1.39; p=0.69, I2=0%) within 30 days. Safety outcomes showed no significant differences between CEP and control groups in terms of major vascular complications (RR=0.98; 95% CI 054 to 1.77; p=0.95, I2 =50%), major or life-threatening bleeding (RR=0.67; 95% CI 0.26 to 1.78; p=0.43, I2 =64%), and acute kidney injury (RR=1.16; 95% CI 0.92 to 1.47; p=0.20, I2=0%). Discussion: CEP devices may reduce the risk of disabling stroke in patients undergoing TAVR/TAVI; however, the reduction did not reach statistical significance. Additionally, there was no significant benefit observed in all-cause mortality or other efficacy and safety outcomes. These findings highlight the need for larger, high-quality trials to better clarify the clinical value of CEP devices in this setting.

CirculationVol. 152(Suppl_3)
Children's Hospital of Philadelphia (US), Nishtar Medical College and Hospital (PK), Jinnah Sindh Medical University (PK), Sardar Vallabhbhai National Institute of Technology Surat (IN), Central Cotton Research Institute (PK)
Openalex Percentile: Top 51%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.