Abstract 4365473: Cerebral embolic protection in Transcather Aortic Valve Replacement: An updated meta-analysis of 11692 patients

Background: We conducted an updated meta-analysis of the routine use of cerebral embolic protection (CEP) devices in Transcathter Aortic Valve Replacement (TAVR). This analysis follows the recent BHF PROTECTED TAVI trial which is the largest randomized controlled trial to date. Methods: Electronic databases were searched through April 2025 for eligible randomized controlled trials (RCTs). The primary outcome was overall incidence of stroke, disabling stroke and non-disabling stroke all reported at 2-5 days and 30 days were primary outcomes for our analyses. Results: 8 RCTs with a total of 11,692 patients were included. No statistically significant difference was found between CEP group and the control group in overall stroke incidence at 2-5 days and 30 days as the following (RR=0.95, 95%CI: [0.75,1.19], p=0.64) and (RR=0.93, 95%CI: [0.57,1.53], p=0.79). Similarly, the pooled analysis revealed no statistically significant difference between the two groups in terms of disabling stroke at 2-5 days (RR=0.70, 95%CI: [0.41,1.18], p=0.18), and at 30 days (RR=1.18, 95%CI: [0.36,3.87], p=0.78). CEP group and control group didn’t show statistically significant difference in non- disabling stroke at 2-5 days and 30 days as the results showed: (RR=1.17, 95%CI: [0.84,1.63], p=0.36) and (RR=0.86, 95%CI: [0.49,1.51], P=0.61) respectively. Conclusion: Our meta-analysis found no statistically significant evidence that cerebral embolic protection (CEP) devices reduce the incidence of stroke—disabling or non-disabling in the 2-5 days following TAVR or after 30 days. Major bleeding, major vascular complication and AKI showed no statistically significant results indicating a neutral safety profile.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4365473
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4365473: Cerebral embolic protection in Transcather Aortic Valve Replacement: An updated meta-analysis of 11692 patients

Ahmed Ali, Rana Rashwan, Ahmed Farid Gadelmawla, Mohamed M. El Nady et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4365473: Cerebral embolic protection in Transcather Aortic Valve Replacement: An updated meta-analysis of 11692 patients

Ahmed Ali, Rana Rashwan, Ahmed Farid Gadelmawla, Mohamed M. El Nady, Mohamed Fawzi Hemida, Mohamed Khalafallah, Ramez Barsoom, Raneem Afify, Amal Al‐Omari, Bas Kietselaer, Ahmed Mohamed, Aya Elalfy, Imad Samman Tahhan, Zeyad Kholeif, Hamza Elkasaby, Mohab Elnashar
article en

Abstract

Background: We conducted an updated meta-analysis of the routine use of cerebral embolic protection (CEP) devices in Transcathter Aortic Valve Replacement (TAVR). This analysis follows the recent BHF PROTECTED TAVI trial which is the largest randomized controlled trial to date. Methods: Electronic databases were searched through April 2025 for eligible randomized controlled trials (RCTs). The primary outcome was overall incidence of stroke, disabling stroke and non-disabling stroke all reported at 2-5 days and 30 days were primary outcomes for our analyses. Results: 8 RCTs with a total of 11,692 patients were included. No statistically significant difference was found between CEP group and the control group in overall stroke incidence at 2-5 days and 30 days as the following (RR=0.95, 95%CI: [0.75,1.19], p=0.64) and (RR=0.93, 95%CI: [0.57,1.53], p=0.79). Similarly, the pooled analysis revealed no statistically significant difference between the two groups in terms of disabling stroke at 2-5 days (RR=0.70, 95%CI: [0.41,1.18], p=0.18), and at 30 days (RR=1.18, 95%CI: [0.36,3.87], p=0.78). CEP group and control group didn’t show statistically significant difference in non- disabling stroke at 2-5 days and 30 days as the results showed: (RR=1.17, 95%CI: [0.84,1.63], p=0.36) and (RR=0.86, 95%CI: [0.49,1.51], P=0.61) respectively. Conclusion: Our meta-analysis found no statistically significant evidence that cerebral embolic protection (CEP) devices reduce the incidence of stroke—disabling or non-disabling in the 2-5 days following TAVR or after 30 days. Major bleeding, major vascular complication and AKI showed no statistically significant results indicating a neutral safety profile.

CirculationVol. 152(Suppl_3)
Kafrelsheikh University (EG), Mayo Clinic (US), Cairo University (EG), Medical University of South Carolina (US), Tanta University (EG), University of Arkansas Medical Center (US), Jacksonville College (US), WinnMed (US), Mayo Clinic in Arizona (US), Baptist Medical Center Jacksonville (US), Mayo Clinic in Florida (US), Menoufia University (EG), Alexandria University (EG), Yarmouk University (JO)
Openalex Percentile: Top 51%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.