Abstract 4373072: Evaluating the Outcomes and Complications of Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy

Background: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death in patients with hypertrophic cardiomyopathy (HCM). However, ICD implantation is associated with risks, including inappropriate therapy, lead failure, and pocket bleeding, which may impact patient outcomes. Research Question: What are the incidence rates of complications and outcomes associated with ICD implantation in HCM patients? Objective: To quantify the annualized incidence rates of ICD-related complications and clinical outcomes, including appropriate interventions, inappropriate therapy, mortality, and device-related adverse events, in HCM patients. Methods: This PRISMA-compliant systematic review and meta-analysis included 30 studies from PubMed and ScienceDirect, reporting outcomes and complications post-ICD implantation in HCM patients. Data on ICD interventions, mortality, and device-related complications were extracted. Pooled annualized incidence rates were calculated using random- and fixed-effects models. Results: The meta-analysis included 5,618 HCM patients with ICDs. The annualized rate of appropriate ICD interventions was 4.00%. All-cause mortality was 1.30% per year, with cardiac and non-cardiac mortality each at 0.60% per year. Inappropriate therapy occurred at 3.80% per year. Device-related complications included lead malfunction (1.40%), lead displacement (1.10%), infection (0.70%), pocket bleeding (0.60%), cardiac tamponade (0.20%), deep vein thrombosis (0.30%), and pneumothorax (0.10%) per year. Heart transplant occurred at 0.80% per year. Conclusions: ICDs in HCM patients demonstrate a favorable annualized appropriate intervention rate of 4.00% and low mortality rates. However, moderate rates of inappropriate therapy and device-related complications highlight the need for careful patient selection to optimize the risk-benefit profile. Further studies are needed to refine ICD indications and reduce complications in HCM populations.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4373072
Primary Topic
Cardiomyopathy and Myosin Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4373072: Evaluating the Outcomes and Complications of Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy

Sanaa A. Ali, Muhammad Muneeb Khawar, Mobeen Z. Haider, Umair Bajwa et al.
Circulation
Cardiomyopathy and Myosin Studies
article

Abstract 4373072: Evaluating the Outcomes and Complications of Implantable Cardioverter Defibrillator Therapy in Hypertrophic Cardiomyopathy

Sanaa A. Ali, Muhammad Muneeb Khawar, Mobeen Z. Haider, Umair Bajwa, Muneeb Khawar, Mirza Muhammad Hadeed Khawar, Syed Faqeer Hussain Bokhari, Ali Sohail, Danyal Bakht, Muhammad Aamir, M S Cheema, Masud Shaukat, Aliya Shawaiz
article en

Abstract

Background: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death in patients with hypertrophic cardiomyopathy (HCM). However, ICD implantation is associated with risks, including inappropriate therapy, lead failure, and pocket bleeding, which may impact patient outcomes. Research Question: What are the incidence rates of complications and outcomes associated with ICD implantation in HCM patients? Objective: To quantify the annualized incidence rates of ICD-related complications and clinical outcomes, including appropriate interventions, inappropriate therapy, mortality, and device-related adverse events, in HCM patients. Methods: This PRISMA-compliant systematic review and meta-analysis included 30 studies from PubMed and ScienceDirect, reporting outcomes and complications post-ICD implantation in HCM patients. Data on ICD interventions, mortality, and device-related complications were extracted. Pooled annualized incidence rates were calculated using random- and fixed-effects models. Results: The meta-analysis included 5,618 HCM patients with ICDs. The annualized rate of appropriate ICD interventions was 4.00%. All-cause mortality was 1.30% per year, with cardiac and non-cardiac mortality each at 0.60% per year. Inappropriate therapy occurred at 3.80% per year. Device-related complications included lead malfunction (1.40%), lead displacement (1.10%), infection (0.70%), pocket bleeding (0.60%), cardiac tamponade (0.20%), deep vein thrombosis (0.30%), and pneumothorax (0.10%) per year. Heart transplant occurred at 0.80% per year. Conclusions: ICDs in HCM patients demonstrate a favorable annualized appropriate intervention rate of 4.00% and low mortality rates. However, moderate rates of inappropriate therapy and device-related complications highlight the need for careful patient selection to optimize the risk-benefit profile. Further studies are needed to refine ICD indications and reduce complications in HCM populations.

CirculationVol. 152(Suppl_3)
West Virginia University (US), Services Institute of Medical Sciences (PK), Lehigh Valley Hospital-Pocono (US), King Edward Medical University (PK), Rashid Latif Medical College (PK), Lehigh Valley Health Network (US), Mayo Hospital (PK)
Openalex Percentile: Top 51%
Cardiomyopathy and Myosin Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.