Abstract 4368556: Mechanical Circulatory Support Device Related Complications in Contemporary North American Cardiac Intensive Care Units

Background: The use of temporary mechanical circulatory support (tMCS) devices in cardiogenic shock has sharply risen; however, there are limited data depicting the current rates of device related complications and associated downstream clinical ramifications. Methods: The Critical Care Cardiology Trials Network is an international multicenter research network of advanced cardiac intensive care units (CICUs). Between 2017-2024 participating CICUs captured all consecutive admissions with cardiogenic shock during annual minimum 2-month collection periods. This analysis focused on cases managed with non-ECMO tMCS. We conducted Wilcoxon rank-sum tests for continuous variables, chi-squared test for categorical variables, and a multi-variable linear mixed-effect regression model. Results: Among 2,015 admissions with cardiogenic shock and tMCS, 103 (5.1%) developed an MCS-related complication with substantial variation across device types (2.8% to 10.9%, Fig A ). Limb ischemia (28.9%) and access site bleeding (22.9%) were the most common tMCS-related complications. Admissions with a tMCS related complication were slightly younger (61 v. 63 years) and more likely female (34% v. 27%). Cases with tMCS-related complications had higher shock severity reflected by more SCAI D shock (43.7% versus 35.1%) and number of vasoactive medications (3 v. 2). Admissions with an MCS complication had higher rates of mechanical ventilation (68.9% v. 59.1%) and renal replacement therapy (33.0% v. 17.6%) with longer ICU length of stay (9.2 v. 6.6 days). In-hospital mortality was higher among cases with complications (46.6% v. 31.6%; Fig B ); complications were associated with a higher mortality even after adjustment (OR 1.63; 95% CI: 1.00 – 2.67; p = 0.05). Conclusions: The rates of MCS related complications vary notably by access site and specific modality; complications were associated with longer ICU stays and high mortality rates.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4368556
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4368556: Mechanical Circulatory Support Device Related Complications in Contemporary North American Cardiac Intensive Care Units

Jeong‐Gun Park, Erin A. Bohula, Ajar Kochar, Siddharth M. Patel et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4368556: Mechanical Circulatory Support Device Related Complications in Contemporary North American Cardiac Intensive Care Units

Jeong‐Gun Park, Erin A. Bohula, Ajar Kochar, Siddharth M. Patel, David A. Morrow, David Van Den Berg
article en

Abstract

Background: The use of temporary mechanical circulatory support (tMCS) devices in cardiogenic shock has sharply risen; however, there are limited data depicting the current rates of device related complications and associated downstream clinical ramifications. Methods: The Critical Care Cardiology Trials Network is an international multicenter research network of advanced cardiac intensive care units (CICUs). Between 2017-2024 participating CICUs captured all consecutive admissions with cardiogenic shock during annual minimum 2-month collection periods. This analysis focused on cases managed with non-ECMO tMCS. We conducted Wilcoxon rank-sum tests for continuous variables, chi-squared test for categorical variables, and a multi-variable linear mixed-effect regression model. Results: Among 2,015 admissions with cardiogenic shock and tMCS, 103 (5.1%) developed an MCS-related complication with substantial variation across device types (2.8% to 10.9%, Fig A ). Limb ischemia (28.9%) and access site bleeding (22.9%) were the most common tMCS-related complications. Admissions with a tMCS related complication were slightly younger (61 v. 63 years) and more likely female (34% v. 27%). Cases with tMCS-related complications had higher shock severity reflected by more SCAI D shock (43.7% versus 35.1%) and number of vasoactive medications (3 v. 2). Admissions with an MCS complication had higher rates of mechanical ventilation (68.9% v. 59.1%) and renal replacement therapy (33.0% v. 17.6%) with longer ICU length of stay (9.2 v. 6.6 days). In-hospital mortality was higher among cases with complications (46.6% v. 31.6%; Fig B ); complications were associated with a higher mortality even after adjustment (OR 1.63; 95% CI: 1.00 – 2.67; p = 0.05). Conclusions: The rates of MCS related complications vary notably by access site and specific modality; complications were associated with longer ICU stays and high mortality rates.

CirculationVol. 152(Suppl_3)
Brigham and Women's Hospital (US), Chestnut Hill College (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.