Abstract 4365553: Death-Associated Malfunctions in Boston Scientific ICDs: Insights from Postmarket Device Event Reports (2022–2024)

Background: Implantable cardioverter-defibrillators (ICDs) reduce mortality in patients at risk for sudden cardiac death, but postmarket surveillance is essential for detecting rare device-related safety concerns. We analyzed death-associated adverse events involving Boston Scientific ICDs to identify recurrent patterns of device malfunction. Methods: We conducted a retrospective analysis of publicly available adverse event reports submitted to the U.S. Food and Drug Administration’s Manufacturer and User Facility Device Experience (MAUDE) database between January 2022 and December 2024. We included all reports explicitly involving Boston Scientific ICDs that the manufacturer or reporter classified as resulting in patient death. Data were reviewed for patient demographics, device type and model, and categorized failure modes based on structured fields and a manual review of narrative descriptions. Results: A total of 67 death-related events were identified. The most commonly involved models included the Emblem MRI S-ICD (n=14), Reliance 4-Front (n=12), and Autogen (n=5). Device types included dual chamber (30%), subcutaneous (28%), single chamber (28%), and unspecified (14%). Subcutaneous ICDs, designed to reduce transvenous complications, accounted for over a quarter of reported deaths. The most frequent device-related issues were rhythm conversion failure (28%), device integrity problems (24%), battery power failure (9%), and sensing signal abnormalities (7%). The median patient age was 68 years (range: 36–85); 43% were male, 37% female, and 20% unspecified. Narrative review revealed failure clusters involving delayed therapy, abrupt battery depletion, and electrical signal misdetection. In one case, a patient with known battery warning signs experienced sudden asystole and died days later. Another report detailed failure to detect ventricular fibrillation in a patient implanted with an S-ICD. Conclusion: Deaths associated with Boston Scientific ICDs reveal recurring patterns of electrical and mechanical failure, particularly rhythm conversion failure and device integrity issues. Subcutaneous ICDs appear disproportionately represented. These findings underscore the ongoing importance of real-world surveillance in identifying potential device vulnerabilities and informing both engineering improvements and clinical decision-making.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4365553
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4365553: Death-Associated Malfunctions in Boston Scientific ICDs: Insights from Postmarket Device Event Reports (2022–2024)

Magdy Attia
Circulation
Cardiac pacing and defibrillation studies
article

Abstract 4365553: Death-Associated Malfunctions in Boston Scientific ICDs: Insights from Postmarket Device Event Reports (2022–2024)

Magdy Attia
article en

Abstract

Background: Implantable cardioverter-defibrillators (ICDs) reduce mortality in patients at risk for sudden cardiac death, but postmarket surveillance is essential for detecting rare device-related safety concerns. We analyzed death-associated adverse events involving Boston Scientific ICDs to identify recurrent patterns of device malfunction. Methods: We conducted a retrospective analysis of publicly available adverse event reports submitted to the U.S. Food and Drug Administration’s Manufacturer and User Facility Device Experience (MAUDE) database between January 2022 and December 2024. We included all reports explicitly involving Boston Scientific ICDs that the manufacturer or reporter classified as resulting in patient death. Data were reviewed for patient demographics, device type and model, and categorized failure modes based on structured fields and a manual review of narrative descriptions. Results: A total of 67 death-related events were identified. The most commonly involved models included the Emblem MRI S-ICD (n=14), Reliance 4-Front (n=12), and Autogen (n=5). Device types included dual chamber (30%), subcutaneous (28%), single chamber (28%), and unspecified (14%). Subcutaneous ICDs, designed to reduce transvenous complications, accounted for over a quarter of reported deaths. The most frequent device-related issues were rhythm conversion failure (28%), device integrity problems (24%), battery power failure (9%), and sensing signal abnormalities (7%). The median patient age was 68 years (range: 36–85); 43% were male, 37% female, and 20% unspecified. Narrative review revealed failure clusters involving delayed therapy, abrupt battery depletion, and electrical signal misdetection. In one case, a patient with known battery warning signs experienced sudden asystole and died days later. Another report detailed failure to detect ventricular fibrillation in a patient implanted with an S-ICD. Conclusion: Deaths associated with Boston Scientific ICDs reveal recurring patterns of electrical and mechanical failure, particularly rhythm conversion failure and device integrity issues. Subcutaneous ICDs appear disproportionately represented. These findings underscore the ongoing importance of real-world surveillance in identifying potential device vulnerabilities and informing both engineering improvements and clinical decision-making.

CirculationVol. 152(Suppl_3)
University of California, Davis (US)
Openalex Percentile: Top 51%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.