Introduction/Background: Microaxial flow devices such as Impella RP provide a temporary therapeutic approach for managing acute RV failure. However, the use of parallel stiff wires (“buddy-wire” technique) for its placement has rarely been described, particularly in patients with complex anatomy and implanted cardiac devices. Case Presentation: A 70-year-old male with HFrEF with CRT-D and HeartMate3 LVAD, RV failure status-post RVAD placement and recent explantation, presented after multiple ICD shocks. He initially presented in ventricular tachycardia (VT) at 200 bpm (Figure 1). Despite 3 attempts of DCCV and amiodarone infusion, he remained in VT. He was intubated to reduce sympathetic tone. A low flow alarm from the LVAD was noted. TTE showed a severely dilated RV with evidence of pressure overload (Figure 2). The patient also required rapid escalation of vasopressors. He was taken emergently for RHC and possible MCS placement. The PA catheter was inserted and advanced to the wedge position in the PA via the right femoral vein. The calculated PAPi was 0.63, the CPO was 0.35, and the wedge pressure was 23 mmHg. A decision was made to place an Impella RP for biventricular shock in the context of a pre-existing LVAD. However, delivering the Impella RP across the tricuspid valve was challenging, as the guidewire became entangled under the ICD lead in a dilated RV. The previously placed guidewire was repositioned up, over, and away from the ICD lead (Figure 3A). We utilized the buddy-catheter technique, akin to the buddy-wire technique, to facilitate passage of Impella RP across the pulmonic valve with the assistance of the previously placed PA catheter (Figure 3A). The Impella RP was then successfully placed, and the PA catheter was left in place for hemodynamic monitoring (Figure 3B,C). Post-impella implantation improved the hemodynamics to a PAPi of 1.2, MAP of 70 mmHg, and a reduction in vasopressor requirements. The patient was ultimately transferred to a heart transplant center for further management. Discussion/Conclusion: Utilizing the “buddy-wire” technique for placement of an Impella RP is a viable method in patients with complex right-heart anatomy who may present with concurrent cardiogenic shock. The need to deliver the Impella RP across the tricuspid valve posed a risk of dislodging the RV CRT-D lead. Nonetheless, implementing the “buddy-wire” technique ensured the easier passage of the Impella, bypassing anatomical tortuosity.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4365916
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4365916: The “Buddy-Wire” Technique: Navigating Complex Anatomy to Guide Placement of an RP Impella

KaChon Lei, Dalia Hawwass, Michael DiCaro, Vasiliki Tasouli-Drakou et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4365916: The “Buddy-Wire” Technique: Navigating Complex Anatomy to Guide Placement of an RP Impella

KaChon Lei, Dalia Hawwass, Michael DiCaro, Vasiliki Tasouli-Drakou, Chowdhury Ahsan, Brianna Yee
article en

Abstract

Introduction/Background: Microaxial flow devices such as Impella RP provide a temporary therapeutic approach for managing acute RV failure. However, the use of parallel stiff wires (“buddy-wire” technique) for its placement has rarely been described, particularly in patients with complex anatomy and implanted cardiac devices. Case Presentation: A 70-year-old male with HFrEF with CRT-D and HeartMate3 LVAD, RV failure status-post RVAD placement and recent explantation, presented after multiple ICD shocks. He initially presented in ventricular tachycardia (VT) at 200 bpm (Figure 1). Despite 3 attempts of DCCV and amiodarone infusion, he remained in VT. He was intubated to reduce sympathetic tone. A low flow alarm from the LVAD was noted. TTE showed a severely dilated RV with evidence of pressure overload (Figure 2). The patient also required rapid escalation of vasopressors. He was taken emergently for RHC and possible MCS placement. The PA catheter was inserted and advanced to the wedge position in the PA via the right femoral vein. The calculated PAPi was 0.63, the CPO was 0.35, and the wedge pressure was 23 mmHg. A decision was made to place an Impella RP for biventricular shock in the context of a pre-existing LVAD. However, delivering the Impella RP across the tricuspid valve was challenging, as the guidewire became entangled under the ICD lead in a dilated RV. The previously placed guidewire was repositioned up, over, and away from the ICD lead (Figure 3A). We utilized the buddy-catheter technique, akin to the buddy-wire technique, to facilitate passage of Impella RP across the pulmonic valve with the assistance of the previously placed PA catheter (Figure 3A). The Impella RP was then successfully placed, and the PA catheter was left in place for hemodynamic monitoring (Figure 3B,C). Post-impella implantation improved the hemodynamics to a PAPi of 1.2, MAP of 70 mmHg, and a reduction in vasopressor requirements. The patient was ultimately transferred to a heart transplant center for further management. Discussion/Conclusion: Utilizing the “buddy-wire” technique for placement of an Impella RP is a viable method in patients with complex right-heart anatomy who may present with concurrent cardiogenic shock. The need to deliver the Impella RP across the tricuspid valve posed a risk of dislodging the RV CRT-D lead. Nonetheless, implementing the “buddy-wire” technique ensured the easier passage of the Impella, bypassing anatomical tortuosity.

CirculationVol. 152(Suppl_3)
University of Nevada, Las Vegas (US), University Medical Center of Southern Nevada (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.