Abstract 4365901: Predictive Value of Patent False Lumen Extent for Postoperative Hypoxia in Acute Type A Aortic Dissection

Background: Acute type A aortic dissection (AAAD) is frequently complicated by severe respiratory failure due to acute lung injury, contributing to postoperative mortality. This study investigated the association between the extent of the patent false lumen and postoperative hypoxia in patients with AAAD. Methods: We retrospectively analyzed 143 patients with AAAD who had a patent false lumen and underwent surgical repair within 24 hours of diagnosis. Severe hypoxia was defined as PaO 2 /FiO 2 (PF) ratio <200 during postoperative endotracheal intubation. The volume of the patent false lumen was calculated as the product of CT slice thickness and the summed area of the false lumen across all axial slices. Additionally, the length of the aorta with a patent false lumen was measured using centerline analysis (Fig 1). Results: Severe hypoxia occurred in 66% of patients. Compared to those without oxygenation impairment, patients with hypoxia had significantly longer ICU stays, prolonged mechanical ventilation, and lower minimum PF ratios (all p<0.05). The hypoxia group also showed significantly greater false lumen length and volume (p<0.01). In contrast, no significant differences were found in smoking history, surgical procedure, or operative time between the two groups. Receiver operating characteristic (ROC) curve analysis demonstrated that both the length and volume of the patent false lumen had modest predictive ability for postoperative hypoxia, with areas under the curve (AUC) of 0.68 and 0.70, respectively. The optimal cut-off value for length was 439mm (sensitivity 66%, specificity 65%), and for volume, 185 cm 3 (sensitivity 60%, specificity 59%). Conclusions: The extent of the patent false lumen was identified as a risk factor for postoperative hypoxia in AAAD. Greater intimal disruption was associated with postoperative respiratory complications. Preoperative assessment of false lumen morphology may assist in identifying high-risk patients and guiding appropriate respiratory management.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4365901
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4365901: Predictive Value of Patent False Lumen Extent for Postoperative Hypoxia in Acute Type A Aortic Dissection

Yusuke Samejima, Hitoshi Anzai, Yuika Kameda, Naohiko Nemoto
Circulation
Aortic Disease and Treatment Approaches
article

Abstract 4365901: Predictive Value of Patent False Lumen Extent for Postoperative Hypoxia in Acute Type A Aortic Dissection

Yusuke Samejima, Hitoshi Anzai, Yuika Kameda, Naohiko Nemoto
article en

Abstract

Background: Acute type A aortic dissection (AAAD) is frequently complicated by severe respiratory failure due to acute lung injury, contributing to postoperative mortality. This study investigated the association between the extent of the patent false lumen and postoperative hypoxia in patients with AAAD. Methods: We retrospectively analyzed 143 patients with AAAD who had a patent false lumen and underwent surgical repair within 24 hours of diagnosis. Severe hypoxia was defined as PaO 2 /FiO 2 (PF) ratio <200 during postoperative endotracheal intubation. The volume of the patent false lumen was calculated as the product of CT slice thickness and the summed area of the false lumen across all axial slices. Additionally, the length of the aorta with a patent false lumen was measured using centerline analysis (Fig 1). Results: Severe hypoxia occurred in 66% of patients. Compared to those without oxygenation impairment, patients with hypoxia had significantly longer ICU stays, prolonged mechanical ventilation, and lower minimum PF ratios (all p<0.05). The hypoxia group also showed significantly greater false lumen length and volume (p<0.01). In contrast, no significant differences were found in smoking history, surgical procedure, or operative time between the two groups. Receiver operating characteristic (ROC) curve analysis demonstrated that both the length and volume of the patent false lumen had modest predictive ability for postoperative hypoxia, with areas under the curve (AUC) of 0.68 and 0.70, respectively. The optimal cut-off value for length was 439mm (sensitivity 66%, specificity 65%), and for volume, 185 cm 3 (sensitivity 60%, specificity 59%). Conclusions: The extent of the patent false lumen was identified as a risk factor for postoperative hypoxia in AAAD. Greater intimal disruption was associated with postoperative respiratory complications. Preoperative assessment of false lumen morphology may assist in identifying high-risk patients and guiding appropriate respiratory management.

CirculationVol. 152(Suppl_3)
Fuji Heavy Industries Health Insurance Society Ota Memorial Hospital (JP)
Openalex Percentile: Top 54%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.