Abstract 4363348: Multi-View Deep Learning for Automated Quantification of Aortic Stenosis

Background: Accurate assessment of aortic stenosis (AS) severity is critical to reduce associated morbidity and mortality. Current evaluation relies on expert interpretation of B-mode and Doppler echocardiography across multiple views. This study aimed to develop and validate a deep learning model for automated AS severity assessment using multi-view B-mode and color Doppler echocardiographic videos. Methods: We designed a two-stage framework for automated AS assessment. First, six video-based convolutional neural networks were trained to classify AS severity from distinct echocardiographic views: B-mode [parasternal long-axis (PLAX), parasternal short-axis (PSAX), apical three-chamber and five-chamber (AP)] and color Doppler [PLAX-color, PSAX-color, and AP-color]. Next, outputs from these models were integrated using a machine learning ensemble (HistGradientBoostingClassifier) to produce a study-level AS severity classification. Performance was assessed using area under the receiver operating characteristic curve (AUC) on held-out test set from Kaiser Permanente (KP) and Stanford Health Care (SHC). Results: The models were trained on 213,814 videos from 16,076 studies at KP, and evaluated on internal test data (KP; 23,492 videos from 1,789 studies) as well as external test data (SHC; 13,278 videos from 1,238 studies). The multi-view ensemble model demonstrated strong performance, achieving a macro-AUC of 0.891 (95% CI: 0.881–0.901; Figure 1) on the KP test dataset. Generalizability was confirmed on the external SHC cohort with an AUC of 0.929 (95% CI: 0.918–0.939; Figure 2). Conclusion: In this study, we applied a deep learning framework integrating multi-view echocardiographic videos to assess AS severity. The model demonstrated accurate, generalizable performance and highlights the potential of AI-powered decision support tools in echocardiographic evaluation of AS.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4363348
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4363348: Multi-View Deep Learning for Automated Quantification of Aortic Stenosis

Bryan D. He, Miloš Vukadinovic, Hirotaka Ieki, Yuki Sahashi et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4363348: Multi-View Deep Learning for Automated Quantification of Aortic Stenosis

Bryan D. He, Miloš Vukadinovic, Hirotaka Ieki, Yuki Sahashi, David Ouyang, Paul P. Cheng
article en

Abstract

Background: Accurate assessment of aortic stenosis (AS) severity is critical to reduce associated morbidity and mortality. Current evaluation relies on expert interpretation of B-mode and Doppler echocardiography across multiple views. This study aimed to develop and validate a deep learning model for automated AS severity assessment using multi-view B-mode and color Doppler echocardiographic videos. Methods: We designed a two-stage framework for automated AS assessment. First, six video-based convolutional neural networks were trained to classify AS severity from distinct echocardiographic views: B-mode [parasternal long-axis (PLAX), parasternal short-axis (PSAX), apical three-chamber and five-chamber (AP)] and color Doppler [PLAX-color, PSAX-color, and AP-color]. Next, outputs from these models were integrated using a machine learning ensemble (HistGradientBoostingClassifier) to produce a study-level AS severity classification. Performance was assessed using area under the receiver operating characteristic curve (AUC) on held-out test set from Kaiser Permanente (KP) and Stanford Health Care (SHC). Results: The models were trained on 213,814 videos from 16,076 studies at KP, and evaluated on internal test data (KP; 23,492 videos from 1,789 studies) as well as external test data (SHC; 13,278 videos from 1,238 studies). The multi-view ensemble model demonstrated strong performance, achieving a macro-AUC of 0.891 (95% CI: 0.881–0.901; Figure 1) on the KP test dataset. Generalizability was confirmed on the external SHC cohort with an AUC of 0.929 (95% CI: 0.918–0.939; Figure 2). Conclusion: In this study, we applied a deep learning framework integrating multi-view echocardiographic videos to assess AS severity. The model demonstrated accurate, generalizable performance and highlights the potential of AI-powered decision support tools in echocardiographic evaluation of AS.

CirculationVol. 152(Suppl_3)
Cedars-Sinai Medical Center (US), Kaiser Permanente (US), University of California, Los Angeles (US), Stanford University (US)
Openalex Percentile: Top 51%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.