Abstract 4365135: Concomitant Pulsed Field Ablation and Left Atrial Appendage Closure Using WATCHMAN FLX Pro: A Preclinical Evaluation of Procedural Compatibility and Tissue Response

Background: Pulsed field ablation is a novel non-thermal energy source for pulmonary vein isolation that offers potential procedural and safety advantages over thermal modalities. However, its acute anatomical effects and compatibility with same-session left atrial appendage closure remain insufficiently characterized. Objective: To evaluate the feasibility, safety, and anatomical response of combining PFA-based PVI with LAAC using the WATCHMAN FLX Pro device in a healthy canine model. Methods: Nine canines underwent PVI with either PFA (n=6) or radiofrequency ablation (RFA; n=3), followed by LAAC with the WATCHMAN FLX Pro in a single session. Procedural success, tissue remodeling, device compression, and peri-device leaks were assessed using serial transesophageal echocardiography and computed tomography over a 45-day period, with terminal pathological analysis. Results: All procedures were completed without complications, and LAAC met PASS criteria in all animals. TEE confirmed complete seal at implant and at 45 days in both groups. PFA was associated with greater post-ablation reduction in LAA diameters and significantly higher device compression (23±8% vs. 13±4% by TEE) despite smaller average device sizes. CT demonstrated greater early compression loss in the PFA group, with gradual recovery by Day 45. Two minor peri-device leaks (<5 mm) were identified on CT in the PFA group only. Ridge edema and anatomical remodeling were pronounced acutely in the PFA group but resolved by 45 days. No thrombus, embolic events, or device dislodgement occurred at any point during the study. Conclusion: In this preclinical study, the combination of PFA and LAAC using the WATCHMAN FLX Pro device was feasible and acutely safe. PFA was associated with greater acute anatomical remodeling compared to RFA, including more pronounced tissue edema and device compression. These changes resolved over time without compromising device seal or position. Small peri-device leaks (<5 mm) were observed on follow-up CT but not TEE imaging in the pulsed field ablation group only. Further studies are warranted to assess the long-term implications of PFA–associated remodeling and its potential impact on device performance.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4365135
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4365135: Concomitant Pulsed Field Ablation and Left Atrial Appendage Closure Using WATCHMAN FLX Pro: A Preclinical Evaluation of Procedural Compatibility and Tissue Response

Caroline Floreoto Baldo, Erin Hynes, Brad J. Mikaelian, Charbel Noujaim et al.
Circulation
Atrial Fibrillation Management and Outcomes
article

Abstract 4365135: Concomitant Pulsed Field Ablation and Left Atrial Appendage Closure Using WATCHMAN FLX Pro: A Preclinical Evaluation of Procedural Compatibility and Tissue Response

Caroline Floreoto Baldo, Erin Hynes, Brad J. Mikaelian, Charbel Noujaim, Walid I. Saliba, David De Lurgio, Andrea Natale, Austin Caldwell, Wael A. Jaber
article en

Abstract

Background: Pulsed field ablation is a novel non-thermal energy source for pulmonary vein isolation that offers potential procedural and safety advantages over thermal modalities. However, its acute anatomical effects and compatibility with same-session left atrial appendage closure remain insufficiently characterized. Objective: To evaluate the feasibility, safety, and anatomical response of combining PFA-based PVI with LAAC using the WATCHMAN FLX Pro device in a healthy canine model. Methods: Nine canines underwent PVI with either PFA (n=6) or radiofrequency ablation (RFA; n=3), followed by LAAC with the WATCHMAN FLX Pro in a single session. Procedural success, tissue remodeling, device compression, and peri-device leaks were assessed using serial transesophageal echocardiography and computed tomography over a 45-day period, with terminal pathological analysis. Results: All procedures were completed without complications, and LAAC met PASS criteria in all animals. TEE confirmed complete seal at implant and at 45 days in both groups. PFA was associated with greater post-ablation reduction in LAA diameters and significantly higher device compression (23±8% vs. 13±4% by TEE) despite smaller average device sizes. CT demonstrated greater early compression loss in the PFA group, with gradual recovery by Day 45. Two minor peri-device leaks (<5 mm) were identified on CT in the PFA group only. Ridge edema and anatomical remodeling were pronounced acutely in the PFA group but resolved by 45 days. No thrombus, embolic events, or device dislodgement occurred at any point during the study. Conclusion: In this preclinical study, the combination of PFA and LAAC using the WATCHMAN FLX Pro device was feasible and acutely safe. PFA was associated with greater acute anatomical remodeling compared to RFA, including more pronounced tissue edema and device compression. These changes resolved over time without compromising device seal or position. Small peri-device leaks (<5 mm) were observed on follow-up CT but not TEE imaging in the pulsed field ablation group only. Further studies are warranted to assess the long-term implications of PFA–associated remodeling and its potential impact on device performance.

CirculationVol. 152(Suppl_3)
Cleveland Clinic (US), Emory Healthcare (US), Boston Scientific (United States) (US), Texas Cardiac Arrhythmia (US), Memorial Hospital (US)
Openalex Percentile: Top 51%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.