Abstract 4346878: Comparison of Intra-coronary and Intra-aortic Pressure Recordings for Coronary Wave Intensity Analysis
Background: Coronary wave intensity analysis (WIA) provides a mechanistic view of coronary hemodynamics and has been increasingly used to phenotype coronary microvascular disease (CMD). Standard WIA requires simultaneous pressure and flow measurements within the same vessel, but intra-coronary pressure measurement may be limited by hardware availability. In patients with non-obstructive coronary arteries, aortic pressure may serve as a surrogate for intra-coronary pressure to enable broader feasibility of WIA. We aimed to determine whether wave profiles derived from intra-aortic and intra-coronary pressure measurements are comparable when paired with intracoronary Doppler flow in patients with non-obstructive coronary artery disease. Methods: Patients undergoing invasive coronary physiology assessment of the left anterior descending artery were included. Intracoronary flow velocity and intra-coronary pressure were simultaneously recorded using a ComboWire (Philips Volcano) in the proximal LAD. Aortic pressure was concurrently measured via the guide catheter to allow comparison of pressure sources. In the intra-aortic pressure group, pressure and flow data were aligned using the R wave of the ECG trace. WIA was performed using conventional methods to quantify the dominant waves: forward compression wave (FCW), backward compression wave (BCW), and backward expansion wave (BEW). Agreement between wave intensity was assessed using Bland-Altman analysis and Pearson correlation. Results: A total of 14 paired waveforms were analyzed with a total of 42 coronary waves compared. Wave intensities calculated using intra-coronary versus intra-aortic pressure showed excellent agreement across all wave types. Mean bias between methods was −0.07 x 10 3 W×m -2 ×s -1 with limits of agreement from −0.63 to +0.49. The correlation between intra-coronary and intra-aortic wave intensities was strong (r = 0.997, p < 0.001), with minimal dispersion and consistent agreement across the full range of wave intensities ( Figure 1 ). Conclusions: In patients with non-obstructive coronary arteries, wave intensity analysis using guide-catheter aortic pressure yields results nearly identical to those obtained with intra-coronary pressure. These findings support the use of aortic pressure as a reliable surrogate for intra-coronary pressure in WIA for the calculation of microvascular coronary hemodynamics, reducing technical barriers and enabling broader clinical and research utilization.
Authors
- Justin Carrington
- Amir Lerman (ORCID: https://orcid.org/0000-0002-9446-5313)
- Abhiram Prasad (ORCID: https://orcid.org/0000-0001-9252-5602)
- Claire E. Raphael (ORCID: https://orcid.org/0000-0002-2206-0413)
- Rajiv Gulati
Institutions
- Mayo Clinic (US)
Publication Details
- Journal
- Circulation
- Published
- 2025-11-03
- DOI
- https://doi.org/10.1161/circ.152.suppl_3.4346878
- Primary Topic
- Cardiovascular Health and Disease Prevention
- Type
- article
- Field-Weighted Citation Impact
- 0.00