Abstract 4370574: Artificial Intelligence-Enabled Electrocardiography Demonstrates Strong Diagnostic Performance for Diastolic Dysfunction, Heart Failure with Preserved Ejection Fraction, and Left Atrial Enlargement: A Meta-Analysis

Introduction: Artificial intelligence (AI)-enabled electrocardiography (ECG) is redefining cardiac diagnostics by uncovering structural and functional abnormalities that human clinicians may not detect. Notably, AI models have shown promise in characterizing left ventricular diastolic dysfunction (LVDD), heart failure with preserved ejection fraction (HFpEF), and left atrial enlargement (LAE). However, the diagnostic performance of these models varies across studies. This meta-analysis evaluates the pooled performance of ECG-based AI models in detecting LVDD, HFpEF, and LAE. Research Question: What is the pooled diagnostic accuracy of AI-enabled ECG models for detecting (1) LVDD, (2) HFpEF, and (3) LAE? Methods: We systematically searched MEDLINE and Embase through May 2025 for studies evaluating AI-based ECG models for the diagnosis of LVDD, HFpEF, or LAE. Studies were included if they reported or allowed derivation of 2×2 confusion matrix data. A bivariate random-effects meta-analysis was conducted to pool sensitivity, specify, and area under the summary receiver operating characteristic (SROC) curve. Heterogeneity was quantified using sample size-adjusted I 2 estimates. Results: ECG-based AI models demonstrated strong diagnostic accuracy for LVDD, HFpEF, and LAE. Seven studies assessed models for detecting LVDD and yielded a pooled sensitivity of 0.82 (95% CI: 0.81–0.84) and a specificity of 0.75 (95% CI: 0.62–0.85), with an area under the SROC curve (AUC) of 0.83. Between-study heterogeneity was minimal, with sample size–adjusted I 2 estimates ranging from 1.5% to 3.1%. For HFpEF, three studies yielded a pooled sensitivity of 0.88 (95% CI: 0.77–0.95) and a specificity of 0.65 (95% CI: 0.42–0.82), with an AUC of 0.86. Between-study heterogeneity was minimal, with sample size–adjusted I 2 estimates ranging from 0.7% to 2.2%. Similarly, for left atrial enlargement (LAE), three studies yielded a pooled sensitivity of 0.83 (95% CI: 0.80–0.85) and a specificity of 0.80 (95% CI: 0.67–0.89), with an AUC of 0.86. Between-study heterogeneity was minimal, with sample size–adjusted I 2 estimated at 1.5%. Conclusion: AI-enabled ECG models demonstrate robust diagnostic performance for detecting LVDD, HFpEF, and LAE, with strong overall accuracy. These findings highlight the potential of AI as a scalable tool to enhance early detection of structural heart disease and support broader adoption of AI-driven screening in clinical practice.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4370574
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4370574: Artificial Intelligence-Enabled Electrocardiography Demonstrates Strong Diagnostic Performance for Diastolic Dysfunction, Heart Failure with Preserved Ejection Fraction, and Left Atrial Enlargement: A Meta-Analysis

Pierce Nelson, Arveen Shokravi, Daniel Shirvani, Anna Mueller et al.
Circulation
ECG Monitoring and Analysis
article

Abstract 4370574: Artificial Intelligence-Enabled Electrocardiography Demonstrates Strong Diagnostic Performance for Diastolic Dysfunction, Heart Failure with Preserved Ejection Fraction, and Left Atrial Enlargement: A Meta-Analysis

Pierce Nelson, Arveen Shokravi, Daniel Shirvani, Anna Mueller, N. Nasibi
article en

Abstract

Introduction: Artificial intelligence (AI)-enabled electrocardiography (ECG) is redefining cardiac diagnostics by uncovering structural and functional abnormalities that human clinicians may not detect. Notably, AI models have shown promise in characterizing left ventricular diastolic dysfunction (LVDD), heart failure with preserved ejection fraction (HFpEF), and left atrial enlargement (LAE). However, the diagnostic performance of these models varies across studies. This meta-analysis evaluates the pooled performance of ECG-based AI models in detecting LVDD, HFpEF, and LAE. Research Question: What is the pooled diagnostic accuracy of AI-enabled ECG models for detecting (1) LVDD, (2) HFpEF, and (3) LAE? Methods: We systematically searched MEDLINE and Embase through May 2025 for studies evaluating AI-based ECG models for the diagnosis of LVDD, HFpEF, or LAE. Studies were included if they reported or allowed derivation of 2×2 confusion matrix data. A bivariate random-effects meta-analysis was conducted to pool sensitivity, specify, and area under the summary receiver operating characteristic (SROC) curve. Heterogeneity was quantified using sample size-adjusted I 2 estimates. Results: ECG-based AI models demonstrated strong diagnostic accuracy for LVDD, HFpEF, and LAE. Seven studies assessed models for detecting LVDD and yielded a pooled sensitivity of 0.82 (95% CI: 0.81–0.84) and a specificity of 0.75 (95% CI: 0.62–0.85), with an area under the SROC curve (AUC) of 0.83. Between-study heterogeneity was minimal, with sample size–adjusted I 2 estimates ranging from 1.5% to 3.1%. For HFpEF, three studies yielded a pooled sensitivity of 0.88 (95% CI: 0.77–0.95) and a specificity of 0.65 (95% CI: 0.42–0.82), with an AUC of 0.86. Between-study heterogeneity was minimal, with sample size–adjusted I 2 estimates ranging from 0.7% to 2.2%. Similarly, for left atrial enlargement (LAE), three studies yielded a pooled sensitivity of 0.83 (95% CI: 0.80–0.85) and a specificity of 0.80 (95% CI: 0.67–0.89), with an AUC of 0.86. Between-study heterogeneity was minimal, with sample size–adjusted I 2 estimated at 1.5%. Conclusion: AI-enabled ECG models demonstrate robust diagnostic performance for detecting LVDD, HFpEF, and LAE, with strong overall accuracy. These findings highlight the potential of AI as a scalable tool to enhance early detection of structural heart disease and support broader adoption of AI-driven screening in clinical practice.

CirculationVol. 152(Suppl_3)
University of British Columbia (CA)
Openalex Percentile: Top 51%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.