Abstract 4362112: Outcomes of Cardiac Implantable Electronic Device-Related Infective Endocarditis (CIED-IE) in Dialysis Patients
Introduction: End-stage kidney disease (ESKD) patients on dialysis are particularly vulnerable to developing cardiac implantable electronic device-related infective endocarditis (CIED-IE), which carries significant morbidity and mortality. Outcomes of these patients are not well known. Research Questions: To compare outcomes of CIED-IE among patients with ESKD, chronic kidney disease (CKD), and those without CKD (no-CKD), using a nationally representative database. Methods: The National Readmission Database (2016–2022) was used to identify patients with CIED-IE using ICD-10-CM codes. Those with prosthetic valves were excluded. Patients were categorized into ESKD, CKD, and no-CKD groups. Results: We identified 22,172 patients hospitalized with CIED-IE: 1,979 (8.9%) with ESKD, 5,573 (25.1%) with CKD, and 12,233 (55.2%) without CKD. ESKD patients were younger (mean age: ESKD 66.3, CKD 76.5, no-CKD 69.9 years; P<0.001) and had a lower proportion of males (ESKD 62.6%, CKD 68.9%, no-CKD 64.1%; P<0.001). ESKD patients had the highest in-hospital mortality (ESKD 16.5%, CKD 12.0%, no-CKD 8.3%; P<0.001) and 3-month post-discharge mortality (ESKD 8.9%, CKD 3.7%, no-CKD 2.4%; P<0.001). The lead extraction rate within 3 months of CIED-IE diagnosis was highest in patients without CKD (no-CKD 24.3%, CKD 20.6%, ESKD 17.6%; P<0.001). ESKD patients also had the highest 3-month readmission rate (ESKD 52.5%, CKD 43.5%, no-CKD 37.7%; P<0.001). Stroke rates were low and showed no significant differences across groups during hospitalization (no-CKD: 0.9%, CKD: 1.2%, ESKD: 1.7%; P=0.0959) or within 3 months post-discharge (no-CKD: 0.9%, CKD: 1.0%, ESKD: 1.1%; P=0.9209). Conclusions: ESKD patients with CIED-IE experienced significantly worse outcomes, including higher in-hospital mortality, post-discharge mortality, and readmission rates, compared to those with CKD or no-CKD. ESKD patients were also the least likely to undergo lead extraction within 3 months of CIED-IE diagnosis. Stroke incidence did not significantly differ between groups during hospitalization or after discharge.
Authors
- Ramya Banda
- Wan‐Chi Chan (ORCID: https://orcid.org/0000-0001-6883-5686)
- Kamal Gupta (ORCID: https://orcid.org/0000-0002-2440-9033)
- Freidy Eid
- H. Mannam (ORCID: https://orcid.org/0000-0003-1359-0612)
- Laiba Sajjad
- Andrew Fancher
- Emmanuel Oundo (ORCID: https://orcid.org/0009-0000-3834-0092)
- Reuben Odai
- Anthony Alchaer
Institutions
- University of Kansas (US)
- The University of Kansas Health System (US)
- Wichita State University (US)
- Wichita Clinic (US)
Publication Details
- Journal
- Circulation
- Published
- 2025-11-03
- DOI
- https://doi.org/10.1161/circ.152.suppl_3.4362112
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00