Abstract 4346922: Neonatal Animal Model of Shunted Single Ventricle Circulation

Introduction/Background: Current knowledge of a Stage 1 shunted single ventricle (SSV) physiology is predominantly based on clinical data. Development of a reliable and reproducible SSV animal model can facilitate pre-clinical research on strategies to improve outcomes. Research Questions/ Hypothesis: We hypothesize that a functional SSV animal model can be created by percutaneously creating a large atrial communication, placing a systemic to pulmonary artery shunt and excluding the right ventricle (RV) from the circulation. Goals/Aims: We aimed to create a neonatal porcine SSV model without using cardiopulmonary bypass. Methods/Approach: Neonatal pigs (n=8; weight 6.1±2.6 kgs) were used. A median sternotomy was performed. A 6-mm ring enforced PTFE graft was anastomosed end-side to the main pulmonary artery (MPA), end-end to the innominate artery and occluded with a vascular clamp. Under epicardial echocardiography guidance, the atrial septum was percutaneously perforated using electrocautery. (Figure 1A). Electrocautery was applied using a coaxial system of 4 Fr JR 3 catheter and a 0.014-inch coronary wire with its denuded tip at the atrial septum. Balloon atrial septostomy was performed using B. Braun Z-5 13.5 mm and/or the Edwards Miller septostomy balloon. To prevent RV distension, a per-ventricular Tricuspid valve (TV) avulsion was done using a Rumel tourniquet guide as a snare placed through a 7 Fr per-ventricular sheath (Figure 1B) . The systemic to pulmonary artery shunt (SPS) was unclamped, and antegrade pulmonary blood (APF) was interrupted by the occlusion of the MPA. Inotropic support was initiated. Donor pig blood was transfused for volume replacement. Hemodynamic and laboratory data were collected. The circulation was maintained for a minimum duration of 1 hour. Results/Data: The SSV was successfully created in 6 out of 8 animals. The SSV circulation had a mean arterial pressure of 37.5±12 mmHg and a common atrial pressure of 12±6 mmHg. The mean aortic flow was 0.76±0.34 L/min, and the systemic to pulmonary artery shunt flow was 0.36±0.23 L/min. The mean Qp/Qs ratio was 1.27±1.14. The systemic saturation was 82±16%, and the mixed venous saturation was 58±17%. Conclusions: A porcine animal model of an SSV circulation can be created without using cardiopulmonary bypass by performing a percutaneous atrial septostomy, per ventricular TV avulsion, placing a SPS and interrupting APF. This model effectively replicates the stage 1 SSV physiology.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4346922
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4346922: Neonatal Animal Model of Shunted Single Ventricle Circulation

Gurumurthy Hiremath, Pranava Sinha, Satoshi Miyairi, Syed Murfad Peer et al.
Circulation
Congenital Heart Disease Studies
article

Abstract 4346922: Neonatal Animal Model of Shunted Single Ventricle Circulation

Gurumurthy Hiremath, Pranava Sinha, Satoshi Miyairi, Syed Murfad Peer, James F. Berry
article en

Abstract

Introduction/Background: Current knowledge of a Stage 1 shunted single ventricle (SSV) physiology is predominantly based on clinical data. Development of a reliable and reproducible SSV animal model can facilitate pre-clinical research on strategies to improve outcomes. Research Questions/ Hypothesis: We hypothesize that a functional SSV animal model can be created by percutaneously creating a large atrial communication, placing a systemic to pulmonary artery shunt and excluding the right ventricle (RV) from the circulation. Goals/Aims: We aimed to create a neonatal porcine SSV model without using cardiopulmonary bypass. Methods/Approach: Neonatal pigs (n=8; weight 6.1±2.6 kgs) were used. A median sternotomy was performed. A 6-mm ring enforced PTFE graft was anastomosed end-side to the main pulmonary artery (MPA), end-end to the innominate artery and occluded with a vascular clamp. Under epicardial echocardiography guidance, the atrial septum was percutaneously perforated using electrocautery. (Figure 1A). Electrocautery was applied using a coaxial system of 4 Fr JR 3 catheter and a 0.014-inch coronary wire with its denuded tip at the atrial septum. Balloon atrial septostomy was performed using B. Braun Z-5 13.5 mm and/or the Edwards Miller septostomy balloon. To prevent RV distension, a per-ventricular Tricuspid valve (TV) avulsion was done using a Rumel tourniquet guide as a snare placed through a 7 Fr per-ventricular sheath (Figure 1B) . The systemic to pulmonary artery shunt (SPS) was unclamped, and antegrade pulmonary blood (APF) was interrupted by the occlusion of the MPA. Inotropic support was initiated. Donor pig blood was transfused for volume replacement. Hemodynamic and laboratory data were collected. The circulation was maintained for a minimum duration of 1 hour. Results/Data: The SSV was successfully created in 6 out of 8 animals. The SSV circulation had a mean arterial pressure of 37.5±12 mmHg and a common atrial pressure of 12±6 mmHg. The mean aortic flow was 0.76±0.34 L/min, and the systemic to pulmonary artery shunt flow was 0.36±0.23 L/min. The mean Qp/Qs ratio was 1.27±1.14. The systemic saturation was 82±16%, and the mixed venous saturation was 58±17%. Conclusions: A porcine animal model of an SSV circulation can be created without using cardiopulmonary bypass by performing a percutaneous atrial septostomy, per ventricular TV avulsion, placing a SPS and interrupting APF. This model effectively replicates the stage 1 SSV physiology.

CirculationVol. 152(Suppl_3)
University of Minnesota System (US), Michigan Manufacturing Technology Center (US)
Openalex Percentile: Top 57%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.