Abstract 4366122: Outcomes of Transcatheter Mitral Repair in Cardiogenic Shock With and Without Mechanical Circulatory Support

Background: Severe mitral regurgitation (MR) in cardiogenic shock (CS) presents unique therapeutic challenges, especially in patients with prohibitive surgical risk. Transcatheter edge-to-edge repair (TEER) with MitraClip offers a less invasive alternative, yet optimal strategies for hemodynamic support in this setting remain unclear. Methods: We conducted a retrospective study of patients undergoing MitraClip implantation for severe MR and CS between 2018 and 2024 at a tertiary academic center. Of 440 screened cases, 47 met CS criteria and were stratified based on receipt of periprocedural Impella support. Clinical, procedural, and survival outcomes were compared between Impella-supported and unsupported cohorts using appropriate statistical methods. Results: Among the 47 patients, 24 received Impella support and 23 did not. The Impella group had greater illness severity, including higher rates of preprocedural intubation (75.0% vs. 43.5%) and SCAI stage D shock (50.0% vs. 13.0%). Despite these differences, procedural success was 100% in both groups. In-hospital (8.3% vs. 8.7%), 30-day (12.5% vs. 8.7%), and 1-year mortality (25.0% vs. 26.0%) were similar between Impella and non-Impella patients, respectively. Impella recipients had longer hospital stays (median 18 vs. 11 days; p=0.032) and higher 1-year readmission rates (55.0% vs. 21.7%; p=0.024), reflecting baseline acuity. There were no differences in major procedural complications or re-intervention rates. Conclusions: MitraClip implantation in CS patients supported with Impella is feasible and safe. Despite significantly worse hemodynamic profiles, outcomes were comparable to those without mechanical support. These findings suggest a potential role for tailored Impella use in expanding TEER to critically ill patients and underscore the need for prospective studies to guide support strategies in high-risk MR intervention.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4366122
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4366122: Outcomes of Transcatheter Mitral Repair in Cardiogenic Shock With and Without Mechanical Circulatory Support

Habib Rahban, Beeletsega T. Yeneneh, Said Alsidawi, Ambar Andrade et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4366122: Outcomes of Transcatheter Mitral Repair in Cardiogenic Shock With and Without Mechanical Circulatory Support

Habib Rahban, Beeletsega T. Yeneneh, Said Alsidawi, Ambar Andrade, Mustafa Suppah, Abeeha Naqvi, Hursh Naik, Pallavi Bellamkonda, Mohsin Sheraz Mughal, Billal Mohmand, Sant Kumar
article en

Abstract

Background: Severe mitral regurgitation (MR) in cardiogenic shock (CS) presents unique therapeutic challenges, especially in patients with prohibitive surgical risk. Transcatheter edge-to-edge repair (TEER) with MitraClip offers a less invasive alternative, yet optimal strategies for hemodynamic support in this setting remain unclear. Methods: We conducted a retrospective study of patients undergoing MitraClip implantation for severe MR and CS between 2018 and 2024 at a tertiary academic center. Of 440 screened cases, 47 met CS criteria and were stratified based on receipt of periprocedural Impella support. Clinical, procedural, and survival outcomes were compared between Impella-supported and unsupported cohorts using appropriate statistical methods. Results: Among the 47 patients, 24 received Impella support and 23 did not. The Impella group had greater illness severity, including higher rates of preprocedural intubation (75.0% vs. 43.5%) and SCAI stage D shock (50.0% vs. 13.0%). Despite these differences, procedural success was 100% in both groups. In-hospital (8.3% vs. 8.7%), 30-day (12.5% vs. 8.7%), and 1-year mortality (25.0% vs. 26.0%) were similar between Impella and non-Impella patients, respectively. Impella recipients had longer hospital stays (median 18 vs. 11 days; p=0.032) and higher 1-year readmission rates (55.0% vs. 21.7%; p=0.024), reflecting baseline acuity. There were no differences in major procedural complications or re-intervention rates. Conclusions: MitraClip implantation in CS patients supported with Impella is feasible and safe. Despite significantly worse hemodynamic profiles, outcomes were comparable to those without mechanical support. These findings suggest a potential role for tailored Impella use in expanding TEER to critically ill patients and underscore the need for prospective studies to guide support strategies in high-risk MR intervention.

CirculationVol. 152(Suppl_3)
Creighton University (US), St. Joseph Hospital (US), Monmouth Medical Center (US), Mayo Clinic Hospital (US), Scottsdale Research Institute (United States) (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.