Abstract 4369244: AI-enabled ECG for Structural Heart Disease Diagnosis Improves Triage of Echocardiography Referral in a Low-Resource Setting: The PROVAR+ Study
Background: Echocardiography is resource-intensive, limiting its use in screening for structural heart diseases (SHD). Broader use of point-of-care ultrasound (POCUS) by trained paramedical staff may improve early SHD detection, but effective patient selection is essential. ECGs may enable triage for POCUS use, with either traditional ECG interpretation for major abnormalities or the use of AI to detect subtle patterns of SHD from ECGs. Aim: To compare the performance of AI vs traditional ECG interpretation for detecting probable SHD on cardiac POCUS. Methods: PROVAR+ is an international collaborative study in Divinopolis, Brazil. In 2023-25, 6,488 consecutive patients who underwent clinical ECGs were centrally adjudicated for presence of major ECG abnormalities based on Minnesota Code criteria. Patients with major abnormalities, along with controls without these abnormalities at a 5:1 ratio, were prospectively enrolled for cardiac POCUS. We compared a validated SHD model (AUROC 0.91 against gold standard SHD diagnosis in multiple cohorts, including ELSA-Brasil) against traditional ECG interpretation for probable SHD on POCUS, defined as LVEF <40%, moderate-to-severe left-sided valve disease, or severe LV hypertrophy. We assessed the relative sensitivity and specificity of each approach, evaluated reclassification performance using net reclassification index (NRI), and examined clinical utility through decision curve analysis. Results: A total of 3,282 patients (67±40y; 48% female, 88% with ECG abnormalities) underwent POCUS, and 567 (17%) had probable SHD. Traditional ECG abnormalities had limited discrimination for probable SHD (AUROC 0.52, PPV 0.18, NPV 0.86). In contrast, AI-ECG had substantially higher performance (AUROC 0.73; PPV 0.29, NPV 0.93 at Youden’s J threshold). Traditional ECG interpretation did not have additive predictive performance with AI-ECG (AUROC, AI-ECG + traditional, 0.73) (A). AI-ECG substantially improved SHD risk classification, with an NRI of 0.35, driven by 46% improvement in correctly downgrading non-events (B). In decision curve analysis (C), AI-ECG had net benefit across a range of clinically relevant decision thresholds (0.05-0.35), outperforming traditional ECG interpretation. Conclusions: AI-ECG significantly optimizes the yield of screening POCUS without such a benefit from traditional ECG interpretation. It reduces false positives and can improve the role of large-scale screening for SHD in resource-constrained settings.
Authors
- Bruno Nascimento (ORCID: https://orcid.org/0000-0003-4319-4434)
- Rohan Khera (ORCID: https://orcid.org/0000-0001-9467-6199)
- Aline F Pedroso (ORCID: https://orcid.org/0000-0002-1876-8304)
- António Bettencourt Ribeiro (ORCID: https://orcid.org/0000-0002-7618-5297)
- Luísa Campos Caldeira Brant (ORCID: https://orcid.org/0000-0002-7317-1367)
- Craig Sable (ORCID: https://orcid.org/0000-0002-6798-2737)
- Lovedeep Dhingra
- Gabriela Paixão (ORCID: https://orcid.org/0000-0003-1349-1745)
- Sumukh Vasisht Shankar (ORCID: https://orcid.org/0009-0005-3034-0641)
- Clara Oliveira
Institutions
- Universidade Federal de Minas Gerais (BR)
- Yale University (US)
- Children's Hospital of New Orleans (US)
Publication Details
- Journal
- Circulation
- Published
- 2025-11-03
- DOI
- https://doi.org/10.1161/circ.152.suppl_3.4369244
- Citations
- 1
- Primary Topic
- Ultrasound in Clinical Applications
- Type
- article
- Field-Weighted Citation Impact
- 1.55