Abstract Sun805: Relationship between ventriculoarterial coupling and hemodynamics using active decompression and impedance threshold device during automated head-up CPR
Background: Ventriculo-arterial (VA) coupling characterizes the interaction between the cardiac function and the arterial circulation afterload and reflects cardiovascular performance. We found, for the first time, that there is a significant VA decoupling with conventional CPR, which was ameliorated by automated head-up (AHUP)-CPR using active compression-decompression (ACD), impedance threshold device (ITD) as well as head and thorax elevation. Research Questions: How does the degree of active decompression (AD) influence VA coupling and its association with hemodynamic and perfusion outcomes during AHUP-CPR? Methods: Farm pigs (~40 kg) were intubated, ventilated, and monitored for hemodynamics, including end-tidal CO2 (ETCO2), and pressure-volume loops in right (RV | n=10) and left (LV | n =4) ventricles. After 10 minutes of untreated ventricular fibrillation, CPR started with 2 minutes each of C-CPR, ACD+ITD, and AHUP-CPR at 3 cm elevation. At minute 15, AD was paused, then resumed incrementally up to 4 cm. Statistical analysis was performed using a mixed-effects model to evaluate the effects of incremental AD on VA coupling, and a Spearman correlation to explore the relationship between VA coupling and hemodynamics. Results: Full AD (3cm or more) resulted in significantly enhanced VA coupling compared to no AD (p<0.05 in both ventricles) or minimal AD (1cm | p<0.05 RV and p=0.24 LV). Improved RV and LV VA coupling with full AD was associated with higher SV in both ventricles, as well as higher aortic pressures, and coronary and cerebral perfusions (table 1 and figure 1). Optimized VA coupling was also correlated with enhanced compression efficiency, which led to end compression volumes as a result of more efficient cardiac output. Conclusion: Full AD (3cm or more) when used with ITD during AHUP-CPR leads to optimal VA circulation. Optimized VA coupling in both ventricles resulted in enhanced cardiac filling and output, and subsequently, increased systemic, coronary and cerebral perfusion pressures. RV showed a different pattern to LV, likely due to its different load and contractile efficiency.
Authors
- Anja Metzger
- Johanna Moore (ORCID: https://orcid.org/0000-0001-5029-6426)
- Mithun Suresh
- Nicolas Segond (ORCID: https://orcid.org/0000-0002-1049-9816)
- Bayert Salverda
- Keith G. Lurie
- Pouria Poorzand
Institutions
- University of Minnesota (US)
- Fairview Health Services (US)
- Centre Hospitalier Universitaire de Grenoble (FR)
- Hennepin County Medical Center (US)
- Lehigh Valley Health Network (US)
- Hennepin Healthcare Research Institute (US)
Publication Details
- Journal
- Circulation
- Published
- 2025-11-03
- DOI
- https://doi.org/10.1161/circ.152.suppl_3.sun805
- Primary Topic
- Cardiac Arrest and Resuscitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00