Abstract Or105: <i>“If it Can Help Someone, Then They Want to Do It”:</i> Demonstrating Feasibility of End-of-Life Studies to Support Development and Validation of Cardiac Arrest Detection Technologies with Consumer Smartwatches

INTRO: Most out-of-hospital cardiac arrest (OHCA) cases are unwitnessed, leading to poor survival. Wearable devices have been proposed to notify first responders that an OHCA has occurred. However, there are currently no systems that have been validated using real cardiac arrest data. To address this gap, we conducted an observational clinical trial in end-of-life settings to collect data on natural and induced cardiac arrest using wearable technologies. Methods: We recruited individuals across Canada undergoing Medical Assistance In Dying (MAID) procedures, as well as patients in hospice settings. Participants received a consumer grade study watch that collected raw photoplethysmography (PPG) data corresponding to blood volume changes. We completed an interim analysis to describe the cohort, reasons for participation, and assess the feasibility of using this data for algorithm development. We plotted raw PPG values for each participant and used clinical event timelines (time of MAID medication administration, time of respiratory arrest, time of clinician confirmed death) to classify recordings as pulsatile, transitory, or pulseless. Results: From May 1, 2024, to May 1, 2025, 64 individuals were enrolled. 53 met the primary outcome of death while wearing the study watch (82.8%, Table 1). In the MAID arm, all but one case was identified by the same clinician who approached all their community patients during the study period with 34/36 (94.4%) consenting. In the hospice arm, 30/186 (16.1%) patients across three study sites consented. 6 (20%) hospice patients withdrew due to watch discomfort and 5 (16.7%) patients did not wear the watch at time of death. Participants reported an interest in giving back and helping science as motivations for participation (Table 2). Data was successfully obtained from all participants who wore the watch at the time of death. A loss of pulsatile activity was observed for participants that corresponded to clinical event timelines (Figure 1). Conclusion: Wearable-based research in end-of-life settings was feasible and yielded useful data. A clinician advocate was essential for high patient opt-in in the MAID arm. Watch discomfort was a barrier to study continuation in the hospice arm, as the duration of device wear was often several weeks. Ongoing work to train models for cardiac arrest detection is supported by the diversity of this large dataset of pulsatile and pulseless recordings from natural and induced cardiac arrest.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.or105
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract Or105: “If it Can Help Someone, Then They Want to Do It”: Demonstrating Feasibility of End-of-Life Studies to Support Development and Validation of Cardiac Arrest Detection Technologies with Consumer Smartwatches

Jacob Hutton, Babak Shadgan, Katie Dainty, Jim Christenson et al.
Circulation
Cardiac Arrest and Resuscitation
article

Abstract Or105: “If it Can Help Someone, Then They Want to Do It”: Demonstrating Feasibility of End-of-Life Studies to Support Development and Validation of Cardiac Arrest Detection Technologies with Consumer Smartwatches

Jacob Hutton, Babak Shadgan, Katie Dainty, Jim Christenson, Mypinder S. Sekhon, Zahra Askari, Laurie J. Morrison, Mehdi Nourizadeh, Mahsa Khalili, Brian Grunau, Saud Lingawi, Calvin Kuo
article en

Abstract

INTRO: Most out-of-hospital cardiac arrest (OHCA) cases are unwitnessed, leading to poor survival. Wearable devices have been proposed to notify first responders that an OHCA has occurred. However, there are currently no systems that have been validated using real cardiac arrest data. To address this gap, we conducted an observational clinical trial in end-of-life settings to collect data on natural and induced cardiac arrest using wearable technologies. Methods: We recruited individuals across Canada undergoing Medical Assistance In Dying (MAID) procedures, as well as patients in hospice settings. Participants received a consumer grade study watch that collected raw photoplethysmography (PPG) data corresponding to blood volume changes. We completed an interim analysis to describe the cohort, reasons for participation, and assess the feasibility of using this data for algorithm development. We plotted raw PPG values for each participant and used clinical event timelines (time of MAID medication administration, time of respiratory arrest, time of clinician confirmed death) to classify recordings as pulsatile, transitory, or pulseless. Results: From May 1, 2024, to May 1, 2025, 64 individuals were enrolled. 53 met the primary outcome of death while wearing the study watch (82.8%, Table 1). In the MAID arm, all but one case was identified by the same clinician who approached all their community patients during the study period with 34/36 (94.4%) consenting. In the hospice arm, 30/186 (16.1%) patients across three study sites consented. 6 (20%) hospice patients withdrew due to watch discomfort and 5 (16.7%) patients did not wear the watch at time of death. Participants reported an interest in giving back and helping science as motivations for participation (Table 2). Data was successfully obtained from all participants who wore the watch at the time of death. A loss of pulsatile activity was observed for participants that corresponded to clinical event timelines (Figure 1). Conclusion: Wearable-based research in end-of-life settings was feasible and yielded useful data. A clinician advocate was essential for high patient opt-in in the MAID arm. Watch discomfort was a barrier to study continuation in the hospice arm, as the duration of device wear was often several weeks. Ongoing work to train models for cardiac arrest detection is supported by the diversity of this large dataset of pulsatile and pulseless recordings from natural and induced cardiac arrest.

CirculationVol. 152(Suppl_3)
University of British Columbia (CA), University of Toronto (CA), Trinity Western University (CA), North York General Hospital (CA)
Openalex Percentile: Top 53%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.