Abstract 4357653: Impact of Transition from Micra VR to Micra AV on Heart Failure Hospitalizations in Patients with Atrioventricular Block

Background: Leadless pacemaker provides clinical advantages over traditional transvenous systems, including reduced risk of infections, thromboembolism, and lead-related complications, all of which adversely affect patient safety and quality of life. Recent advancement in the transition from VVI to VDD mode in leadless pacemaker is theoretically advantageous, as atrioventricular (AV) synchronization may enhance hemodynamic performance and alleviate symptoms of heart failure. However, the clinical impact of this mode transition has not systematically studied. Methods: This retrospective cohort study analyzed 133 consecutive patients (mean age: 85.6±6.5 years old, male: 54%, transition from VVI to VDD mode [Micra VR]: 63.9%) who diagnosed with AV block and underwent de novo implantation of leadless pacemakers between September 2017 and March 2024. The outcome measure was heart failure hospitalizations. Multivariate analyses were performed to identify factors associated with heart failure hospitalization within 3 years. Results: The follow-up periods were 323 days (interquartile range [IQR]: 132–613) for the Micra VR group and 392 days (IQR: 266–620) for the Micra AV group, statistically significant difference observed. Both groups had comparable patient backgrounds, with no significant differences in notable risk factors including age, sex, history of heart failure, presence of atrial fibrillation (AF), diabetes, or chronic kidney disease. The Kaplan-Meier analysis revealed that patients with Micra VR had a significantly higher rate of heart failure hospitalizations compared to those with Micra AV (Log Rank, p =0.037). Multivariate analysis showed that Micra VR (HR, 3.22; 95% CI, 1.15-8.98; P =0.026) and history of AF (HR, 5.69; 95% CI, 2.00-16.2; P =0.001) were significantly associated with heart failure hospitalization. Conclusion: The current study revealed that the transition from Micra VR to Micra AV was significantly associated with a reduced risk of heart failure hospitalizations compared to Micra VR over a follow-up period of up to 3 years, potentially due to improved atrioventricular synchrony.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4357653
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4357653: Impact of Transition from Micra VR to Micra AV on Heart Failure Hospitalizations in Patients with Atrioventricular Block

Mikiko Matsumura, Takashi Kanda, Osamu Iida, Hitoshi Minamiguchi et al.
Circulation
Cardiac pacing and defibrillation studies
article

Abstract 4357653: Impact of Transition from Micra VR to Micra AV on Heart Failure Hospitalizations in Patients with Atrioventricular Block

Mikiko Matsumura, Takashi Kanda, Osamu Iida, Hitoshi Minamiguchi, Yasuhiro Ichibori, Takashige Sakio, Kei Nakamoto, Naoki Mori, Yuki Shibuya
article en

Abstract

Background: Leadless pacemaker provides clinical advantages over traditional transvenous systems, including reduced risk of infections, thromboembolism, and lead-related complications, all of which adversely affect patient safety and quality of life. Recent advancement in the transition from VVI to VDD mode in leadless pacemaker is theoretically advantageous, as atrioventricular (AV) synchronization may enhance hemodynamic performance and alleviate symptoms of heart failure. However, the clinical impact of this mode transition has not systematically studied. Methods: This retrospective cohort study analyzed 133 consecutive patients (mean age: 85.6±6.5 years old, male: 54%, transition from VVI to VDD mode [Micra VR]: 63.9%) who diagnosed with AV block and underwent de novo implantation of leadless pacemakers between September 2017 and March 2024. The outcome measure was heart failure hospitalizations. Multivariate analyses were performed to identify factors associated with heart failure hospitalization within 3 years. Results: The follow-up periods were 323 days (interquartile range [IQR]: 132–613) for the Micra VR group and 392 days (IQR: 266–620) for the Micra AV group, statistically significant difference observed. Both groups had comparable patient backgrounds, with no significant differences in notable risk factors including age, sex, history of heart failure, presence of atrial fibrillation (AF), diabetes, or chronic kidney disease. The Kaplan-Meier analysis revealed that patients with Micra VR had a significantly higher rate of heart failure hospitalizations compared to those with Micra AV (Log Rank, p =0.037). Multivariate analysis showed that Micra VR (HR, 3.22; 95% CI, 1.15-8.98; P =0.026) and history of AF (HR, 5.69; 95% CI, 2.00-16.2; P =0.001) were significantly associated with heart failure hospitalization. Conclusion: The current study revealed that the transition from Micra VR to Micra AV was significantly associated with a reduced risk of heart failure hospitalizations compared to Micra VR over a follow-up period of up to 3 years, potentially due to improved atrioventricular synchrony.

CirculationVol. 152(Suppl_3)
Osaka Hospital (JP), Osaka University Hospital (JP)
Openalex Percentile: Top 52%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.