Abstract 4369682: Association Between Microbubble Formation During Pulsed-Field Ablation and Asymptomatic Cerebral Infarction

Background: Pulsed-field ablation (PFA) has been introduced as a non-thermal energy source for atrial fibrillation (AF) ablation. However, a safety alert regarding cerebral infarctions with the VARIPULSE system has raised concerns about the risk of stroke. Additionally, microbubble formation during PFA has been reported in animal models, suggesting a possible link to cerebral infarction. Objective: To determine the frequency of microbubble formation during PFA in real-world practice and investigate its association with asymptomatic cerebral infarctions (ACIs). Methods: We analyzed 31 patients with AF who underwent PFA using either the FARAPULSE or PulseSelect system. Microbubble formation was assessed by intracardiac echocardiography in the aortic arch and right brachiocephalic artery during each PFA application. Bubbles were graded on a 0–3 scale (none to severe). A total microbubble score was calculated for each patient as the sum of the products of bubble grade and frequency. Brain MRI was performed ~24 hours after ablation. The association between this score and ACI was evaluated. Results: The mean age was 68.3 ± 10.1 years, and 23 patients were male. Nineteen had paroxysmal AF, and 12 had persistent AF. The mean number of PFA applications was 39.0 ± 6.1 per patient, with no significant difference between the FARAPULSE and PulseSelect groups. Microbubbles were observed in 492 of 1,209 PFA applications, significantly more frequent with PulseSelect than with FARAPULSE (64.2% vs. 22.4%, p < 0.001). Brain MRI was performed in 21 patients (9 FARAPULSE, 12 PulseSelect), detecting 13 ACIs—4 in FARAPULSE and 9 in PulseSelect (not statistically significant). Among patients with persistent AF, ACIs were seen in 6 of 8 cases; in paroxysmal AF, in 7 of 13 cases (p = 0.64). The number of PFA applications was not associated with ACI occurrence (p = 0.916). However, a higher total microbubble score was significantly correlated with ACI presence (p = 0.002). No symptomatic strokes occurred. Conclusion: Microbubbles were frequently observed during PFA, particularly with the PulseSelect system compared to FARAPULSE. However, there was no significant difference in the incidence of ACI between the two systems. A significant correlation was observed between the total microbubble score and the occurrence of ACI.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4369682
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4369682: Association Between Microbubble Formation During Pulsed-Field Ablation and Asymptomatic Cerebral Infarction

Masaki Ieda, Yoshinori Katsumata, Seiji Yano, Koki Yamaoka et al.
Circulation
Atrial Fibrillation Management and Outcomes
article

Abstract 4369682: Association Between Microbubble Formation During Pulsed-Field Ablation and Asymptomatic Cerebral Infarction

Masaki Ieda, Yoshinori Katsumata, Seiji Yano, Koki Yamaoka, Kohei Sasajima, Yukihiro Himeno, Seiji Takatsuki, Takahiko Nishiyama, Takehiro Kimura, Shuhei Yamashita, Shun Yamanaka, Taiki Kotajima
article en

Abstract

Background: Pulsed-field ablation (PFA) has been introduced as a non-thermal energy source for atrial fibrillation (AF) ablation. However, a safety alert regarding cerebral infarctions with the VARIPULSE system has raised concerns about the risk of stroke. Additionally, microbubble formation during PFA has been reported in animal models, suggesting a possible link to cerebral infarction. Objective: To determine the frequency of microbubble formation during PFA in real-world practice and investigate its association with asymptomatic cerebral infarctions (ACIs). Methods: We analyzed 31 patients with AF who underwent PFA using either the FARAPULSE or PulseSelect system. Microbubble formation was assessed by intracardiac echocardiography in the aortic arch and right brachiocephalic artery during each PFA application. Bubbles were graded on a 0–3 scale (none to severe). A total microbubble score was calculated for each patient as the sum of the products of bubble grade and frequency. Brain MRI was performed ~24 hours after ablation. The association between this score and ACI was evaluated. Results: The mean age was 68.3 ± 10.1 years, and 23 patients were male. Nineteen had paroxysmal AF, and 12 had persistent AF. The mean number of PFA applications was 39.0 ± 6.1 per patient, with no significant difference between the FARAPULSE and PulseSelect groups. Microbubbles were observed in 492 of 1,209 PFA applications, significantly more frequent with PulseSelect than with FARAPULSE (64.2% vs. 22.4%, p < 0.001). Brain MRI was performed in 21 patients (9 FARAPULSE, 12 PulseSelect), detecting 13 ACIs—4 in FARAPULSE and 9 in PulseSelect (not statistically significant). Among patients with persistent AF, ACIs were seen in 6 of 8 cases; in paroxysmal AF, in 7 of 13 cases (p = 0.64). The number of PFA applications was not associated with ACI occurrence (p = 0.916). However, a higher total microbubble score was significantly correlated with ACI presence (p = 0.002). No symptomatic strokes occurred. Conclusion: Microbubbles were frequently observed during PFA, particularly with the PulseSelect system compared to FARAPULSE. However, there was no significant difference in the incidence of ACI between the two systems. A significant correlation was observed between the total microbubble score and the occurrence of ACI.

CirculationVol. 152(Suppl_3)
Keio University (JP), Keio University Hospital (JP)
Openalex Percentile: Top 52%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.