Abstract 4368476: Total Support by a Trans-Aortic Valve Micro-Axial Flow Pump Reduces Coronary Blood Flow in Both Normal and Post-reperfusion Coronary Arteries in a Goat Model of Ischemia-Reperfusion

Introduction: In cases of cardiogenic shock, the transaortic micro-axial flow pump (Impella) improves systemic circulation and increases coronary perfusion pressure (CPP) while reducing myocardial oxygen consumption (MVO 2 ) via its left ventricular (LV) unloading effect. The Impella 5.5, in particular, enables stronger LV unloading due to its higher flow capacity. Physiologically, coronary blood flow (CBF) increases with CPP, while reduced MVO 2 may activate autoregulatory mechanisms that limit CBF. Hypothesis: We hypothesized that a marked reduction in MVO 2 by the Impella 5.5 may attenuate CBF. This study evaluates the impact of Impella 5.5 support on CBF in normal and post-reperfusion coronary arteries using a goat model of ischemia-reperfusion. Methods: Saanen goats (N=8, BW: 61.6±4.5 kg) were used under general anesthesia. The Impella 5.5 was inserted via the carotid artery into the LV. We measured blood pressure, LV pressure, pulmonary artery flow, arterial and coronary sinus oxygen saturation, and CBF in the left anterior descending artery (LAD) and left circumflex artery (LCX). We occluded the proximal LAD with a 3 mm balloon for 90 minutes, then deflated for reperfusion (Fig. A). At 30-min after reperfusion, Impella support was set at three stages: Control (P1), Partial support with residual native cardiac output (P3-7), and Total support (P6-9). Results: Increasing Impella support augmented CPP (37.8 ± 10.6 vs. 47.1 ± 8.5 vs. 75.2 ± 12.7 mmHg, P < 0.05) and reduced MVO 2 (298.3 ± 161.0 vs. 257.9 ± 122.2 vs. 161.0 ± 121.6, P < 0.05) (Fig. B). Total support with the Impella 5.5 suppressed MVO 2 by 53.0 ± 18.8% compared to the Control condition. LCX flow decreased with increasing Impella support (46.9 ± 26.6 vs. 45.0 ± 28.5 vs. 37.8 ± 31.0 mL/min, P < 0.05). Similarly, LAD flow was significantly reduced under Total support (30.9 ± 11.4 vs. 28.5 ± 11.7 vs. 23.7 ± 12.2 mL/min, P < 0.05) (Fig. C). Conclusion: In a goat model of ischemia–reperfusion, total support with the Impella 5.5 reduced CBF in both the normal LCX and the injured LAD. These results may be influenced by factors such as the severity of coronary injury, the timing of measurement, and the specific animal model used. Nevertheless, the findings suggest that autoregulatory mechanisms triggered by suppressed MVO 2 play a critical role in determining CBF, even in post-reperfusion setting, and should be carefully considered when evaluating the effects of Impella5.5 support on coronary circulation.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4368476
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4368476: Total Support by a Trans-Aortic Valve Micro-Axial Flow Pump Reduces Coronary Blood Flow in Both Normal and Post-reperfusion Coronary Arteries in a Goat Model of Ischemia-Reperfusion

Toru Kawada, Hidetaka Morita, Keita Saku, Masafumi Fukumitsu et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4368476: Total Support by a Trans-Aortic Valve Micro-Axial Flow Pump Reduces Coronary Blood Flow in Both Normal and Post-reperfusion Coronary Arteries in a Goat Model of Ischemia-Reperfusion

Toru Kawada, Hidetaka Morita, Keita Saku, Masafumi Fukumitsu, Kojiro Ohba, Takuya Nishikawa, Yuki Yoshida, Nana Hiraki, Masahiro Otake, Kei Sato, Kazunori Uemura
article en

Abstract

Introduction: In cases of cardiogenic shock, the transaortic micro-axial flow pump (Impella) improves systemic circulation and increases coronary perfusion pressure (CPP) while reducing myocardial oxygen consumption (MVO 2 ) via its left ventricular (LV) unloading effect. The Impella 5.5, in particular, enables stronger LV unloading due to its higher flow capacity. Physiologically, coronary blood flow (CBF) increases with CPP, while reduced MVO 2 may activate autoregulatory mechanisms that limit CBF. Hypothesis: We hypothesized that a marked reduction in MVO 2 by the Impella 5.5 may attenuate CBF. This study evaluates the impact of Impella 5.5 support on CBF in normal and post-reperfusion coronary arteries using a goat model of ischemia-reperfusion. Methods: Saanen goats (N=8, BW: 61.6±4.5 kg) were used under general anesthesia. The Impella 5.5 was inserted via the carotid artery into the LV. We measured blood pressure, LV pressure, pulmonary artery flow, arterial and coronary sinus oxygen saturation, and CBF in the left anterior descending artery (LAD) and left circumflex artery (LCX). We occluded the proximal LAD with a 3 mm balloon for 90 minutes, then deflated for reperfusion (Fig. A). At 30-min after reperfusion, Impella support was set at three stages: Control (P1), Partial support with residual native cardiac output (P3-7), and Total support (P6-9). Results: Increasing Impella support augmented CPP (37.8 ± 10.6 vs. 47.1 ± 8.5 vs. 75.2 ± 12.7 mmHg, P < 0.05) and reduced MVO 2 (298.3 ± 161.0 vs. 257.9 ± 122.2 vs. 161.0 ± 121.6, P < 0.05) (Fig. B). Total support with the Impella 5.5 suppressed MVO 2 by 53.0 ± 18.8% compared to the Control condition. LCX flow decreased with increasing Impella support (46.9 ± 26.6 vs. 45.0 ± 28.5 vs. 37.8 ± 31.0 mL/min, P < 0.05). Similarly, LAD flow was significantly reduced under Total support (30.9 ± 11.4 vs. 28.5 ± 11.7 vs. 23.7 ± 12.2 mL/min, P < 0.05) (Fig. C). Conclusion: In a goat model of ischemia–reperfusion, total support with the Impella 5.5 reduced CBF in both the normal LCX and the injured LAD. These results may be influenced by factors such as the severity of coronary injury, the timing of measurement, and the specific animal model used. Nevertheless, the findings suggest that autoregulatory mechanisms triggered by suppressed MVO 2 play a critical role in determining CBF, even in post-reperfusion setting, and should be carefully considered when evaluating the effects of Impella5.5 support on coronary circulation.

CirculationVol. 152(Suppl_3)
National Cerebral and Cardiovascular Center (JP)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.