Abstract 4365395: Comparison of Echocardiographic Pulmonary Artery Pressures to Pulmonary Artery Catheter Pulmonary Pressures in Patients on Peripheral VA-ECMO in an Academic Tertiary Care Hospital

Introduction: In patients requiring extracorporeal membrane oxygenation (ECMO), monitoring pulmonary artery systolic pressure (PASP) and assessing right ventricular (RV) function is crucial for guiding management. While transthoracic echocardiography offers noninvasive estimation of PASP (ePASP), its accuracy is not validated in ECMO patients. Direct pressure transduction is the gold standard for measuring true PASP (tPASP); however, its use carries risks, including infection, thrombosis, and mechanical complications. Given the invasive nature of PAC placement, an accurate noninvasive alternative could significantly reduce patient morbidity. Methods: This is a retrospective observational study of patients who underwent peripheral VA-ECMO and received an echocardiogram, at MedStar Washington Hospital Center, between 1 January 2014 to 31 December 2024. Patients were included if they had an echocardiogram estimated PASP measurement within 1 hour of a directly transduced pressure measurement while on peripheral VA-ECMO. Exclusion criteria included patients on central VA-ECMO or VV-ECMO, insufficient TR jet to calculate PASP and patients with measurements more than 1 hour apart. Outcomes were modeled with R for statistical computing, using a spearman’s rank correlation, a mixed linear model. Results: 51 patients met study inclusion criteria. From the spearman’s rank correlation model, there was a strong positive correlation between ePASP and tPASP (ρ=0.73, p <0.001). In a linear mixed-effects model, ePASP was significantly associated with tPASP (β=0.81, 95% CI:0.64-0.98, p <0.001), with a marginal R 2 =0.647 and conditional R 2 =0.998. There was no correlation between the ECMO flow rate and ΔPASP, defined as ePASP - tPASP. Discussion: This retrospective observational study demonstrates a positive correlation between ePASP and tPASP in patients on VA-ECMO. The model demonstrated excellent fit, with R 2 values suggesting that both fixed and random effects accounted for nearly all observed variability. Our data suggest echocardiographic estimation of PASP remains accurate irrespective of ECMO flow rate. Future research is warranted to support broader adoption of echocardiography for hemodynamic assessment in VA-ECMO patients. Validating the reliability of echocardiographic estimates could support broader adoption of echocardiography for hemodynamic assessment in ECMO patients, minimizing the need for invasive monitoring and its associated risks.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4365395
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4365395: Comparison of Echocardiographic Pulmonary Artery Pressures to Pulmonary Artery Catheter Pulmonary Pressures in Patients on Peripheral VA-ECMO in an Academic Tertiary Care Hospital

Marc El Khoury, Shriya Khurana, S Abhishek, Trevor Wyand et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4365395: Comparison of Echocardiographic Pulmonary Artery Pressures to Pulmonary Artery Catheter Pulmonary Pressures in Patients on Peripheral VA-ECMO in an Academic Tertiary Care Hospital

Marc El Khoury, Shriya Khurana, S Abhishek, Trevor Wyand, Maxwell A. Hockstein
article en

Abstract

Introduction: In patients requiring extracorporeal membrane oxygenation (ECMO), monitoring pulmonary artery systolic pressure (PASP) and assessing right ventricular (RV) function is crucial for guiding management. While transthoracic echocardiography offers noninvasive estimation of PASP (ePASP), its accuracy is not validated in ECMO patients. Direct pressure transduction is the gold standard for measuring true PASP (tPASP); however, its use carries risks, including infection, thrombosis, and mechanical complications. Given the invasive nature of PAC placement, an accurate noninvasive alternative could significantly reduce patient morbidity. Methods: This is a retrospective observational study of patients who underwent peripheral VA-ECMO and received an echocardiogram, at MedStar Washington Hospital Center, between 1 January 2014 to 31 December 2024. Patients were included if they had an echocardiogram estimated PASP measurement within 1 hour of a directly transduced pressure measurement while on peripheral VA-ECMO. Exclusion criteria included patients on central VA-ECMO or VV-ECMO, insufficient TR jet to calculate PASP and patients with measurements more than 1 hour apart. Outcomes were modeled with R for statistical computing, using a spearman’s rank correlation, a mixed linear model. Results: 51 patients met study inclusion criteria. From the spearman’s rank correlation model, there was a strong positive correlation between ePASP and tPASP (ρ=0.73, p <0.001). In a linear mixed-effects model, ePASP was significantly associated with tPASP (β=0.81, 95% CI:0.64-0.98, p <0.001), with a marginal R 2 =0.647 and conditional R 2 =0.998. There was no correlation between the ECMO flow rate and ΔPASP, defined as ePASP - tPASP. Discussion: This retrospective observational study demonstrates a positive correlation between ePASP and tPASP in patients on VA-ECMO. The model demonstrated excellent fit, with R 2 values suggesting that both fixed and random effects accounted for nearly all observed variability. Our data suggest echocardiographic estimation of PASP remains accurate irrespective of ECMO flow rate. Future research is warranted to support broader adoption of echocardiography for hemodynamic assessment in VA-ECMO patients. Validating the reliability of echocardiographic estimates could support broader adoption of echocardiography for hemodynamic assessment in ECMO patients, minimizing the need for invasive monitoring and its associated risks.

CirculationVol. 152(Suppl_3)
MedStar Washington Hospital Center (US), MedStar Georgetown University Hospital (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.